SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) * LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both units 10-16 times an hour after load steps (site held 0 W). 2 s and slower ticks are unchanged. - REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that stops taking charge is always above its cut-out level. - test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal; the release/1.0 checks are restored and a span check added. - test_refusal_units: lagged-reading and full-battery plants, two new checks, U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
1a9c7523c9
commit
06aa09e28c
@@ -319,12 +319,14 @@ class Inverter:
|
||||
|
||||
# SAFETY-73. The direction this unit's battery refuses (+1 give, -1
|
||||
# take, 0 none), when that refusal or its last probe started, the
|
||||
# current probe's start, and the cycles of evidence so far. Memory
|
||||
# only, like SAFETY-52's: stop and start end it. Used at N>1 only.
|
||||
# current probe's start, and the cycles of evidence so far and when
|
||||
# they began. Memory only, like SAFETY-52's: stop and start end it.
|
||||
# Used at N>1 only.
|
||||
self.refused = 0
|
||||
self.refused_at = None
|
||||
self.probe_from = None
|
||||
self.ref_count = 0
|
||||
self.ref_since = None
|
||||
self.ref_sign = 0
|
||||
|
||||
# -- store ---------------------------------------------------------------
|
||||
|
||||
Reference in New Issue