SAFETY-42 round 2: pin the two thresholds at a config that is not the shipped one
checks / unit (pull_request) Successful in 6m7s
checks / unit (pull_request) Successful in 6m7s
THE BLOCKER. At the `delinquent()` call site, `self.tuning.saturation_w` -> `250.0` (-19 B) was a survivor of all 23 suites. It is not an equivalent mutant: two copies of inverter A, B wedged, `saturation_w: 1800` (inside its own schema int(100,2000)) and a load of 1600 W put B's shortfall strictly between the literal and the configured value - head names nobody, the mutant names B. At the shipped 500 both name it, which is exactly why every fixture in part 4 was blind: their gaps are all above both thresholds. It matters beyond a mutation score. `delivery.py`'s MIN_W_IS_SATURATION_W note and the `delivery_hold_s` block in config.yaml both promise an operator, in shipped prose, that there is no fourth copy of a threshold to keep in step and no way for the two to drift - raise `saturation_w` and this check moves with you. A literal at the call site removes exactly that promise, silently, and the promise is why the design was chosen over a `delivery_w` key. ASKING THE SAME QUESTION OF EVERY OTHER NUMBER THIS CHECK READS FOUND A SECOND SURVIVOR OF ALL 23 SUITES: `bms_floor=inv.bms_soc_floor` -> `10.0` (-13 B), invisible because config.yaml's own example states 10 % and every fixture in this file used it. Two arms bracket it: a pack at 15 % against its own 25 % cut-out is cold and must stay unnamed (the literal names an empty pack), and a pack at 8 % against its own 5 % cut-out is wedged and must be named (the literal explains the fault away). One arm on each side leaves no constant at all. `delivery_hold_s` and `is_live()`'s window were ALREADY pinned - the fixtures had to move them to run - and `LINK_STALE_S` has no option behind it, so "pinned across a changed config" is not available for it and is not claimed. DECISIONS section 9 enumerates all of it with the deltas and which check kills which. Verified in the CI image, tree mounted :ro, `python3 -B`, `__pycache__` purged and counted before every run (TEST-15): R5 saturation_w -> 250.0 -19 B killed by part 4b(a) R6 bms_soc_floor -> 10.0 -13 B killed by part 4b(b), both arms R7 arm(self.delivery_cfg) -> DeliveryConfig() -1 B killed (already) R8 is_live(now) -> is_live(now, 3600.0) +8 B killed (already) R9 pack cut-out -> conjoined site floor +105 B killed twice head: 23/23 test files PASS, no bytecode written during the run. No shipped behaviour changes: the only edits to app/ are comments. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
@@ -10,6 +10,14 @@ target, per-unit share, per-unit measured power), to the last emitted watt. If
|
||||
this file's two fixtures ever stop differing, the check has stopped being
|
||||
graded on the only thing that separates the two cases.
|
||||
|
||||
⚠️ AND PART 4b IS THE OTHER HALF OF THE SAME LESSON, ONE LEVEL UP. Part 4 shows
|
||||
that no threshold on the power domain can separate the two cases; part 4b shows
|
||||
that a check which only ever runs at the SHIPPED value of a threshold cannot
|
||||
separate "this call site reads the operator's config" from "this call site has a
|
||||
number typed into it". Both are the same defect - a fixture whose values cannot
|
||||
reach the failure it names - and the second one hid two literals from all 23
|
||||
suites in this repository.
|
||||
|
||||
⚠️ MUTATING THE MODULE THIS FILE GRADES? PURGE `__pycache__` FIRST - or run
|
||||
`tools/mutation_run.sh`, which does. `python3 -B` alone does NOT save you: it
|
||||
stops bytecode being WRITTEN, not a stale one being READ. That is TEST-15, and
|
||||
@@ -349,14 +357,24 @@ class _DeliveryHass:
|
||||
return True
|
||||
|
||||
|
||||
def _roster():
|
||||
def _roster(floors=(_FLOOR_PCT, _FLOOR_PCT)):
|
||||
"""The two-unit roster. `floors` is (A's own cut-out, B's own cut-out).
|
||||
|
||||
⚠️ IT IS AN ARGUMENT RATHER THAN `_FLOOR_PCT` TWICE, AND THAT IS HALF OF
|
||||
PART 4b. Every fixture in this file used to state 10 %, which is also the
|
||||
number config.yaml's own `inverters:` example states, so `bms_floor=10.0`
|
||||
written at main.py's call site in place of `inv.bms_soc_floor` answered
|
||||
identically in every check here and in the other 22 files. A default that
|
||||
happens to agree with the fixture is not a pin.
|
||||
"""
|
||||
return [{"name": n, "setpoint_entity": f"number.sp_{t}",
|
||||
"soc_entity": f"sensor.soc_{t}", "batt_entity": f"sensor.batt_{t}",
|
||||
"max_w": 2000, "bms_soc_floor": _FLOOR_PCT}
|
||||
for n, t in (("inverter-a", "a"), ("inverter-b", "b"))]
|
||||
"max_w": 2000, "bms_soc_floor": f}
|
||||
for (n, t), f in zip((("inverter-a", "a"), ("inverter-b", "b")),
|
||||
floors)]
|
||||
|
||||
|
||||
def _ctrl(hass, store=None, **over):
|
||||
def _ctrl(hass, store=None, *, floors=(_FLOOR_PCT, _FLOOR_PCT), **over):
|
||||
"""A two-inverter Controller, with the NEIGHBOURING guards given long windows.
|
||||
|
||||
⚠️ THE LONG `circulation_hold_s` AND SIGN HOLDS ARE ISOLATION, NOT A CLAIM
|
||||
@@ -367,7 +385,7 @@ def _ctrl(hass, store=None, **over):
|
||||
below would be measuring the wrong thing.
|
||||
"""
|
||||
opts = {"meter_entity": "sensor.grid", "meter_source": "off",
|
||||
"inverters": _roster(), "gain": 0.6, "slew_w": 1000,
|
||||
"inverters": _roster(floors), "gain": 0.6, "slew_w": 1000,
|
||||
# ⚠️ 1 s, NOT THE SHIPPED 95. This window is WALL CLOCK - the
|
||||
# detector takes the caller's `now`, and `_drive()` runs fourteen
|
||||
# real cycles 0.2 s apart, so a shipped-length hold would make every
|
||||
@@ -521,6 +539,193 @@ check("a wedged unit BETWEEN its own cut-out and the site's peak_soc_floor is "
|
||||
and float(_cbf.o.get("peak_soc_floor")) == 20.0)
|
||||
|
||||
|
||||
# ===========================================================================
|
||||
print()
|
||||
print("=" * 72)
|
||||
print("4b. THE NUMBERS THIS CHECK READS ARE THE CONFIGURED ONES, AND THAT IS")
|
||||
print(" GRADED AT A CONFIG THAT IS NOT THE SHIPPED ONE")
|
||||
print("=" * 72)
|
||||
# ⚠️ WHY THIS PART EXISTS, AND IT IS NOT A MUTATION SCORE. Two of the values
|
||||
# main.py hands this check are OPTIONS, and the paragraph above
|
||||
# `delivery.MIN_W_IS_SATURATION_W` and the `delivery_hold_s` block in
|
||||
# config.yaml both make a PROMISE about them in shipped, operator-readable
|
||||
# prose: there is no fourth copy of a default to keep in step, and no way for
|
||||
# the two to drift, because an operator who raises `saturation_w` has told the
|
||||
# loop that a bigger gap is ordinary tracking and this check moves with them BY
|
||||
# CONSTRUCTION. A literal written at the call site breaks exactly that promise,
|
||||
# silently, and the promise is why the design was chosen over a `delivery_w`
|
||||
# key.
|
||||
#
|
||||
# ⚠️ AND EVERY FIXTURE ABOVE IS BLIND TO IT, WHICH IS THIS REPOSITORY'S
|
||||
# RECURRING DEFECT (MUTATION.md's third failure mode): a fixture whose values
|
||||
# cannot reach the failure it names. Part 4's gaps are all far above BOTH the
|
||||
# shipped `saturation_w` and any smaller literal, and every `bms_soc_floor` in
|
||||
# this file was 10 - the number config.yaml's own example states. So
|
||||
#
|
||||
# self.tuning.saturation_w -> 250.0 (-19 B)
|
||||
# bms_floor=inv.bms_soc_floor -> 10.0 (-13 B)
|
||||
#
|
||||
# were BOTH survivors of the whole 23-file suite, not of this file alone. The
|
||||
# two blocks below are what kills them, and they kill not just those two
|
||||
# literals but EVERY literal: each pair of arms is answered one way at one
|
||||
# configured value and the other way at another, on the same fixture, so no
|
||||
# single constant can satisfy both rows.
|
||||
|
||||
print()
|
||||
print(" (a) THE WATTS - `saturation_w`, raised to a value inside its own")
|
||||
print(" schema. Same load, same wedged unit, two configured thresholds.")
|
||||
|
||||
# 1800 is inside the shipped schema `int(100,2000)` and is not the shipped
|
||||
# default - both asserted below rather than asserted here in a comment. The
|
||||
# load is what puts B's shortfall BETWEEN the two: above the shipped threshold,
|
||||
# below the raised one. The gap itself is printed by the run that produces it
|
||||
# and is never written down here; what is asserted is the ORDERING.
|
||||
_SAT_RAISED = 1800
|
||||
_SAT_LOAD_W = 1600.0
|
||||
_SAT_SHIPPED = int(read_option("saturation_w"))
|
||||
_sat_lo, _sat_hi = (int(x) for x in re.match(
|
||||
r"int\((\d+),(\d+)\)", read_option("saturation_w", "schema")).groups())
|
||||
|
||||
|
||||
async def _at_saturation_w(sat):
|
||||
hass = _DeliveryHass(load_w=_SAT_LOAD_W)
|
||||
c = _ctrl(hass, saturation_w=sat)
|
||||
return c, await _drive(c, watch=_sample)
|
||||
|
||||
|
||||
_c_ship, _r_ship = asyncio.run(_at_saturation_w(_SAT_SHIPPED))
|
||||
_c_up, _r_up = asyncio.run(_at_saturation_w(_SAT_RAISED))
|
||||
_b_ship, _b_up = _c_ship.inverters[1], _c_up.inverters[1]
|
||||
_gap_ship = short_by(_b_ship.standing_w(), _b_ship.batt)
|
||||
_gap_up = short_by(_b_up.standing_w(), _b_up.batt)
|
||||
|
||||
check(f"the raised threshold is a config an operator can actually enter: "
|
||||
f"{_SAT_RAISED} W is inside the shipped schema "
|
||||
f"{read_option('saturation_w', 'schema')}, and it is NOT the shipped "
|
||||
f"default ({_SAT_SHIPPED} W) - both read out of config.yaml, not typed "
|
||||
f"here",
|
||||
_sat_lo <= _SAT_RAISED <= _sat_hi and _SAT_RAISED != _SAT_SHIPPED)
|
||||
check("...and the controller really is running on it - `Tuning.saturation_w` "
|
||||
"carries the option through, so this is a changed CONFIG and not a "
|
||||
"changed test",
|
||||
_c_up.tuning.saturation_w == float(_SAT_RAISED)
|
||||
and _c_ship.tuning.saturation_w == float(_SAT_SHIPPED))
|
||||
|
||||
# ⚠️ THE VACUOUS-PASS GUARD AGAIN, and here it is the whole load. "the raised
|
||||
# arm named nobody" reads identically against a fixture where B was never
|
||||
# asked, was not short, or was explained away. So the raised arm is asserted to
|
||||
# have reached the threshold comparison and to have been turned away by NOTHING
|
||||
# BUT the number.
|
||||
check("the raised arm REACHED the comparison: B was asked for a discharge "
|
||||
"share, is short of it, is live, is not parked, and NOTHING accounts for "
|
||||
"it - the only thing standing between this unit and an alarm is the "
|
||||
"configured watts",
|
||||
float(_b_up.standing_w()) > 0 and _gap_up is not None
|
||||
and not _b_up.sign_wd.tripped
|
||||
and account(live=True, parked=False, soc=_b_up.soc,
|
||||
bms_floor=_b_up.bms_soc_floor) is None)
|
||||
check("...and its shortfall lands STRICTLY BETWEEN the two configured "
|
||||
"thresholds, which is the one place the two answers can differ. Part 4's "
|
||||
"fixtures are all above both, which is exactly why they cannot see this",
|
||||
_gap_up is not None and float(_SAT_SHIPPED) < _gap_up < float(_SAT_RAISED))
|
||||
|
||||
check("AT THE SHIPPED THRESHOLD THE UNIT IS NAMED",
|
||||
_r_ship[-1]["named"] == ("inverter-b",))
|
||||
check("AT THE RAISED THRESHOLD, ON THE SAME FIXTURE, IT IS NOT - the operator "
|
||||
"has told the loop that a gap this size is ordinary tracking, and this "
|
||||
"check moved with them. THIS PAIR IS THE PIN: a literal at the call site "
|
||||
"is one number, and no one number answers both of these rows",
|
||||
_r_up[-1]["named"] == ())
|
||||
print(f" shipped saturation_w {_SAT_SHIPPED} W: B short by "
|
||||
f"{_gap_ship:.0f} W -> named {_r_ship[-1]['named']}")
|
||||
print(f" raised saturation_w {_SAT_RAISED} W: B short by "
|
||||
f"{_gap_up:.0f} W -> named {_r_up[-1]['named']}")
|
||||
|
||||
# And the same two answers out of the pure function, on the raised arm's OWN
|
||||
# two watt figures - so the flip is a property of `delinquent()`'s threshold
|
||||
# and not of anything the controller did differently between the two runs.
|
||||
_pair = [U("inverter-a", float(_c_up.inverters[0].standing_w()),
|
||||
_c_up.inverters[0].batt),
|
||||
U("inverter-b", float(_b_up.standing_w()), _b_up.batt)]
|
||||
check("...and `delinquent()` says the same thing about that one pair of watt "
|
||||
"figures: named at the shipped number, silent at the raised one. The "
|
||||
"threshold is the only input that moved",
|
||||
list(delinquent(_pair, _SAT_SHIPPED)) == ["inverter-b"]
|
||||
and delinquent(_pair, _SAT_RAISED) == {})
|
||||
|
||||
print()
|
||||
print(" (b) THE PERCENT - each unit's OWN `bms_soc_floor`, at two cut-outs")
|
||||
print(" that BRACKET the shipped example from both sides.")
|
||||
|
||||
# ⚠️ WHY TWO ARMS AND NOT ONE. A single arm at a deeper cut-out kills `10.0`
|
||||
# but not `50.0`; a single arm at a shallower one kills `10.0` but not `0.0`.
|
||||
# One arm on each side of the shipped example leaves no constant at all: the
|
||||
# deep arm must stay SILENT (its pack is genuinely below its own cut-out) and
|
||||
# the shallow arm must SPEAK (its pack is genuinely above its own cut-out), and
|
||||
# a literal that satisfies the first cannot satisfy the second.
|
||||
_FLOOR_DEEP, _DEEP_SOC = 25, 15.0 # pack BELOW its own cut-out: cold
|
||||
_FLOOR_SHALLOW, _SHAL_SOC = 5, 8.0 # pack ABOVE its own cut-out: wedged
|
||||
_floor_lo, _floor_hi = (int(x) for x in re.match(
|
||||
r"int\((\d+),(\d+)\)", read_option("bms_soc_floor", "schema")).groups())
|
||||
|
||||
|
||||
async def _at_floor(b_floor, b_soc, peak):
|
||||
hass = _DeliveryHass(b_soc=b_soc)
|
||||
# ⚠️ `peak_soc_floor` IS RAISED WITH THE DEEP ARM SO THE FIXTURE STAYS A
|
||||
# CONFIG THE ADD-ON WOULD START ON: validate.py rule 8 refuses a
|
||||
# `peak_soc_floor` at or below ANY unit's `bms_soc_floor`. A fixture that
|
||||
# only a refused config can produce would grade a state no install reaches.
|
||||
c = _ctrl(hass, floors=(_FLOOR_PCT, b_floor), peak_soc_floor=peak)
|
||||
return c, await _drive(c, watch=_sample)
|
||||
|
||||
|
||||
_c_deep, _r_deep = asyncio.run(_at_floor(_FLOOR_DEEP, _DEEP_SOC, 30))
|
||||
_c_shal, _r_shal = asyncio.run(_at_floor(_FLOOR_SHALLOW, _SHAL_SOC, 20))
|
||||
_bd, _bs = _c_deep.inverters[1], _c_shal.inverters[1]
|
||||
|
||||
check(f"both cut-outs are configs an operator can enter - inside the shipped "
|
||||
f"schema {read_option('bms_soc_floor', 'schema')} - and NEITHER is the "
|
||||
f"{read_option('bms_soc_floor')} % this file and config.yaml's own "
|
||||
f"example both state, which is the number a literal would have agreed "
|
||||
f"with everywhere",
|
||||
_floor_lo <= _FLOOR_SHALLOW < int(read_option("bms_soc_floor"))
|
||||
< _FLOOR_DEEP <= _floor_hi)
|
||||
check("...and each arm is a config validate.py rule 8 accepts: its "
|
||||
"peak_soc_floor is above EVERY unit's own cut-out",
|
||||
all(float(c.o.get("peak_soc_floor")) > float(i.bms_soc_floor)
|
||||
for c in (_c_deep, _c_shal) for i in c.inverters))
|
||||
check("...and the two arms are IDENTICAL IN THE POWER DOMAIN on every cycle - "
|
||||
"grid, site target, every share, every measured watt. The configured "
|
||||
"cut-out is the only thing that differs, which is part 4's claim made "
|
||||
"again at two cut-outs that are not the shipped one",
|
||||
_power_domain(_r_deep) == _power_domain(_r_shal))
|
||||
|
||||
check(f"a pack at {_DEEP_SOC:.0f} % against its OWN {_FLOOR_DEEP} % cut-out is "
|
||||
f"cold, and is NOT named - even though it is far above the "
|
||||
f"{read_option('bms_soc_floor')} % a literal would have graded it "
|
||||
f"against, which would have called an empty pack a fault",
|
||||
_r_deep[-1]["named"] == () and float(_bd.bms_soc_floor) == _FLOOR_DEEP
|
||||
and _bd.soc == _DEEP_SOC)
|
||||
check("...and it REACHED that decision: it was asked for a discharge share, "
|
||||
"was short of it by more than saturation_w, and was turned away by "
|
||||
"`account()` alone",
|
||||
float(_bd.standing_w()) > 0
|
||||
and short_by(_bd.standing_w(), _bd.batt) > _c_deep.tuning.saturation_w
|
||||
and account(live=True, parked=False, soc=_bd.soc,
|
||||
bms_floor=_bd.bms_soc_floor) is not None)
|
||||
check(f"a pack at {_SHAL_SOC:.0f} % against its OWN {_FLOOR_SHALLOW} % cut-out "
|
||||
f"is WEDGED, and IS named - even though it is below the "
|
||||
f"{read_option('bms_soc_floor')} % a literal would have explained it "
|
||||
f"away with, which would have lost the fault this card exists to find. "
|
||||
f"THIS ROW AND THE ONE ABOVE ARE THE PIN: no constant answers both",
|
||||
_r_shal[-1]["named"] == ("inverter-b",)
|
||||
and float(_bs.bms_soc_floor) == _FLOOR_SHALLOW and _bs.soc == _SHAL_SOC)
|
||||
print(f" deep cut-out {_FLOOR_DEEP} %, SoC {_DEEP_SOC:.0f} % -> named "
|
||||
f"{_r_deep[-1]['named']}")
|
||||
print(f" shallow cut-out {_FLOOR_SHALLOW} %, SoC {_SHAL_SOC:.0f} % -> "
|
||||
f"named {_r_shal[-1]['named']}")
|
||||
|
||||
|
||||
# ===========================================================================
|
||||
print()
|
||||
print("=" * 72)
|
||||
|
||||