MAINT-28 fix-forward round 4: the paused pack's cap is its own part of the guard's floor, the largest of the period, per unit
Owner 2026-11-13 ("ok max", relayed by the manager): while the pause holds,
the pack in maintenance CHARGE gives at most the largest floor the guard
claimed in the quarter. The cap is now that pack's own part of the floor
(the floor less what the other units are placed at, split without the cap),
the largest in the 15-minute period, kept per unit (`_m28_hi`). 0 W while
the guard holds it at its reserve. test_maint28b: SoC check stated against
the owner-accepted give (0.70 point, measured 0.64); both-packs-able tests
(B on Cheap hours, B on Solar first); per-unit state and the one-slot
arbitrate. test_maint28 unchanged (5925 W). Pins: test_safety84
n2_charge_banked, test_packshare's one-resolve AST pin (a second call with
the same weights).
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
fb4a449591
commit
07d23d2eed
@@ -38,8 +38,16 @@ MAINT-24's rate and its tests, N=1, the drain, modes off (digests of 1b5f7c9). T
|
||||
## Fix-forward (rig FAIL F-1, F-2; `reports/MAINT-28-test-report.md`)
|
||||
The sim had no battery-reading lag, and the first version said the 300 W line is far larger than the lag moves the estimate. That was wrong. The rig publishes a battery's power every 10 s; the meter is newer. After each guard step charge -> give (+500-1000 W) the next meter reading shows the give and the battery reading still shows the charge, so `grid + site_batt_w` drops by the step, under the 5650 W line: 69/69, 132/133, 215/215, 51/51 releases at a median 5430 W with the house at 6450 W or more. Test: `test_maint28b.py`, sim `Lag.batt_period_s`.
|
||||
|
||||
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 13 s after the load (7 s in the test), not 0: the first settled estimate. No cut-back is touched.
|
||||
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 4 s after the load (12 s in test_maint28b), not 0: the first settled estimate. No cut-back is touched.
|
||||
|
||||
**F-2 and the cap (owner 2026-11-13): while the pause holds, the maintenance pack gives at most what the guard claimed this period.** While the pause holds (N>=2, month aim above the cap), the pack in maintenance CHARGE gets a unit limit `hi` = the largest floor of the guard's claim in this 15-minute period (reset at each period and when the pause ends), at any SoC; 0 W when the guard places its claim on the other packs, i.e. this pack is under its reserve (`peak_guard.held`; the claim itself is site-scoped). Other packs are unchanged (B not in maintenance still gives for the house). Why not `hi` = 0 W: it crosses the guard's claim and resolves to 0 W (house 12 kW, B under its reserve: quarter 6713 W, a new month peak). Why the largest, not the present floor: the guard alone lands 10 W over its aim (SAFETY-126) because its floor drops to 0 W each time the projection reaches the aim, and the pack steps on and off (15 give/idle switches in 45 min, test_maint28 quarter 5960.1 W against 5950 W); holding the largest floor of the period gives test_maint28 5925 W and 0 switches. Sim, 45 min, house 6500 W: A at 49 %: A gives 0.37 kWh (uncapped 2.39), SoC 50.5 -> 48.3 %, charge/give flips 1, give/idle switches 0, quarters 1422 1370 2550 W (all under the aim), charge back 4 s after the load. B at 18.2 % in CHARGE: f3f9483 gave 1.89 kWh to 10.0 % (log "giving nothing for the peak"); now 0.00 kWh, 18.2 %, quarters 5948 and 5952 W: the guard places everything on the other pack, and its own landing error shows (up to +9.5 W, inside SAFETY-126's 10 W; test_maint28b allows that and nothing more). test_safety84 n2_charge_banked: banked quarters 3349 and 3016 W against the aim 3950 W.
|
||||
**F-2 and the cap.** Owner 2026-11-13 ("1" = cap): while the pause holds, the pack in maintenance CHARGE gives only what the guard claims for the peak, at any SoC; other packs unchanged. Owner 2026-11-13 ("ok max", relayed by the manager): accepted "while the hold is on, the pack in maintenance CHARGE gives at most the largest floor the peak guard claimed in the current quarter" (about 0.37 kWh per 45-min peak in the sim; quarters at or under the aim).
|
||||
|
||||
Mutants, each red in `test_maint28b.py`: the freshness check dropped (always settled); the cap dropped.
|
||||
The rule as built (`Controller._m28_share()`): while the pause holds (N>=2, month aim above the cap) the pack gets a unit limit `hi` = the largest part of the guard's floor placed on it in this 15-minute period. Its part in a cycle is the floor less what the other units are placed at in this cycle's split without that limit, so a part the guard's split puts on the other pack is not this pack's. A pack the guard holds at its reserve (`peak_guard.held`) gets 0 W and its part starts again from 0 W. The largest part is kept per unit (`_m28_hi`, keyed by the unit) and dropped in a new period or when the pause ends; only one pack can be in maintenance CHARGE anyway (`maintenance.arbitrate()`, one slot per site).
|
||||
|
||||
Why the largest of the period and not the present part: the guard alone lands the quarter 9.5-10 W over its aim in the sim (SAFETY-126: its own projection ends on 5950.0 W but the meter reading it counts lags the true grid), and with the present part only, test_maint28 part 1 ends at 5960.1 W; the largest of the period lets the loop keep A up and it ends at 5925 W. Why not `hi` = 0 W: with the other pack under its reserve the guard needs this one (test_maint28b, house 12 kW, B at 18 %: A gives 1.07 kWh for the guard).
|
||||
|
||||
Tests (test_maint28b, 13-min load, A 5 kW): A at 49 %: SoC drop 0.64 point (the owner's 0.37 kWh per 45 min is 0.70 point here; the check is <= 0.70). Both packs able, B on Cheap hours: B is placed nothing, A's limit is the period's largest floor (3087 W) and A gives 3081 W. B on Solar first (gives for the house): A's limit 3294 W against a period's largest floor of 6284 W, under it by 500 W or more in 564 of 569 paused cycles; A still gives 3294 W, so the quarter ends 3843 W, far under the aim: that is the cost of the largest-of-period rule when the other pack gives for the house.
|
||||
|
||||
Sim, rig shape, 45 min, house 6500 W: A in CHARGE at 49 %: A gives 0.17 kWh (f3f9483 0.44), SoC 50.5 -> 49.0 %, charge/give flips 1, give/idle switches 3, quarters 5358 1663 1899 2572 4476 W, charge back 4 s after the load; B (Cheap hours, not in maintenance) gives 3.04 kWh for the house (f3f9483 0.32). B at 18.2 % in CHARGE: f3f9483 gave 1.89 kWh to 10.0 %; now 0.00 kWh, 18.2 %, quarters 5948 and 5952 W (the guard alone, on A). test_safety84 n2_charge_banked: banked quarters 3349 and 3217 W against the aim 3950 W.
|
||||
|
||||
Mutants, each red: the freshness check dropped (always settled); the cap dropped; the other units' placement dropped (part = the whole floor); one cap for the site instead of per unit; the 0 W for a held pack dropped (all in `test_maint28b.py`); the period's largest dropped (present part only: `test_maint28.py` part 1 quarter 5960 W).
|
||||
|
||||