SAFETY-42 round 2: pin the two thresholds at a config that is not the shipped one
checks / unit (pull_request) Successful in 6m7s
checks / unit (pull_request) Successful in 6m7s
THE BLOCKER. At the `delinquent()` call site, `self.tuning.saturation_w` -> `250.0` (-19 B) was a survivor of all 23 suites. It is not an equivalent mutant: two copies of inverter A, B wedged, `saturation_w: 1800` (inside its own schema int(100,2000)) and a load of 1600 W put B's shortfall strictly between the literal and the configured value - head names nobody, the mutant names B. At the shipped 500 both name it, which is exactly why every fixture in part 4 was blind: their gaps are all above both thresholds. It matters beyond a mutation score. `delivery.py`'s MIN_W_IS_SATURATION_W note and the `delivery_hold_s` block in config.yaml both promise an operator, in shipped prose, that there is no fourth copy of a threshold to keep in step and no way for the two to drift - raise `saturation_w` and this check moves with you. A literal at the call site removes exactly that promise, silently, and the promise is why the design was chosen over a `delivery_w` key. ASKING THE SAME QUESTION OF EVERY OTHER NUMBER THIS CHECK READS FOUND A SECOND SURVIVOR OF ALL 23 SUITES: `bms_floor=inv.bms_soc_floor` -> `10.0` (-13 B), invisible because config.yaml's own example states 10 % and every fixture in this file used it. Two arms bracket it: a pack at 15 % against its own 25 % cut-out is cold and must stay unnamed (the literal names an empty pack), and a pack at 8 % against its own 5 % cut-out is wedged and must be named (the literal explains the fault away). One arm on each side leaves no constant at all. `delivery_hold_s` and `is_live()`'s window were ALREADY pinned - the fixtures had to move them to run - and `LINK_STALE_S` has no option behind it, so "pinned across a changed config" is not available for it and is not claimed. DECISIONS section 9 enumerates all of it with the deltas and which check kills which. Verified in the CI image, tree mounted :ro, `python3 -B`, `__pycache__` purged and counted before every run (TEST-15): R5 saturation_w -> 250.0 -19 B killed by part 4b(a) R6 bms_soc_floor -> 10.0 -13 B killed by part 4b(b), both arms R7 arm(self.delivery_cfg) -> DeliveryConfig() -1 B killed (already) R8 is_live(now) -> is_live(now, 3600.0) +8 B killed (already) R9 pack cut-out -> conjoined site floor +105 B killed twice head: 23/23 test files PASS, no bytecode written during the run. No shipped behaviour changes: the only edits to app/ are comments. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
@@ -149,6 +149,22 @@ that direction would fire on every maintenance charge.
|
||||
two-inverter runs plus 1890 at one inverter as the control), the
|
||||
inverter-B sensitivity sweep the margin is sized on, and the mutation ledger.
|
||||
|
||||
⚠️ **AND THE TWO THRESHOLDS IT READS ARE NOW GRADED AT A CONFIG THAT IS NOT THE
|
||||
SHIPPED ONE.** `saturation_w` and each unit's `bms_soc_floor` are handed to this
|
||||
check from the running config, and the promise that comes with that - raise
|
||||
`saturation_w` and this check moves with you, there is no fourth copy of a
|
||||
default to keep in step - is only true while the call site passes the
|
||||
**configured** value. A literal equal to the shipped value keeps every fixture
|
||||
green and removes the promise silently, and two such literals were survivors of
|
||||
all 23 suites - measured, not argued - because no fixture that reaches this
|
||||
check had ever run at a `saturation_w` other than the shipped 500 or at a
|
||||
`bms_soc_floor` other than the shipped example's 10. Part 4b of
|
||||
`test_delivery.py` now runs the same fault at a raised `saturation_w` and at two
|
||||
cut-outs that bracket 10 from both sides, and each pair must answer two
|
||||
different ways - so no constant passes. §9 of the decision record enumerates
|
||||
every number this check reads and says which were already pinned this way and
|
||||
which were not.
|
||||
|
||||
⚠️ **A PER-INVERTER POWER READING THAT HAS STOPPED FOLLOWING ITS OWN COMMAND IS
|
||||
NOW `None`, NOT A HELD NUMBER ([[SAFETY-37]]).** `Inverter.batt` (register
|
||||
`0x0518`) goes through a freshness gate: unchanged for >= 35 s *while* the
|
||||
|
||||