MAINT-28 fix-forward round 4: the paused pack's cap is its own part of the guard's floor, the largest of the period, per unit
Owner 2026-11-13 ("ok max", relayed by the manager): while the pause holds,
the pack in maintenance CHARGE gives at most the largest floor the guard
claimed in the quarter. The cap is now that pack's own part of the floor
(the floor less what the other units are placed at, split without the cap),
the largest in the 15-minute period, kept per unit (`_m28_hi`). 0 W while
the guard holds it at its reserve. test_maint28b: SoC check stated against
the owner-accepted give (0.70 point, measured 0.64); both-packs-able tests
(B on Cheap hours, B on Solar first); per-unit state and the one-slot
arbitrate. test_maint28 unchanged (5925 W). Pins: test_safety84
n2_charge_banked, test_packshare's one-resolve AST pin (a second call with
the same weights).
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
fb4a449591
commit
07d23d2eed
@@ -506,8 +506,8 @@ class Controller(InputsMixin, WritesMixin, TradeMixin, CycleMixin, AlarmsMixin,
|
||||
self._peak_needed = False
|
||||
self._maint_shape_suspended = False
|
||||
self._maint_peak_hold = False # MAINT-28
|
||||
self._m28_q, self._m28_hi = None, 0.0 # MAINT-28: period, its most guard claim
|
||||
self._m28_step = {} # MAINT-28: unit -> (command, step at)
|
||||
self._m28_hi = {} # MAINT-28: unit -> (period, cap)
|
||||
# OPT-11: battery modes, off by default (SAFETY-10 section 1). Each
|
||||
# battery's mode and on/off switch live in the store, not in options,
|
||||
# so a change applies at once (`pack_use`, `pack_mode`).
|
||||
|
||||