SAFETY-128: control does not act on late Home Assistant readings
Readings that Home Assistant delivers late but still changing passed every staleness gate, so the loop corrected again each cycle an error its last command had already fixed (10 s late: the give run swung and exported to -1.9 kW), and the peak guard pushed to the inverter limit on the same late figures (OPT-34 F-2). app/lateness.py fits how long after a power request the meter shows it. Over 8 s the readings are late: a request the battery reading has not answered holds the loop (it may not lead the reading by more than 100 W) and caps the peak guard at what stands; unanswered for 23 s it holds, then 0 W after stale_input_s. An amber row and one log line per episode say so. With readings on time nothing changes (digests equal). DECISIONS/SAFETY-128-late-readings.md; test_safety128.py. Co-Authored-By: Claude <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC