Merge release/1.0 (e3e4ba6) into opt15-price-run-fixes
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
clears the chargers, a probing refuser included, while a battery drains
(SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
(`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.
Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
until the quarter's first sample, as the old edge tick was not, so a
standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
drain and the day plan against the probe.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -344,6 +344,21 @@ class _Narrowed:
|
||||
self.lo, self.hi = lo, hi
|
||||
|
||||
|
||||
def pin_w(b):
|
||||
"""The watts a unit's own SET places once held inside its hard limits,
|
||||
as `plan()` places a standing pin, or None when the unit has no SET."""
|
||||
pv = getattr(b, "pinned_w", None)
|
||||
if getattr(b, "gate", None) is None or pv is None:
|
||||
return None
|
||||
lo, hi = _int_envelope(b)
|
||||
return float(pv) if lo > hi else float(_clamp_int(round(float(pv)), lo, hi))
|
||||
|
||||
|
||||
def hi_w(b):
|
||||
"""A unit's upper hard limit as `plan()` narrows it to whole W (SAFETY-84)."""
|
||||
return float(_int_envelope(b)[1])
|
||||
|
||||
|
||||
def loop_bound(bounds, live=None):
|
||||
"""OPT-11. `(lo, hi)`: what the units can place when the LOOP decides.
|
||||
|
||||
@@ -364,11 +379,8 @@ def loop_bound(bounds, live=None):
|
||||
continue
|
||||
if getattr(b, "contradiction", False):
|
||||
continue
|
||||
pv = getattr(b, "pinned_w", None)
|
||||
if getattr(b, "gate", None) is not None and pv is not None:
|
||||
lo, hi = _int_envelope(b)
|
||||
p = float(pv) if lo > hi else float(_clamp_int(round(float(pv)),
|
||||
lo, hi))
|
||||
p = pin_w(b)
|
||||
if p is not None:
|
||||
lo_sum += min(0.0, p)
|
||||
hi_sum += max(0.0, p)
|
||||
continue
|
||||
|
||||
@@ -76,6 +76,12 @@ from . import allocator
|
||||
P_SAFETY = 100 # stopped, inputs missing, shutting down, device limits
|
||||
P_MAINTENANCE = 60 # maintenance owns the actuator outright (drain, hold)
|
||||
P_PEAK = 50 # capacity-tariff peak shaving - costs real money
|
||||
# The order in effect: safety limits and the SAFETY-73 refusal > the peak
|
||||
# guard > maintenance > modes > trade > loop. A peak floor above a drain still
|
||||
# binds: the `drain` site floor at N>=2 (SAFETY-78), refiled at P_MAINTENANCE
|
||||
# at N=1 (SAFETY-83); over a HOLD, `_peak_over_hold()` (SAFETY-86).
|
||||
# A cheap-window charge is suspended while the peak guard holds and, at N>=2,
|
||||
# sized to the quarter's headroom (SAFETY-84).
|
||||
P_MAINT_SHAPE = 40 # maintenance shaping the loop (charge-only)
|
||||
# OPT-04. §10.1 priority 3 - price arbitrage. ⚠️ ITS POSITION IS THE SPEC, NOT A
|
||||
# preference: P_PEAK (50) is ABOVE it so clause 2 lets the capacity-tariff floor
|
||||
@@ -184,6 +190,22 @@ CLAIM_SCOPE = {
|
||||
# the banner and the claim an install has had since SAFETY-02 shipped.
|
||||
# `Controller.cycle()` does not even arm the site detector there.
|
||||
"sign_site": SCOPE_SITE,
|
||||
# main.py: `Claim.limit("drain", P_MAINTENANCE, lo=...)`, SAFETY-78. At
|
||||
# N>=2, while a pack's maintenance drain is pinned, the site target may
|
||||
# not go below what that pin places: below it a sibling would have to
|
||||
# charge against the drain (circulation, refused, 0 W). A site `lo`,
|
||||
# never filed at N=1. DECISIONS/SAFETY-78-drain-at-two.md.
|
||||
"drain": SCOPE_SITE,
|
||||
# main.py: `Claim.limit("charge", P_MAINT_SHAPE, hi=...)`, SAFETY-84. The
|
||||
# mirror of `drain` for a cheap-window maintenance charge at N>=2: the site
|
||||
# target may not go above what the charging pack's own `hi` asks, or a
|
||||
# sibling would have to give against it. Never filed at N=1.
|
||||
# DECISIONS/SAFETY-84-charge-at-two.md.
|
||||
"charge": SCOPE_SITE,
|
||||
# main.py: `Claim.limit("hold", P_MAINTENANCE, hi=...)`, SAFETY-86. While a
|
||||
# holding pack gives the peak shortfall at N>=2, the site target stays at
|
||||
# the peak floor, what the pin and the others place. Never filed at N=1.
|
||||
"hold": SCOPE_SITE,
|
||||
|
||||
# --- UNIT: about one pack, one inverter, one device -------------------
|
||||
# main.py: `Claim.limit("device", P_SAFETY, self.dev_min, self.dev_max,
|
||||
@@ -613,7 +635,7 @@ def site_resolve(claims: list) -> Resolution:
|
||||
|
||||
|
||||
def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
tick=None) -> Resolution:
|
||||
tick=None, reserve=()) -> Resolution:
|
||||
"""The three stages, in order, over one cycle's claims.
|
||||
|
||||
`units` is the site's roster of inverters. Left None it is derived from the
|
||||
@@ -715,6 +737,13 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
gate, held = _unit_modes(out, site_claims, bounds, live)
|
||||
if callable(weights):
|
||||
weights = weights(out.target_w)
|
||||
# SAFETY-87/91: units under their peak reserve weigh 0 while the site
|
||||
# gives, so the others carry the target first. An Off battery gives the
|
||||
# peak's shortfall, so it goes before them when no other unit is left.
|
||||
reserve = set(reserve) if out.target_w > 0.0 else set()
|
||||
if held and reserve and not set(bounds) - held - reserve:
|
||||
held = set()
|
||||
held = held | reserve
|
||||
if held:
|
||||
weights = {u: (0.0 if u in held else
|
||||
(1.0 if weights is None else weights.get(u, 1.0)))
|
||||
|
||||
@@ -260,6 +260,22 @@ def loop_clamp_note(d) -> str:
|
||||
return ""
|
||||
|
||||
|
||||
def shortfall_note(named) -> str:
|
||||
"""SAFETY-85: the alarm text while another owner sets the batteries.
|
||||
`named` is `[(inverter name or None, asked W, given W)]`, one per battery
|
||||
that gave less than asked."""
|
||||
return f"{REASON_CODE}: " + ", ".join(
|
||||
f"{name or 'the battery'} gives {given:+.0f} W of the {asked:+.0f} W "
|
||||
f"asked" for name, asked, given in named)
|
||||
|
||||
|
||||
def delivery_short(asked_w, given_w, margin_w) -> bool:
|
||||
"""SAFETY-85: did a battery asked to discharge give more than `margin_w`
|
||||
less? A charge is never short: a full pack tapers (SAFETY-42 section 7)."""
|
||||
asked, given = float(asked_w), float(given_w)
|
||||
return asked > 0.0 and asked - given > abs(float(margin_w))
|
||||
|
||||
|
||||
def write_clamp_note(named) -> str:
|
||||
"""The write-side alarm text: `named` is `[(inverter name or None,
|
||||
ClampResult)]` for every inverter whose write was cut back this cycle.
|
||||
@@ -382,6 +398,10 @@ class ClampWatchdog:
|
||||
self.over_rating = 0 # bug=True: "Power request too high"
|
||||
self.bound = 0 # bug=False: "Battery is not keeping up"
|
||||
self.episodes = 0 # rising edges
|
||||
# SAFETY-85: episodes with a bug=False engagement. The status row
|
||||
# counts these; counting cycles read 861 on one rig run.
|
||||
self.bound_episodes = 0
|
||||
self._bound_counted = False
|
||||
self.since: datetime | None = None
|
||||
self.last_alarm: datetime | None = None
|
||||
self.reason = ""
|
||||
@@ -436,6 +456,10 @@ class ClampWatchdog:
|
||||
self.spoken = False
|
||||
self.bug = False
|
||||
self.bug_spoken = False
|
||||
self._bound_counted = False
|
||||
if not bug and not self._bound_counted:
|
||||
self._bound_counted = True
|
||||
self.bound_episodes += 1
|
||||
if bug or not self.bug:
|
||||
self.reason = reason
|
||||
self.facts = tuple(facts)
|
||||
|
||||
@@ -382,6 +382,9 @@ class Decision:
|
||||
# SAFETY-52. The refused direction to carry back in (+1 discharge, -1
|
||||
# charge, 0 none), or None when the caller does not carry it.
|
||||
refused: int | None = None
|
||||
# SAFETY-85. The `bound` held the integrator or the command this cycle,
|
||||
# so the batteries' limits, not the loop, decided it.
|
||||
held: bool = False
|
||||
|
||||
|
||||
def slew_limit_w(tuning: Tuning) -> float:
|
||||
@@ -481,6 +484,8 @@ def compute(
|
||||
refused: int | None = None,
|
||||
probe: bool = False,
|
||||
bound: tuple | None = None,
|
||||
gave_nothing: bool | None = None,
|
||||
idle_w: float = 0.0,
|
||||
) -> Decision:
|
||||
"""One control cycle. A cycle is one meter update (~5 s on a HomeWizard P1).
|
||||
|
||||
@@ -494,6 +499,13 @@ def compute(
|
||||
`bound` OPT-11: `(lo, hi)`, what the batteries may place this tick with
|
||||
their modes applied (`allocator.loop_bound()`), or None. See
|
||||
MODE_BOUND below. None is the law as it was.
|
||||
`gave_nothing` SAFETY-94: the caller's span check - the reading stayed
|
||||
under REFUSED_BELOW_W, one way, for SETTLE_CYCLES spanning
|
||||
REFUSED_SPAN_S. A refusal engages only with it. None leaves it
|
||||
out (compute() alone, as before).
|
||||
`idle_w` SAFETY-97: what `actual_w` reads while the batteries give
|
||||
nothing (app/idle.py). The refusal's band and its end are
|
||||
centred on it. 0 is the law as it was.
|
||||
"""
|
||||
reason = "tracking"
|
||||
# OPT-11: a bound that leaves out 0 W would FORCE a direction, which no
|
||||
@@ -614,11 +626,13 @@ def compute(
|
||||
# OPT-11: the integrator does not wind past what the modes let the
|
||||
# batteries place. Only a side tighter than the rail is left in `bound`
|
||||
# (above), so this never takes SAFETY-03's `i_clamped` away from the rail.
|
||||
held_by_bound = False
|
||||
if bound is not None:
|
||||
held = max(float(bound[0]), min(float(bound[1]), i_w))
|
||||
if held != i_w:
|
||||
i_w = held
|
||||
reason = MODE_BOUND
|
||||
held_by_bound = True
|
||||
|
||||
# ⚠️ Applied EVERY cycle, frozen or not: the freeze is conditional, this
|
||||
# bound is not. It is what makes the worst-case unwind time finite and
|
||||
@@ -812,13 +826,18 @@ def compute(
|
||||
# `saturation_w` is a refusal, not a slow plant. The drop to 0 skips the slew
|
||||
# limit because it only removes an ask the battery is not meeting.
|
||||
if refused is not None:
|
||||
# SAFETY-94: and only when the reading has given nothing for the
|
||||
# whole span, not just now. `sat_count` also counts the cycles a
|
||||
# healthy battery spends reversing through its lag (-2000 W towards
|
||||
# +800 W): at a 1 s meter its 12 cycles end as the reading passes 0.
|
||||
if (refused == 0 and frozen and sat_count >= SETTLE_CYCLES
|
||||
and abs(prev_w) > tuning.saturation_w
|
||||
and abs(actual_w) < REFUSED_BELOW_W):
|
||||
and abs(actual_w - idle_w) < REFUSED_BELOW_W
|
||||
and gave_nothing is not False):
|
||||
refused = 1 if prev_w > 0 else -1
|
||||
if refused and refused * i_w < 0:
|
||||
refused = 0 # the loop wants the other way
|
||||
elif refused and refused * actual_w >= PROBE_ANSWER_W:
|
||||
elif refused and refused * (actual_w - idle_w) >= PROBE_ANSWER_W:
|
||||
refused = 0 # it delivers: a probe answered,
|
||||
# or a slow reading arriving
|
||||
elif refused:
|
||||
@@ -839,6 +858,7 @@ def compute(
|
||||
if inside != target:
|
||||
target = inside
|
||||
reason = MODE_BOUND
|
||||
held_by_bound = True
|
||||
# SAFETY-48's lead cap above may pull the integrator back toward the
|
||||
# slewed command; what is CARRIED stays inside the bound too.
|
||||
i_w = max(float(bound[0]), min(float(bound[1]), i_w))
|
||||
@@ -860,7 +880,7 @@ def compute(
|
||||
|
||||
return Decision(float(target), sat_count, frozen, reason, float(i_w),
|
||||
i_clamped, clamped, float(i_bound_w), float(want),
|
||||
float(clamped_w), refused)
|
||||
float(clamped_w), refused, held_by_bound)
|
||||
|
||||
|
||||
def maintenance_charge_floor(
|
||||
|
||||
@@ -0,0 +1,262 @@
|
||||
"""OPT-11 P4: the day plan. Will the sun fill each battery before the
|
||||
expensive hours? If not, how much should it take from the grid?
|
||||
|
||||
Pure: the forecast (`solarfc`), the house profile, the price runs and the
|
||||
batteries in; a level per battery (`Plan.targets`) out. `modetrade.charge_to()`
|
||||
turns the level into permission to charge from the grid; main.py rebuilds the
|
||||
plan with the price runs (at most every 15 minutes) and keeps a level unless
|
||||
it moves by `HYST_KWH` or `HYST_FRAC` (`hold()`).
|
||||
|
||||
The sums (OPT-11-design section 1, "Excess solar", with the owner's answers):
|
||||
* `sun`: trust x the solar the house will not use, between now and the
|
||||
expensive run the cheap run is for, x the charge efficiency:
|
||||
`trust x sum_h max(0, forecast_h - house_h) x EFF`.
|
||||
* Solar first batteries take it first, up to the ceiling. What is left is
|
||||
shared by the Leftover solar batteries by their room.
|
||||
* Cheap hours only ignores the plan and fills to the ceiling, as in P3 and
|
||||
the design (section 1). Skipping the sun's share cost money in the replay
|
||||
(PR #156 review: 29.72 against 29.41 EUR on real 2026 prices).
|
||||
* A Leftover solar battery charges only up to what the house will draw from
|
||||
it in the expensive runs before the next cheap run, less its share:
|
||||
`min(ceiling, floor + house use / EFF) - share`. So it buys only the
|
||||
shortfall, not up to the ceiling.
|
||||
* Solar first never charges from the grid (owner, 2026-09-29).
|
||||
|
||||
The house profile is the add-on's own measurement, grid + battery power, per
|
||||
local hour, over the last `PROFILE_DAYS` days; the estimate for an hour is the
|
||||
median of that hour. It is net of the solar the house used itself, so for
|
||||
the solar sum it is never taken below the night-time median (`base()`).
|
||||
The site's own solar readings are not used: TEL-11 keeps them out of every
|
||||
control decision.
|
||||
"""
|
||||
|
||||
import statistics
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from .packmode import LEFTOVER_SOLAR, SOLAR_FIRST
|
||||
from .tariff import BILLING_TZ
|
||||
|
||||
EFF = 0.95 # charge (and discharge) efficiency
|
||||
HYST_KWH = 1.0 # a kept level moves only by this much...
|
||||
HYST_FRAC = 0.10 # ...or this share of the battery's shortfall
|
||||
PROFILE_DAYS = 7
|
||||
MIN_HOURS = 20 # hours of a day recorded before it counts
|
||||
NIGHT_HOURS = (0, 1, 2, 3, 4, 5, 22, 23)
|
||||
DEFAULT_TRUST_PCT = 70
|
||||
|
||||
# Site verdicts (the page's forecast line).
|
||||
SUNNY, PARTLY, DARK = "sunny", "partly", "dark"
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# The house profile
|
||||
# --------------------------------------------------------------------------- #
|
||||
def _local(t: datetime):
|
||||
return t.astimezone(BILLING_TZ)
|
||||
|
||||
|
||||
class HouseProfile:
|
||||
"""Hourly means of the house's net use (grid + battery power), kept per
|
||||
local day and hour: `{"YYYY-MM-DD": {hour: [mean_w, samples]}}`. The
|
||||
store holds `dump()`; `load()` takes it back and drops what is bad."""
|
||||
|
||||
def __init__(self, data=None):
|
||||
self.days = {}
|
||||
self._cur = None # (day, hour, sum, n)
|
||||
if isinstance(data, dict):
|
||||
self.load(data)
|
||||
|
||||
def load(self, data):
|
||||
for day, hours in data.items():
|
||||
try:
|
||||
datetime.strptime(str(day), "%Y-%m-%d")
|
||||
except ValueError:
|
||||
continue
|
||||
if not isinstance(hours, dict):
|
||||
continue
|
||||
row = {}
|
||||
for h, v in hours.items():
|
||||
try:
|
||||
hi, w = int(h), float(v)
|
||||
except (TypeError, ValueError):
|
||||
continue
|
||||
if 0 <= hi < 24 and abs(w) < 1e6:
|
||||
row[hi] = w
|
||||
if row:
|
||||
self.days[str(day)] = row
|
||||
|
||||
def dump(self) -> dict:
|
||||
return {d: {str(h): round(w, 1) for h, w in sorted(r.items())}
|
||||
for d, r in sorted(self.days.items())}
|
||||
|
||||
def add(self, now: datetime, house_w) -> bool:
|
||||
"""One reading. Returns True when an hour closed (then store it)."""
|
||||
lt = _local(now)
|
||||
key = (lt.strftime("%Y-%m-%d"), lt.hour)
|
||||
closed = False
|
||||
if self._cur is not None and self._cur[:2] != key:
|
||||
day, hour, s, n = self._cur
|
||||
if n >= 60: # about 5 minutes of readings
|
||||
self.days.setdefault(day, {})[hour] = s / n
|
||||
closed = True
|
||||
self._cur = None
|
||||
self._prune(lt)
|
||||
if house_w is None:
|
||||
return closed
|
||||
if self._cur is None:
|
||||
self._cur = (key[0], key[1], 0.0, 0)
|
||||
d, h, s, n = self._cur
|
||||
self._cur = (d, h, s + float(house_w), n + 1)
|
||||
return closed
|
||||
|
||||
def _prune(self, lt):
|
||||
"""Keep the last `PROFILE_DAYS` days; a day after today (the clock
|
||||
was wrong once) would never age out, so it goes too."""
|
||||
keep = (lt.date() - timedelta(days=PROFILE_DAYS)).isoformat()
|
||||
today = lt.date().isoformat()
|
||||
for d in [d for d in self.days if d < keep or d > today]:
|
||||
del self.days[d]
|
||||
|
||||
def ready(self) -> bool:
|
||||
"""At least one day with `MIN_HOURS` hours recorded."""
|
||||
return any(len(r) >= MIN_HOURS for r in self.days.values())
|
||||
|
||||
def hour_w(self, hour: int):
|
||||
vals = [r[hour] for r in self.days.values() if hour in r]
|
||||
return statistics.median(vals) if vals else None
|
||||
|
||||
def base(self):
|
||||
vals = [w for h in NIGHT_HOURS if (w := self.hour_w(h)) is not None]
|
||||
return statistics.median(vals) if vals else None
|
||||
|
||||
def estimator(self):
|
||||
"""`f(hour) -> W`, or None when not ready. Fixed at call time."""
|
||||
if not self.ready():
|
||||
return None
|
||||
base = self.base() or 0.0
|
||||
table = {}
|
||||
for h in range(24):
|
||||
w = self.hour_w(h)
|
||||
table[h] = base if w is None else w
|
||||
return lambda h: table[h], max(0.0, base)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# The plan
|
||||
# --------------------------------------------------------------------------- #
|
||||
@dataclass(frozen=True)
|
||||
class Plan:
|
||||
verdict: str # SUNNY / PARTLY / DARK
|
||||
sun_kwh: float # solar the batteries can count on
|
||||
fc_kwh: float # the forecast over the same span
|
||||
until: datetime # the expensive run the plan is for
|
||||
targets: dict # name -> level % (Leftover solar only)
|
||||
need_kwh: dict # name -> kWh from the grid (0: none)
|
||||
share_kwh: dict # name -> kWh of solar counted for it
|
||||
|
||||
|
||||
def _hour_slices(t0, t1):
|
||||
"""Local-hour slices of [t0, t1): (start, end, local hour)."""
|
||||
out, t = [], t0
|
||||
while t < t1:
|
||||
lt = _local(t)
|
||||
nxt = (lt.replace(minute=0, second=0, microsecond=0)
|
||||
+ timedelta(hours=1)).astimezone(timezone.utc)
|
||||
e = min(nxt, t1)
|
||||
out.append((t, e, lt.hour))
|
||||
t = e
|
||||
return out
|
||||
|
||||
|
||||
def _room(p, to_pct):
|
||||
if p.capacity_kwh is None or p.soc is None:
|
||||
return 0.0
|
||||
return max(0.0, float(to_pct) - float(p.soc)) / 100.0 * float(
|
||||
p.capacity_kwh)
|
||||
|
||||
|
||||
def plan(forecast, house, runs, now, packs, *, trust_pct, floor_pct,
|
||||
ceiling_pct):
|
||||
"""The day plan, or None when there is none to make: no forecast, no
|
||||
house profile yet, no price plan, or no expensive run after the cheap
|
||||
run. `house` is `HouseProfile.estimator()`'s answer. `packs` are
|
||||
`modetrade.Pack`s."""
|
||||
if forecast is None or house is None or runs is None or not runs.on \
|
||||
or runs.cheap is None:
|
||||
return None
|
||||
house_w, base_w = house
|
||||
until = next((g for g in runs.give if g.start >= runs.cheap.end), None)
|
||||
if until is None:
|
||||
return None
|
||||
trust = max(0.0, min(1.0, float(trust_pct) / 100.0))
|
||||
sun = fc_sum = 0.0
|
||||
for s, e, h in _hour_slices(now, until.start):
|
||||
pv = forecast.between(s, e)
|
||||
if pv is None:
|
||||
return None # the span reaches a day with no forecast
|
||||
hrs = (e - s).total_seconds() / 3600.0
|
||||
use = max(house_w(h), base_w) * hrs / 1000.0
|
||||
sun += max(0.0, pv - use)
|
||||
fc_sum += pv
|
||||
sun *= trust * EFF
|
||||
|
||||
usable = [p for p in packs if p.use and p.live and p.idle
|
||||
and p.soc is not None and p.capacity_kwh]
|
||||
sf = [p for p in usable if p.mode == SOLAR_FIRST]
|
||||
price = [p for p in usable if p.mode == LEFTOVER_SOLAR]
|
||||
sf_room = sum(_room(p, ceiling_pct) for p in sf)
|
||||
excess = max(0.0, sun - sf_room)
|
||||
rooms = {p.name: _room(p, ceiling_pct) for p in price}
|
||||
total_room = sum(rooms.values())
|
||||
|
||||
# What the house draws in the expensive runs from the one this plan is
|
||||
# for until the next cheap run (or a day), from the profile.
|
||||
horizon = until.start + timedelta(hours=24)
|
||||
use_kwh = 0.0
|
||||
for g in runs.give:
|
||||
if g.start < until.start or g.start >= horizon:
|
||||
continue
|
||||
for s, e, h in _hour_slices(g.start, g.end):
|
||||
use_kwh += max(0.0, house_w(h)) * (
|
||||
e - s).total_seconds() / 3600.0 / 1000.0
|
||||
caps = {p.name: float(p.capacity_kwh) for p in price}
|
||||
cap_sum = sum(caps.values()) or 1.0
|
||||
|
||||
targets, need, share = {}, {}, {}
|
||||
for p in price:
|
||||
sh = excess * rooms[p.name] / total_room if total_room > 0 else 0.0
|
||||
sh_pct = sh / caps[p.name] * 100.0
|
||||
want = use_kwh * caps[p.name] / cap_sum / EFF
|
||||
top = min(float(ceiling_pct),
|
||||
float(floor_pct) + want / caps[p.name] * 100.0)
|
||||
level = max(0.0, top - sh_pct)
|
||||
targets[p.name] = round(level, 2)
|
||||
need[p.name] = round(_room(p, level), 3)
|
||||
share[p.name] = round(sh, 3)
|
||||
if sun < sf_room:
|
||||
verdict = DARK
|
||||
elif any(v > 0.05 for v in need.values()):
|
||||
verdict = PARTLY
|
||||
else:
|
||||
verdict = SUNNY
|
||||
return Plan(verdict, round(sun, 3), round(fc_sum, 3), until.start,
|
||||
targets, need, share)
|
||||
|
||||
|
||||
def hold(old: dict | None, new: dict, capacity: dict) -> dict:
|
||||
"""Hysteresis: a battery keeps its old level unless the new one differs
|
||||
by at least `HYST_KWH`, or by `HYST_FRAC` of the larger level's energy
|
||||
(whichever is less). A battery new to the plan takes its level at once;
|
||||
one that left the plan is dropped at once."""
|
||||
out = {}
|
||||
for name, level in new.items():
|
||||
was = (old or {}).get(name)
|
||||
cap = float(capacity.get(name) or 0.0)
|
||||
if was is None or cap <= 0:
|
||||
out[name] = level
|
||||
continue
|
||||
moved = abs(level - was) / 100.0 * cap
|
||||
step = min(HYST_KWH, HYST_FRAC * max(was, level) / 100.0 * cap)
|
||||
out[name] = level if moved >= step else was
|
||||
return out
|
||||
@@ -87,6 +87,10 @@ when it has not moved THROUGH A CHANGE IT WAS OBLIGED TO FOLLOW:
|
||||
AND |standing command now - standing command when the reading
|
||||
last changed| >= MOVE_W
|
||||
|
||||
SAFETY-94: "unchanged for" counts only the reads at which both command terms
|
||||
held, so a register that rested is not judged before it could answer.
|
||||
DECISIONS/SAFETY-94-lagging-battery.md.
|
||||
|
||||
0x0518 is the inverter reporting ITSELF and it tracks its own command: r = 0.998
|
||||
with battery power against r = 0.09 with the real meter (goodwe/NOTES.md §3.3),
|
||||
command and actual agreeing within 4 W once settled (§5.10, 2026-08-22), and the
|
||||
@@ -216,6 +220,8 @@ change - which was the ONLY exit - has a median of 143 s, 17 episodes at or
|
||||
over the live one's 710 s, and a worst case of 21440 s. That distribution is a
|
||||
property of this battery's firmware. It is not a property of this code, and the
|
||||
add-on must not depend on it.
|
||||
SAFETY-94: many were the gate judging a rested register on its first read
|
||||
(SAFETY-58). Counted from the ask, the same days give 59 trips.
|
||||
|
||||
THE RULE, and it is SAFETY-13's shape one module over - "which latches get an
|
||||
exit, not how long the block lasts":
|
||||
@@ -372,7 +378,9 @@ BOUNDS = {
|
||||
"SAFETY-57: the verdict is withdrawn after 17.0 s of the "
|
||||
"standing command below 250 W, because at 0 W the register "
|
||||
"is obliged to nothing and the verdict cannot be tested "
|
||||
"again from inside the state it creates"),
|
||||
"again from inside the state it creates. SAFETY-94: the "
|
||||
"35 s counts only reads at which the command asks the "
|
||||
"register to move"),
|
||||
"soc": Bound(
|
||||
signal="soc (0x050E, pack SoC, U16, 1 %, 10 s publish)",
|
||||
unchanged_s=float("inf"),
|
||||
@@ -416,11 +424,9 @@ class Freshness:
|
||||
new grading window at that instant. The 1 Hz oscillation the latch exists to
|
||||
prevent is still prevented: the new window is `bound.unchanged_s` wide, so
|
||||
no re-trip can land sooner than 35 s after a release, rather than on the
|
||||
next read. ⚠️ MEASURED FROM THE RELEASE, NOT FROM THE COMMAND RESUMING - if
|
||||
the site rests for longer than the window before it asks for anything, the
|
||||
window is already old and the re-trip lands on the first read at which the
|
||||
command travels 250 W again. That is survivor 5's shape, it predates this
|
||||
card, and its cost is one `stale_input_s` hold.
|
||||
next read. SAFETY-94: the 35 s counts only while the command asks the
|
||||
register to move, so a site that rests after a release is not re-tripped
|
||||
on its first ask.
|
||||
|
||||
⚠️ TWO CLOCKS, AND THE DISTINCTION IS THE WHOLE OF SAFETY-57'S HONESTY.
|
||||
`changed_mono` / `held` are facts about the REGISTER: when it last carried a
|
||||
@@ -451,6 +457,11 @@ class Freshness:
|
||||
# the change-stamps; `_release()` is where they diverge.
|
||||
self.graded_from = None
|
||||
self.standing_at_grade = None
|
||||
# SAFETY-94. Seconds of this window during which the register was
|
||||
# obliged to move (the command at least `move_w` and `move_w` away
|
||||
# from `standing_at_grade`), and the instant of the last read.
|
||||
self.obliged_acc = 0.0
|
||||
self.last_read = None
|
||||
# The instant the standing command last FELL below `move_w`, or None
|
||||
# while an obligation is standing. The release timer runs off this.
|
||||
self.rested_since = None
|
||||
@@ -499,6 +510,7 @@ class Freshness:
|
||||
# it reads in the order the state machine moves - withdraw, then
|
||||
# re-grade - not because the code depends on it.
|
||||
self._release(standing_w, now_mono)
|
||||
self._oblige(standing_w, now_mono)
|
||||
self._grade(standing_w, now_mono)
|
||||
|
||||
def _open_window(self, standing_w, now_mono) -> None:
|
||||
@@ -510,6 +522,35 @@ class Freshness:
|
||||
self.graded_from = float(now_mono)
|
||||
self.standing_at_grade = (None if standing_w is None
|
||||
else float(standing_w))
|
||||
# The read that opens a window is never an ask (no travel yet).
|
||||
self.obliged_acc = 0.0
|
||||
|
||||
def _obliged(self, standing_w) -> bool:
|
||||
"""Is the register asked to move: the command is at least `move_w` and
|
||||
has travelled `move_w` since the window opened?"""
|
||||
if standing_w is None or self.standing_at_grade is None:
|
||||
return False
|
||||
standing_w = float(standing_w)
|
||||
return (abs(standing_w) >= self.bound.move_w
|
||||
and abs(standing_w - self.standing_at_grade)
|
||||
>= self.bound.move_w)
|
||||
|
||||
def _oblige(self, standing_w, now_mono) -> None:
|
||||
"""SAFETY-94. Count only the time the register was asked to move.
|
||||
|
||||
A register that held still while nothing asked it to move has not
|
||||
failed, so time before the command moved is not evidence. The time
|
||||
since the previous read counts when the obligation stands at this
|
||||
read; a command flapping in and out of the obligation still adds up.
|
||||
"""
|
||||
now_mono = float(now_mono)
|
||||
if self.last_read is not None and self._obliged(standing_w):
|
||||
self.obliged_acc += max(0.0, now_mono - self.last_read)
|
||||
self.last_read = now_mono
|
||||
|
||||
def obliged_s(self) -> float:
|
||||
"""Seconds of the current window the register was obliged to move."""
|
||||
return self.obliged_acc
|
||||
|
||||
def _release(self, standing_w, now_mono) -> None:
|
||||
"""SAFETY-57. Withdraw a verdict whose obligation is no longer standing.
|
||||
@@ -543,7 +584,12 @@ class Freshness:
|
||||
if self.stale or self.graded_from is None:
|
||||
return
|
||||
held_s = self.graded_s(now_mono)
|
||||
if held_s < self.bound.unchanged_s:
|
||||
# SAFETY-94 (closes SAFETY-58): the bound counts only the time the
|
||||
# command asked the register to move, not the time since it last
|
||||
# changed. A register that rested for minutes was otherwise judged on
|
||||
# the first read after a new command, before it could answer (live,
|
||||
# 2026-10-03: 1 s after the command).
|
||||
if self.obliged_s() < self.bound.unchanged_s:
|
||||
return
|
||||
# ⚠️ BOTH None GUARDS ARE FOR A CALLER THAT DOES NOT KNOW ITS OWN
|
||||
# OBLIGATION YET, WHICH IS NOT `_read_unit`. `Inverter.standing_w()`
|
||||
|
||||
@@ -11,6 +11,8 @@ import time
|
||||
|
||||
import aiohttp
|
||||
|
||||
from . import messages
|
||||
|
||||
_LOG = logging.getLogger("goodwe.hass")
|
||||
|
||||
CORE_API = "http://supervisor/core/api"
|
||||
@@ -19,6 +21,7 @@ BAD_STATES = ("unknown", "unavailable", "none", "")
|
||||
# What the Supervisor's proxy answers while Home Assistant restarts.
|
||||
UNAVAILABLE = (502, 503, 504)
|
||||
STATES_TIMEOUT_S = 10 # UX-13's entity list, like every other read here
|
||||
STILL_WAITING_S = 300 # SAFETY-112: one reminder line per 5 minutes down
|
||||
|
||||
|
||||
class Outage:
|
||||
@@ -29,15 +32,30 @@ class Outage:
|
||||
("502, message='Bad Gateway', url=URL(...)", "Received message 8:1000 is
|
||||
not str"). Now the first channel to fail says it once at WARNING, the raw
|
||||
text goes to DEBUG, and the last channel to recover says so at INFO.
|
||||
|
||||
SAFETY-112: the Supervisor answers 502 for every read, write and
|
||||
websocket until Home Assistant has finished starting, however live its
|
||||
entities already are (DECISIONS/SAFETY-112-waiting-for-home-assistant.md).
|
||||
So an outage also says, every STILL_WAITING_S, that it is still on, and
|
||||
`waiting()` puts it on the status page.
|
||||
"""
|
||||
|
||||
def __init__(self):
|
||||
self.down_on = set()
|
||||
self.since = None # monotonic start of this outage
|
||||
self._told = None # when the last "still waiting" line went
|
||||
|
||||
def down(self, channel: str, what: str, detail) -> None:
|
||||
now = time.monotonic()
|
||||
if not self.down_on:
|
||||
_LOG.warning("Home Assistant is not answering (%s), perhaps it is "
|
||||
"restarting. The add-on keeps trying.", what)
|
||||
"still starting. Control waits and resumes by itself.",
|
||||
what)
|
||||
self.since = self._told = now
|
||||
elif now - self._told >= STILL_WAITING_S:
|
||||
self._told = now
|
||||
_LOG.info("Still waiting for Home Assistant to finish starting, "
|
||||
"%s so far.", messages.duration(now - self.since))
|
||||
self.down_on.add(channel)
|
||||
_LOG.debug("Home Assistant not answering on %s: %s", channel, detail)
|
||||
|
||||
@@ -45,7 +63,13 @@ class Outage:
|
||||
if channel in self.down_on:
|
||||
self.down_on.discard(channel)
|
||||
if not self.down_on:
|
||||
_LOG.info("Home Assistant answers again.")
|
||||
_LOG.info("Home Assistant answers again after %s.",
|
||||
messages.duration(time.monotonic() - self.since))
|
||||
|
||||
def waiting(self) -> bool:
|
||||
"""True while Home Assistant's API does not answer. The API, not the
|
||||
meter websocket: every battery reading and every write rides on it."""
|
||||
return "api" in self.down_on
|
||||
|
||||
|
||||
OUTAGE = Outage()
|
||||
|
||||
@@ -20,7 +20,7 @@ from datetime import datetime, timedelta, timezone
|
||||
|
||||
from . import arbitrage, messages, peakguard, uitext
|
||||
from .maintenance import CHARGE as M_CHARGE, DRAIN as M_DRAIN, HOLD as M_HOLD
|
||||
from .maintenance import IDLE as M_IDLE
|
||||
from .maintenance import IDLE as M_IDLE, next_slot_start
|
||||
from .packmode import CHEAP_HOURS, GRID_CHARGE_MODES, LEFTOVER_SOLAR, SOLAR_FIRST
|
||||
from .price import Absence, Uncertainty, brussels
|
||||
from .static_tariff import static_plan
|
||||
@@ -345,7 +345,10 @@ def mode_runs(c, day0, day1, now, shadow):
|
||||
else (soc - floor)) / 100.0 * cap)
|
||||
return kwh
|
||||
blocks = []
|
||||
if rp.charge_useful() and pm.mode in GRID_CHARGE_MODES:
|
||||
# P4: with a day plan, the grid block is the planned shortfall.
|
||||
need = plan_need(c, inv.name)
|
||||
if rp.charge_useful() and (need > 0.0 if need is not None
|
||||
else pm.mode in GRID_CHARGE_MODES):
|
||||
blocks.append(("grid", rp.cheap))
|
||||
sell = rp.sell if pm.sell and pm.can_sell else None
|
||||
for g in rp.give:
|
||||
@@ -358,6 +361,8 @@ def mode_runs(c, day0, day1, now, shadow):
|
||||
continue
|
||||
hrs = (run.end - run.start).total_seconds() / 3600.0
|
||||
kwh = room(kind, hrs)
|
||||
if kind == "grid" and need is not None:
|
||||
kwh = min(kwh, need)
|
||||
if kwh < MIN_KWH:
|
||||
continue
|
||||
price = run.mean_eur_kwh
|
||||
@@ -382,10 +387,60 @@ def mode_runs(c, day0, day1, now, shadow):
|
||||
return out, None
|
||||
|
||||
|
||||
def plan_need(c, name):
|
||||
"""P4: kWh this battery buys from the grid by the day plan, or None when
|
||||
there is no plan for it (then P3 option A applies)."""
|
||||
targets = c.plan_targets() if hasattr(c, "plan_targets") else None
|
||||
if not targets or name not in targets:
|
||||
return None
|
||||
inv = next((i for i in c.inverters if i.name == name), None)
|
||||
if inv is None or inv.soc is None or not inv.capacity_kwh:
|
||||
return None
|
||||
return max(0.0, targets[name] - float(inv.soc)) / 100.0 * float(
|
||||
inv.capacity_kwh)
|
||||
|
||||
|
||||
def plan_state(c):
|
||||
"""P4: `"plan"` (a day plan is made), `"learning"` (no house profile
|
||||
yet), `"no_forecast"` (set but missing or stale), or None (not set, or
|
||||
battery modes off)."""
|
||||
if not getattr(c, "modes_on", False) or \
|
||||
getattr(c, "fc_entity", None) is None:
|
||||
return None
|
||||
if getattr(c, "solar_fc", None) is None:
|
||||
return "no_forecast"
|
||||
hp = getattr(c, "house_profile", None)
|
||||
if hp is not None and not hp.ready():
|
||||
return "learning"
|
||||
return "plan" if getattr(c, "day_plan", None) is not None else None
|
||||
|
||||
|
||||
def solar_block(c, now):
|
||||
"""P4: the solar forecast line for the Batteries screen and the Simple
|
||||
settings view: `{state, fc_kwh, count_kwh, updated, line}`."""
|
||||
st = plan_state(c)
|
||||
out = {"state": st, "fc_kwh": None, "count_kwh": None, "updated": None,
|
||||
"line": ""}
|
||||
if st is None and getattr(c, "solar_fc", None) is None:
|
||||
return out
|
||||
fc = getattr(c, "solar_fc", None)
|
||||
if fc is not None:
|
||||
trust = float(getattr(c, "solar_trust_pct", 70)) / 100.0
|
||||
out.update(fc_kwh=round(fc.today.kwh, 1),
|
||||
count_kwh=round(fc.today.kwh * trust, 1),
|
||||
updated=hhmm(fc.at))
|
||||
if st in ("no_forecast", "learning"):
|
||||
out["line"] = _t("solar." + st)
|
||||
elif fc is not None:
|
||||
out["line"] = line_solar(fc.today.kwh, out["count_kwh"],
|
||||
out["updated"])
|
||||
return out
|
||||
|
||||
|
||||
def maintenance_runs(c, day0, day1, now, shadow):
|
||||
"""The monthly battery cycle: under way now, or starting later today.
|
||||
The cycle starts in the hour `maintenance_start_hour` names, read as the
|
||||
control cycle reads it (UTC hour of `now`), shown in local time."""
|
||||
The cycle starts in the hour `maintenance_start_hour` names, read in the
|
||||
site's zone exactly as the control cycle reads it (MAINT-10)."""
|
||||
runs, lines = [], []
|
||||
waiting = []
|
||||
for i, (inv, m) in enumerate(zip(c.inverters, c.maints)):
|
||||
@@ -404,10 +459,9 @@ def maintenance_runs(c, day0, day1, now, shadow):
|
||||
if not m.due(now) and (m.next_due(now) is None
|
||||
or m.next_due(now) >= day1):
|
||||
continue
|
||||
start = now.replace(hour=cfg.start_hour, minute=0, second=0,
|
||||
microsecond=0)
|
||||
if start + timedelta(hours=1) <= now:
|
||||
start += timedelta(days=1)
|
||||
start = next_slot_start(now, cfg.start_hour, m.tz)
|
||||
if start is None:
|
||||
continue
|
||||
due_at = m.next_due(now)
|
||||
if due_at is not None and due_at > start:
|
||||
continue
|
||||
@@ -640,6 +694,14 @@ def battery_rows(c, shadow, running, held=False):
|
||||
# carries its share (SAFETY-73)?
|
||||
other = next((o.name for o in c.inverters if o is not inv
|
||||
and refusing(c, o) > 0 and not _off(c, o)), None)
|
||||
# SAFETY-78: another battery drains for its monthly cycle, so this
|
||||
# one never charges now. Not while that drain waits: it files no
|
||||
# floor then, so this battery may charge from solar.
|
||||
waits = getattr(c, "_drain_waits", ())
|
||||
cycling = next((o.name for j, o in enumerate(c.inverters)
|
||||
if o is not inv and j < len(c.maints)
|
||||
and c.maints[j].phase == M_DRAIN
|
||||
and o.name not in waits), None)
|
||||
role = None if tick is None else tick.roles.get(inv.name)
|
||||
# Only once a cycle has run with modes on (`tick`): before that
|
||||
# nothing is known, so nothing is claimed about the prices.
|
||||
@@ -655,7 +717,10 @@ def battery_rows(c, shadow, running, held=False):
|
||||
phase=phase, shadow=shadow, running=running, held=held,
|
||||
refused=refusing(c, inv), peak=peak,
|
||||
giving=flow(inv.batt) == "giving", other_refuses=other,
|
||||
sf_ahead=sf_ahead, role=role, plan=plan, has_at=bool(at))
|
||||
sf_ahead=sf_ahead, role=role, plan=plan, has_at=bool(at),
|
||||
other_cycle=cycling,
|
||||
day=None if pm is None or pm.mode not in PRICE_MODES
|
||||
else day_key(c, inv.name))
|
||||
rows.append({
|
||||
"name": inv.name,
|
||||
"level_pct": None if inv.soc is None else float(inv.soc),
|
||||
@@ -673,7 +738,8 @@ def battery_rows(c, shadow, running, held=False):
|
||||
# UX-13 P3: why it does what "now" says, from what the add-on
|
||||
# knows this cycle. Price and forecast reasons are OPT-11 P3/P4.
|
||||
"why_key": why,
|
||||
"why": why_words(why, name=other, at=at),
|
||||
"why": why_words(why, name=cycling if why == "other_cycle"
|
||||
else other, at=at),
|
||||
})
|
||||
if modes_on:
|
||||
# OPT-11 P1: the battery's switch and mode, for the Batteries
|
||||
@@ -689,10 +755,25 @@ def battery_rows(c, shadow, running, held=False):
|
||||
return rows
|
||||
|
||||
|
||||
def day_key(c, name):
|
||||
"""P4: the day plan's word for one Leftover solar or Cheap hours
|
||||
battery: `sun_fills`, `tops_up`, `no_forecast`, or None."""
|
||||
st = plan_state(c)
|
||||
if st == "no_forecast":
|
||||
mode = c.pack_mode(next(i for i in c.inverters if i.name == name))
|
||||
return "no_forecast" if mode.mode == LEFTOVER_SOLAR else None
|
||||
if st != "plan":
|
||||
return None
|
||||
need = plan_need(c, name)
|
||||
if need is None:
|
||||
return None
|
||||
return "tops_up" if need >= MIN_KWH else "sun_fills"
|
||||
|
||||
|
||||
def battery_why(*, modes_on, mode, off, reading, phase, shadow, running,
|
||||
held, refused, peak, sf_ahead, giving=False,
|
||||
other_refuses=None, role=None, plan=None,
|
||||
has_at=False) -> str:
|
||||
has_at=False, other_cycle=None, day=None) -> str:
|
||||
"""The key of one battery's "why" line (`home_words.why`), most urgent
|
||||
first. Pure, so every branch is tested without a controller."""
|
||||
if not reading:
|
||||
@@ -712,11 +793,15 @@ def battery_why(*, modes_on, mode, off, reading, phase, shadow, running,
|
||||
return "refuses_give" if refused > 0 else "refuses_charge"
|
||||
if peak:
|
||||
return "peak"
|
||||
if other_cycle:
|
||||
return "other_cycle"
|
||||
if giving and other_refuses:
|
||||
return "other_refuses"
|
||||
if not modes_on:
|
||||
return "modes_off"
|
||||
# OPT-11 P3: the battery's role in the price runs this cycle.
|
||||
if role == "hold" and day is not None:
|
||||
return day # P4: what the day plan decided
|
||||
if role in ROLE_WHY:
|
||||
if role == "hold" and not has_at:
|
||||
return "saves_later"
|
||||
@@ -818,17 +903,20 @@ def month_peak(c, now):
|
||||
if pg is not None:
|
||||
out["period_w"] = pg.projected_w
|
||||
ceiling = pg.ceiling_w or limit_w
|
||||
out["line"] = line_period(out["period_w"], ceiling, c.shadow)
|
||||
out["line"] = line_period(out["period_w"], ceiling, c.shadow,
|
||||
unmeasured=getattr(c, "peak_unmeasured_s", 0.0)
|
||||
> 0.0)
|
||||
return out
|
||||
|
||||
|
||||
def state_of(c, level, shadow):
|
||||
def state_of(c, level, shadow, waiting=False):
|
||||
"""One word for the pill and the banner's colour: running, shadow,
|
||||
stopped, alarm or warning."""
|
||||
stopped, alarm, waiting or warning. `waiting`: the red headline is
|
||||
Home Assistant still starting (SAFETY-112), which needs nobody."""
|
||||
if shadow:
|
||||
return "shadow"
|
||||
if level == "bad":
|
||||
return "alarm"
|
||||
return "waiting" if waiting else "alarm"
|
||||
if not c.auto:
|
||||
return "stopped"
|
||||
if level == "warn":
|
||||
@@ -837,24 +925,27 @@ def state_of(c, level, shadow):
|
||||
|
||||
|
||||
def build(c, *, level: str, checks: list, now: datetime | None = None,
|
||||
lang: str = "en") -> dict:
|
||||
lang: str = "en", held: bool | None = None,
|
||||
waiting: bool = False) -> dict:
|
||||
"""The structured half of `/status`, in `lang` (UX-13 P5). Pure reads of
|
||||
the controller."""
|
||||
_LANG[0] = uitext.lang_of(lang)
|
||||
try:
|
||||
return _build(c, level=level, checks=checks, now=now)
|
||||
return _build(c, level=level, checks=checks, now=now, held=held,
|
||||
waiting=waiting)
|
||||
finally:
|
||||
_LANG[0] = "en"
|
||||
|
||||
|
||||
def _build(c, *, level, checks, now):
|
||||
def _build(c, *, level, checks, now, held=None, waiting=False):
|
||||
now = now or datetime.now(timezone.utc)
|
||||
shadow = bool(c.shadow)
|
||||
kind = state_of(c, level, shadow)
|
||||
kind = state_of(c, level, shadow, waiting)
|
||||
# A red banner means every inverter is at 0 W (the status cascade), so
|
||||
# nothing is planned until it clears. Shadow mode still plans: it is
|
||||
# what the add-on would do.
|
||||
held = level == "bad" and not shadow
|
||||
# what the add-on would do. `held` False: an alarm while control runs
|
||||
# (SAFETY-87, the peak alarms).
|
||||
held = level == "bad" and not shadow and held is not False
|
||||
running = (bool(c.auto) or shadow) and not held
|
||||
settled = all(at_zero(inv) for inv in c.inverters)
|
||||
ctl = next((r for r in checks if r.get("id") == "controller"), None)
|
||||
@@ -864,6 +955,7 @@ def _build(c, *, level, checks, now):
|
||||
modes_on=bool(getattr(c, "modes_on", False)),
|
||||
running=running, held=held, shadow=shadow)
|
||||
return {
|
||||
"solar": solar_block(c, now),
|
||||
"state": {"kind": kind, "pill": pill(kind),
|
||||
"ran": ctl.get("text", "") if ctl else "",
|
||||
"sub": banner_sub(kind)},
|
||||
@@ -1160,6 +1252,10 @@ def run_house_amount() -> str:
|
||||
return _t("run.house_amount")
|
||||
|
||||
|
||||
def line_solar(fc_kwh, count_kwh, at) -> str:
|
||||
return _t("solar.line", kwh=_kwh(fc_kwh), count=_kwh(count_kwh), at=at)
|
||||
|
||||
|
||||
def line_no_trade(key) -> str:
|
||||
return "" if key == "off" else _t("no_trade." + key)
|
||||
|
||||
@@ -1202,8 +1298,11 @@ def line_peak_not_covered() -> str:
|
||||
return _t("peak_not_covered")
|
||||
|
||||
|
||||
def line_period(period_w, limit_w, shadow) -> str:
|
||||
def line_period(period_w, limit_w, shadow, unmeasured=False) -> str:
|
||||
step = _w(shadow, "step_in", kw=_kw(limit_w))
|
||||
if unmeasured:
|
||||
# SAFETY-90: the add-on started during this period.
|
||||
return _t("period_unmeasured") + " " + step
|
||||
if period_w is None:
|
||||
return step
|
||||
return _t("period", kw=_kw(period_w)) + " " + step
|
||||
@@ -1236,7 +1335,7 @@ def _samples() -> list:
|
||||
out += [("title", mode_word(k)) for k in words["modes"]]
|
||||
out += [("title", mode_house()), ("title", attn_shadow()),
|
||||
("line", attn_shadow_body())]
|
||||
for k in ("running", "shadow", "stopped", "alarm", "warning"):
|
||||
for k in ("running", "shadow", "stopped", "alarm", "waiting", "warning"):
|
||||
out += [("title", pill(k)), ("line", banner_sub(k))]
|
||||
for sh in (False, True):
|
||||
out += [("title", tile_solar(v, s)) for v, s in
|
||||
@@ -1277,6 +1376,7 @@ def _samples() -> list:
|
||||
("plan", line_peak_limit(3500, sh)),
|
||||
("plan", line_period(1240, 3500, sh)),
|
||||
("plan", line_period(None, 3500, sh)),
|
||||
("plan", line_period(1240, 3500, sh, unmeasured=True)),
|
||||
("plan", control_text(True, sh)),
|
||||
("plan", control_text(False, sh))]
|
||||
out += [("plan", run_grid_why(0.1412)), ("plan", run_grid_amount(1.23)),
|
||||
@@ -1302,6 +1402,8 @@ def _samples() -> list:
|
||||
off=off, peak=peak)))
|
||||
out += [("plan", why_words(k, name="Battery A")) for k in words["why"]]
|
||||
out += [("plan", today_words(k)) for k in words["today"]]
|
||||
out += [("plan", line_solar(9.2, 6.4, "10:15")),
|
||||
("plan", _t("solar.no_forecast")), ("plan", _t("solar.learning"))]
|
||||
out += [("plan", line_no_trade(k)) for k in
|
||||
("not_covered", "no_prices", "peak", "not_firm", "not_worth",
|
||||
"no_level")]
|
||||
|
||||
@@ -0,0 +1,87 @@
|
||||
"""SAFETY-97: what a battery's power reading shows while it gives nothing.
|
||||
|
||||
B's reading (0x0518) shows -95 to -118 W at idle (standby draw, live
|
||||
2026-10-03); A's shows -2 to -4 W. "The battery gives nothing" is graded
|
||||
against this idle reading, not against 0 W, or a refusing B never latches.
|
||||
DECISIONS/SAFETY-97-idle-offset.md.
|
||||
|
||||
Learned per unit, never configured:
|
||||
- only while control runs, the unit is not refused, stale or tripped, and
|
||||
its command has been within IDLE_ASK_W for IDLE_QUIET_S (a refusing battery
|
||||
is asked more than that, so it cannot teach its refusal as idle);
|
||||
- a reading beyond IDLE_SAMPLE_W is not a sample;
|
||||
- first value: the mean of IDLE_FIRST_S of samples; then a slow follow
|
||||
(IDLE_TAU_S);
|
||||
- persisted per unit and restored, clamped to IDLE_SAMPLE_W, at start.
|
||||
The band is centred on it clamped to IDLE_MAX_W (owner, 2026-10-04). Until
|
||||
learned the idle reading is 0 W, the rule as it was.
|
||||
"""
|
||||
|
||||
import math
|
||||
|
||||
IDLE_MAX_W = 75.0 # |idle| used: under the 100 W band, so it keeps 0 W +-25 W
|
||||
IDLE_SAMPLE_W = 250.0 # a reading beyond this is not a sample
|
||||
IDLE_ASK_W = 50.0 # a command this small counts as "asked ~0"
|
||||
IDLE_QUIET_S = 120.0 # 6 lags of 20 s: a 2500 W step has decayed to 6 W
|
||||
IDLE_FIRST_S = 120.0 # seconds of samples averaged for the first value
|
||||
IDLE_TAU_S = 1800.0 # then follow drift this slowly
|
||||
IDLE_SAVE_W = 5.0 # persist when the value moved this far
|
||||
IDLE_GAP_S = 10.0 # a longer gap between reads counts as this
|
||||
|
||||
|
||||
def _num(v):
|
||||
try:
|
||||
v = float(v)
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
return v if math.isfinite(v) else None
|
||||
|
||||
|
||||
class IdleReading:
|
||||
"""One unit's idle reading. `w` is what "gives nothing" is centred on."""
|
||||
|
||||
def __init__(self, saved=None):
|
||||
v = _num(saved)
|
||||
self.value = (None if v is None
|
||||
else max(-IDLE_SAMPLE_W, min(IDLE_SAMPLE_W, v)))
|
||||
self.saved = self.value
|
||||
self.quiet_since = None
|
||||
self.last = None
|
||||
self.acc_w = 0.0
|
||||
self.acc_s = 0.0
|
||||
|
||||
@property
|
||||
def w(self) -> float:
|
||||
"""The centre used: the learned value clamped to IDLE_MAX_W."""
|
||||
if self.value is None:
|
||||
return 0.0
|
||||
return max(-IDLE_MAX_W, min(IDLE_MAX_W, self.value))
|
||||
|
||||
def observe(self, reading, standing_w, now_mono, may_learn) -> bool:
|
||||
"""One read. Returns True when the value should be persisted."""
|
||||
now = float(now_mono)
|
||||
dt = (0.0 if self.last is None
|
||||
else max(0.0, min(IDLE_GAP_S, now - self.last)))
|
||||
self.last = now
|
||||
standing = _num(standing_w)
|
||||
if not may_learn or standing is None or abs(standing) > IDLE_ASK_W:
|
||||
self.quiet_since = None
|
||||
return False
|
||||
if self.quiet_since is None:
|
||||
self.quiet_since = now
|
||||
b = _num(reading)
|
||||
if (now - self.quiet_since < IDLE_QUIET_S or b is None
|
||||
or abs(b) > IDLE_SAMPLE_W or dt <= 0.0):
|
||||
return False
|
||||
if self.value is None:
|
||||
self.acc_w += b * dt
|
||||
self.acc_s += dt
|
||||
if self.acc_s < IDLE_FIRST_S:
|
||||
return False
|
||||
self.value = self.acc_w / self.acc_s
|
||||
else:
|
||||
self.value += (b - self.value) * min(1.0, dt / IDLE_TAU_S)
|
||||
if self.saved is None or abs(self.value - self.saved) >= IDLE_SAVE_W:
|
||||
self.saved = self.value
|
||||
return True
|
||||
return False
|
||||
@@ -127,6 +127,7 @@ from . import messages
|
||||
# SAFETY-37. The freshness policy, and the ONE place its bounds are written.
|
||||
# freshness.py imports nothing from this package, so the direction is one-way.
|
||||
from .freshness import BOUNDS, Freshness
|
||||
from .idle import IdleReading
|
||||
# CFG-03's ONE in-code mirror of config.yaml's SAFETY-24 defaults. Imported
|
||||
# rather than retyped: the flat-keys path below needs `bms_soc_floor`'s
|
||||
# shipped default and a literal here would be the fourth defaults site that
|
||||
@@ -321,13 +322,21 @@ class Inverter:
|
||||
# take, 0 none), when that refusal or its last probe started, the
|
||||
# current probe's start, and the cycles of evidence so far and when
|
||||
# they began. Memory only, like SAFETY-52's: stop and start end it.
|
||||
# Used at N>1 only.
|
||||
# The evidence count is also used at N=1 (SAFETY-94); the rest at N>1.
|
||||
self.refused = 0
|
||||
self.refused_at = None
|
||||
self.probe_from = None
|
||||
self.ref_count = 0
|
||||
self.ref_since = None
|
||||
self.ref_sign = 0
|
||||
self.ref_from = None
|
||||
# SAFETY-97: what this unit's reading shows at idle; "gives nothing"
|
||||
# is centred on it. Learned, persisted, restored (app/idle.py).
|
||||
self.idle = IdleReading(data.get(self.key("idle_w")))
|
||||
|
||||
@property
|
||||
def idle_w(self) -> float:
|
||||
return self.idle.w
|
||||
|
||||
# -- store ---------------------------------------------------------------
|
||||
def key(self, name: str) -> str:
|
||||
|
||||
+1225
-93
File diff suppressed because it is too large
Load Diff
@@ -34,7 +34,7 @@ simply not do.
|
||||
import logging
|
||||
import math
|
||||
from dataclasses import dataclass, field
|
||||
from datetime import datetime, timedelta, timezone
|
||||
from datetime import datetime, timedelta, timezone, tzinfo
|
||||
|
||||
from .store import MAINT_UNIT_KEYS, unit_key
|
||||
|
||||
@@ -65,10 +65,30 @@ POWER_MOVING = (DRAIN, CHARGE, HOLD)
|
||||
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# it is expected to span a night; 36 h still bounds it.
|
||||
DRAIN_TIMEOUT_MIN = 720
|
||||
# MAINT-13: minutes the pack was ALLOWED to charge (the price gate open), not
|
||||
# wall-clock minutes since the charge began. See CHARGE_WALL_TIMEOUT_MIN.
|
||||
CHARGE_TIMEOUT_MIN = 2160
|
||||
# After an abort, do not immediately re-trigger in the same start hour.
|
||||
RESTART_COOLDOWN_MIN = 90
|
||||
|
||||
# MAINT-13 (DECISIONS/MAINT-13-full-pack-is-complete.md). Constants, not options.
|
||||
# A pack that reaches target - 3 and then takes no more charge for this many
|
||||
# minutes of allowed charging counts as full.
|
||||
CHARGE_NEAR_FULL_PCT = 3
|
||||
CHARGE_STALL_MIN = 60
|
||||
# Wall-clock backstop for a charge whose gate never opens (no cheap hours, no sun).
|
||||
CHARGE_WALL_TIMEOUT_MIN = 10080
|
||||
# A failed cycle (stuck drain or charge) is not retried before this many days.
|
||||
FAIL_BACKOFF_DAYS = 7
|
||||
# One tick counts at most this many minutes: a gap means the add-on was down.
|
||||
CHARGE_TICK_MAX_MIN = 5
|
||||
# The charge accounting is written to the state file at most this often.
|
||||
CHARGE_SAVE_MIN = 5
|
||||
# MAINT-14 (DECISIONS/MAINT-14-no-soc-in-maintenance.md): with no SoC reading
|
||||
# the timeouts still run, a drain holds at 0 W, and the log says once, after this
|
||||
# many minutes, that the level has been unknown for long.
|
||||
NOSOC_NOTE_MIN = 15
|
||||
|
||||
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
|
||||
# OPTION, and the only place in the add-on where one of these numbers is typed.
|
||||
#
|
||||
@@ -112,7 +132,9 @@ RESTART_COOLDOWN_MIN = 90
|
||||
MAINT_OPTION_DEFAULTS = {
|
||||
"maintenance_enabled": False,
|
||||
"maintenance_interval_days": 28,
|
||||
"maintenance_start_hour": 10,
|
||||
# MAINT-10: a LOCAL hour (site_zone() below), 19:00 so the drain runs
|
||||
# into the night rather than through the solar day.
|
||||
"maintenance_start_hour": 19,
|
||||
# ⚠️ 2000, NOT THE 2500 THIS SHIPPED AS, and config.yaml carries the
|
||||
# argument: both rates must stay at or below `max_w` (2000) or the
|
||||
# cheap-window charge shaping asks the arbiter for `hi = -charge_w` against
|
||||
@@ -177,6 +199,69 @@ class MaintConfig:
|
||||
)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# MAINT-10: the start hour is local time. See DECISIONS/MAINT-10-local-start-hour.md.
|
||||
# --------------------------------------------------------------------------- #
|
||||
def _load_zone(name):
|
||||
"""A tzinfo for an IANA name, or `(None, why)`."""
|
||||
if not name or not isinstance(name, str):
|
||||
return None, "none given"
|
||||
try:
|
||||
from zoneinfo import ZoneInfo
|
||||
return ZoneInfo(name.strip()), ""
|
||||
except Exception as err: # noqa: BLE001 - any failure
|
||||
return None, f"{name!r} is not a known zone ({type(err).__name__})"
|
||||
|
||||
|
||||
def site_zone(ha_zone, ha_why: str, env_tz) -> tuple:
|
||||
"""`(tzinfo, name, source, why)`: Home Assistant's zone (source "ha"), else
|
||||
the container's TZ ("tz"), else UTC ("utc"). `why` says what was missing."""
|
||||
tz, why = _load_zone(ha_zone)
|
||||
if tz is not None:
|
||||
return tz, ha_zone, "ha", ""
|
||||
ha_why = ha_why or why
|
||||
tz, env_why = _load_zone(env_tz)
|
||||
if tz is not None:
|
||||
return tz, env_tz, "tz", ha_why
|
||||
return timezone.utc, "UTC", "utc", f"Home Assistant: {ha_why}, TZ: {env_why}"
|
||||
|
||||
|
||||
def in_start_slot(now: datetime, start_hour: int, tz: tzinfo) -> bool:
|
||||
"""Is `now` inside today's one-hour start slot, read on the local clock?
|
||||
|
||||
Normally the slot is the local hour `start_hour`. On the day the clocks go
|
||||
forward and that hour does not exist, it is the first hour after the jump.
|
||||
On the day they go back and it happens twice, only the first one counts.
|
||||
Worked from UTC instants only (`astimezone`), so it does not depend on how
|
||||
a tzinfo resolves a wall time that is missing or doubled.
|
||||
"""
|
||||
if now.tzinfo is None:
|
||||
now = now.replace(tzinfo=timezone.utc)
|
||||
here = now.astimezone(tz).replace(tzinfo=None)
|
||||
before = (now - timedelta(hours=1)).astimezone(tz).replace(tzinfo=None)
|
||||
if here.hour == start_hour:
|
||||
# the second pass through a repeated hour: an hour ago read the same
|
||||
return not (before.date() == here.date() and before.hour == start_hour)
|
||||
slot = here.replace(hour=start_hour, minute=0, second=0, microsecond=0)
|
||||
# the clock jumped over the start of the slot within the last hour
|
||||
return before < slot and here >= slot + timedelta(hours=1)
|
||||
|
||||
|
||||
def next_slot_start(now: datetime, start_hour: int, tz: tzinfo):
|
||||
"""The start of the slot `now` is in, or else of the next one; None if
|
||||
there is none within 50 h (no real zone does that)."""
|
||||
step = timedelta(minutes=15)
|
||||
t = now.replace(minute=now.minute - now.minute % 15, second=0,
|
||||
microsecond=0) - timedelta(hours=1)
|
||||
for _ in range(4 * 50):
|
||||
if (in_start_slot(t, start_hour, tz)
|
||||
and not in_start_slot(t - step, start_hour, tz)
|
||||
and t + timedelta(hours=1) > now):
|
||||
return t
|
||||
t += step
|
||||
return None
|
||||
|
||||
|
||||
@dataclass
|
||||
class MaintResult:
|
||||
phase: str
|
||||
@@ -192,6 +277,9 @@ class MaintResult:
|
||||
# showing an idle machine and a due date in the past. Empty on every path
|
||||
# that is not deferring, so a roster of one never sees it.
|
||||
deferred: str = ""
|
||||
# MAINT-13: "drain" or "charge" on the one tick where a cycle FAILED, so
|
||||
# the Controller can tell the operator once. Empty on every other tick.
|
||||
failed: str = ""
|
||||
|
||||
|
||||
class UnitHistory:
|
||||
@@ -256,8 +344,12 @@ class Maintenance:
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: MaintConfig, store, unit: str | None = None,
|
||||
name: str = "", mirror_flat: bool = False):
|
||||
name: str = "", mirror_flat: bool = False,
|
||||
tz: tzinfo | None = None):
|
||||
self.cfg = cfg
|
||||
# MAINT-10: the zone `cfg.start_hour` is read in - main.py resolves it
|
||||
# once at startup (`site_zone()`). UTC when nobody says, as before.
|
||||
self.tz = tz or timezone.utc
|
||||
# ⚠️ `self.store` IS THE VIEW, NOT THE Store. Everything in this class
|
||||
# names an UNQUALIFIED key - "phase", "last_completed" - and the view is
|
||||
# the one place that turns it into the key this pack owns. A raw
|
||||
@@ -275,6 +367,14 @@ class Maintenance:
|
||||
# per cycle would flush the very context that explains it. Same pattern
|
||||
# as `Controller._arb_action` and `_maint_shape_suspended`.
|
||||
self._deferred = ""
|
||||
# MAINT-13: the charge accounting (see _charge_account), in memory and
|
||||
# written to the state file every CHARGE_SAVE_MIN minutes.
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
# MAINT-14: when the SoC reading went missing (None while it is there),
|
||||
# and whether the "unknown for long" line was said in this episode.
|
||||
self._nosoc_since = None
|
||||
self._nosoc_said = False
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
@@ -282,6 +382,11 @@ class Maintenance:
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self._nosoc_since = None
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
if self.store.get("charge_track") is not None:
|
||||
self.store.set("charge_track", None)
|
||||
self.store.set("phase", phase)
|
||||
self.store.set_time("phase_started", now)
|
||||
_LOG.info("%s", msg)
|
||||
@@ -322,6 +427,21 @@ class Maintenance:
|
||||
return (last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN))
|
||||
|
||||
def backoff_until(self, now: datetime):
|
||||
"""MAINT-13: when a failed cycle may be tried again, or None.
|
||||
|
||||
None when nothing failed, when the back-off is over, or when a cycle
|
||||
completed after the failure (a forced start that worked ends it).
|
||||
"""
|
||||
failed = self.store.get_time("last_failed")
|
||||
if failed is None:
|
||||
return None
|
||||
done = self.store.get_time("last_completed")
|
||||
if done is not None and done >= failed:
|
||||
return None
|
||||
until = failed + timedelta(days=FAIL_BACKOFF_DAYS)
|
||||
return until if now < until else None
|
||||
|
||||
def wants_start(self, now: datetime) -> bool:
|
||||
"""Would this pack begin a cycle on this tick if the site let it?
|
||||
|
||||
@@ -331,8 +451,10 @@ class Maintenance:
|
||||
about who was asking - so the IDLE branch of `tick()` calls this one.
|
||||
"""
|
||||
return (self.phase == IDLE and self.cfg.enabled
|
||||
and now.hour == self.cfg.start_hour and self.due(now)
|
||||
and self._cooled(now))
|
||||
and in_start_slot(now, self.cfg.start_hour, self.tz)
|
||||
and self.due(now)
|
||||
and self._cooled(now)
|
||||
and self.backoff_until(now) is None)
|
||||
|
||||
# -- operations ----------------------------------------------------------
|
||||
def force_start(self, now: datetime, blocked_by: str = "") -> list:
|
||||
@@ -360,6 +482,140 @@ class Maintenance:
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
return events
|
||||
|
||||
def _charge_account(self, now: datetime, soc: float | None,
|
||||
gate_open: bool) -> dict:
|
||||
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
|
||||
|
||||
`open_min` counts only ticks with the price gate open; `flat_min` counts
|
||||
gate-open minutes since the SoC last beat its best; a closed gate pauses
|
||||
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
|
||||
counts for nothing. A state file from before MAINT-13, or from another
|
||||
charge, starts from the wall-clock minutes so far: the old behaviour.
|
||||
|
||||
MAINT-14: `soc` may be None (no reading). Time still counts, the stall
|
||||
wait pauses, and `last` keeps the last SoC seen (saved with the rest).
|
||||
"""
|
||||
since = self.store.get("phase_started")
|
||||
trk = self._trk
|
||||
if trk is None:
|
||||
raw = self.store.get("charge_track")
|
||||
if isinstance(raw, dict) and raw.get("since") == since:
|
||||
trk = dict(raw)
|
||||
else:
|
||||
trk = {"since": since, "open_min": self._elapsed_min(now),
|
||||
"flat_min": 0.0,
|
||||
"best": None if soc is None else float(soc),
|
||||
"last": None if soc is None else float(soc), "at": None}
|
||||
self._trk = trk
|
||||
at = trk.get("at")
|
||||
try:
|
||||
last = datetime.fromisoformat(at) if at else None
|
||||
except (TypeError, ValueError):
|
||||
last = None
|
||||
dt = 0.0 if last is None else min(
|
||||
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
|
||||
trk["at"] = now.isoformat()
|
||||
if soc is None:
|
||||
pass
|
||||
elif trk.get("best") is None or soc > trk["best"]:
|
||||
trk["best"], trk["flat_min"] = float(soc), 0.0
|
||||
elif gate_open:
|
||||
trk["flat_min"] += dt
|
||||
if soc is not None:
|
||||
trk["last"] = float(soc)
|
||||
if gate_open:
|
||||
trk["open_min"] += dt
|
||||
saved = self._trk_saved
|
||||
if saved is None or (now - saved).total_seconds() >= CHARGE_SAVE_MIN * 60:
|
||||
self.store.set("charge_track", dict(trk))
|
||||
self._trk_saved = now
|
||||
return trk
|
||||
|
||||
def _fail(self, now: datetime, kind: str, why: str) -> MaintResult:
|
||||
"""MAINT-13: stand down, remember the failure, and tell the Controller."""
|
||||
events = self.abort(now, why)
|
||||
self.store.set_time("last_failed", now)
|
||||
msg = (f"maintenance: the cycle did not finish. It waits "
|
||||
f"{FAIL_BACKOFF_DAYS} days before it tries again.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _hold(self, now: datetime, events: list) -> MaintResult:
|
||||
"""HOLD for one tick, with or without a SoC reading (MAINT-15).
|
||||
|
||||
HOLD needs no level to end: it is reached only after the charge counted
|
||||
as done (MAINT-13/14), so its end is a time check and nothing else.
|
||||
"""
|
||||
elapsed = self._elapsed_min(now)
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD stays at 0 W and ends at its normal time (MAINT-15). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
Nothing here may start a phase change that needs the level.
|
||||
"""
|
||||
if self._nosoc_since is None:
|
||||
self._nosoc_since = now
|
||||
self._nosoc_said = False
|
||||
self._trk_saved = None # save the last SoC seen, now
|
||||
if phase == DRAIN:
|
||||
msg = ("maintenance: the battery level is unknown, so the "
|
||||
"drain holds at 0 W until it is back.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
tail = ("The hold still ends at its normal time."
|
||||
if phase == HOLD else
|
||||
f"The time limit of the {phase} still applies.")
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
f"{tail}")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return self._hold(now, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
return self._fail(now, "drain",
|
||||
f"drain stuck, battery level unknown, after "
|
||||
f"{elapsed / 60:.0f} h")
|
||||
return MaintResult(DRAIN, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, None, gate_open)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
last = trk.get("last")
|
||||
if last is not None and last >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up and the last level "
|
||||
f"seen was {last:.0f} %, close enough to full, so the "
|
||||
f"charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if elapsed > CHARGE_WALL_TIMEOUT_MIN:
|
||||
lim = f"the {CHARGE_WALL_TIMEOUT_MIN // 1440}-day limit"
|
||||
else:
|
||||
lim = f"{trk['open_min'] / 60:.0f} h of charging time"
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck, battery level unknown, after {lim}")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
def abort(self, now: datetime, why: str) -> list:
|
||||
events = []
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
@@ -387,13 +643,16 @@ class Maintenance:
|
||||
|
||||
# -- the machine ---------------------------------------------------------
|
||||
def tick(self, now: datetime, soc: float | None,
|
||||
blocked_by: str = "") -> MaintResult:
|
||||
blocked_by: str = "", gate_open: bool = True) -> MaintResult:
|
||||
"""One cycle of this pack's state machine.
|
||||
|
||||
`blocked_by` is `arbitrate()`'s answer for THIS pack: empty when the
|
||||
site's one maintenance slot is available to it, otherwise the reason it
|
||||
is not. It gates two things and nothing else - a start, and a phase that
|
||||
is already moving power on a pack that does not hold the slot.
|
||||
|
||||
`gate_open` (MAINT-13) is whether the pack may charge now (the price
|
||||
gate); only those minutes count towards the charge timeout.
|
||||
"""
|
||||
events: list = []
|
||||
phase = self.phase
|
||||
@@ -444,13 +703,13 @@ class Maintenance:
|
||||
# transitions below mean anything, and a stale "100 %" would end the
|
||||
# charge phase having charged nothing. Hold the current phase's command
|
||||
# and wait; the phase timeout is the backstop.
|
||||
#
|
||||
# MAINT-14: "hold and wait" is not "wait for ever". The timeouts run
|
||||
# here too, and a drain holds at 0 W (an unknown level never allows
|
||||
# discharge, TEL-08). See `_no_soc`.
|
||||
if soc is None:
|
||||
_LOG.warning("maintenance: no SoC reading, holding phase %s", phase)
|
||||
if phase == DRAIN:
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
return self._no_soc(now, phase, gate_open, events)
|
||||
self._nosoc_since = None
|
||||
|
||||
elapsed = self._elapsed_min(now)
|
||||
|
||||
@@ -461,8 +720,8 @@ class Maintenance:
|
||||
f"after {elapsed:.0f} min -> charge")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
events += self.abort(now, f"drain stuck at {soc:.0f} % after {elapsed:.0f} min")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
return self._fail(now, "drain", f"drain stuck at {soc:.0f} % "
|
||||
f"after {elapsed:.0f} min")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
|
||||
if phase == CHARGE:
|
||||
@@ -471,22 +730,31 @@ class Maintenance:
|
||||
f"maintenance: charge complete at {soc:.0f} % after "
|
||||
f"{elapsed:.0f} min -> holding {self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if elapsed > CHARGE_TIMEOUT_MIN:
|
||||
events += self.abort(now, f"charge stuck at {soc:.0f} % after {elapsed:.0f} min")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, soc, gate_open)
|
||||
near = soc >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT
|
||||
# MAINT-13 rule 1: close to full and no longer taking charge.
|
||||
if near and trk["flat_min"] >= CHARGE_STALL_MIN:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: the battery takes no more charge at "
|
||||
f"{soc:.0f} %, so the charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
# MAINT-13 rule 2: out of time close to full is complete.
|
||||
if near:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up at {soc:.0f} %, "
|
||||
f"close enough to full, so the charge counts as "
|
||||
f"done -> holding {self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck at {soc:.0f} % after "
|
||||
f"{trk['open_min']:.0f} min of charging time")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
if phase == HOLD:
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
|
||||
@@ -102,6 +102,7 @@ class Notice:
|
||||
title: str
|
||||
body: str
|
||||
section: str = "" # the DOCS.md heading, when it is not the title itself
|
||||
body_nl: str = "" # MAINT-13: the same words in Dutch, shown under the English
|
||||
|
||||
@property
|
||||
def docs(self) -> str:
|
||||
@@ -110,7 +111,9 @@ class Notice:
|
||||
def data(self) -> dict:
|
||||
"""The `persistent_notification.create` payload."""
|
||||
return {"notification_id": self.id, "title": self.title,
|
||||
"message": f"{self.body}\n\n{details(self.docs)}"}
|
||||
"message": f"{self.body}\n\n"
|
||||
+ (f"{self.body_nl}\n\n" if self.body_nl else "")
|
||||
+ details(self.docs)}
|
||||
|
||||
|
||||
# --- the catalogue ----------------------------------------------------------
|
||||
@@ -124,6 +127,8 @@ T_CIRCULATING = "Inverters working against each other"
|
||||
T_NOT_DELIVERING = "{unit} is not delivering"
|
||||
S_NOT_DELIVERING = "An inverter is not delivering"
|
||||
T_METER_FROZEN = "Meter reading may be stuck"
|
||||
T_MAINT_FAILED = "Battery cycle did not finish"
|
||||
T_MAINT_FAILED_NL = "Batterijcyclus niet afgerond"
|
||||
|
||||
ID_LOOP_BOUND = "goodwe_integrator_bound"
|
||||
ID_OUTPUT_CLAMP = "goodwe_output_clamp"
|
||||
@@ -132,6 +137,7 @@ ID_PEAK_RESERVE = "goodwe_peak_soc_floor"
|
||||
ID_CIRCULATING = "goodwe_circulating_power"
|
||||
ID_NOT_DELIVERING = "goodwe_not_delivering_{slug}"
|
||||
ID_METER_FROZEN = "goodwe_meter_frozen"
|
||||
ID_MAINT_FAILED = "goodwe_maint_failed_{slug}"
|
||||
|
||||
# Which limit cut a command (clamp.ClampResult.bound, plus the loop's own).
|
||||
# The setting is named by its label, "Inverter rating (W)".
|
||||
@@ -217,7 +223,7 @@ def peak_saturated(ceiling_w, *, shadow: bool = False) -> Notice:
|
||||
|
||||
|
||||
def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> Notice:
|
||||
packs=(), others: bool = False) -> Notice:
|
||||
"""SAFETY-24/25/32: the peak guard may not draw the battery any lower.
|
||||
|
||||
The last sentence is SAFETY-25 and must stay: the reserve binds the peak
|
||||
@@ -227,7 +233,8 @@ def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
roster means some inverter's cut-out level is missing (the peak reserve
|
||||
itself always has a value) - so the action names the cut-out level.
|
||||
Both are named by their setting labels, "Peak reserve (%)" and "Battery
|
||||
cut-out level (%)".
|
||||
cut-out level (%)". `others`: the other batteries give all they can and
|
||||
it is not enough (SAFETY-87), so the limit MAY be passed.
|
||||
"""
|
||||
if soc_unread:
|
||||
why = "The battery level cannot be read"
|
||||
@@ -241,6 +248,12 @@ def peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
why = (f"The battery of {names(packs)} is at its peak reserve" if packs
|
||||
else "The battery is at its peak reserve")
|
||||
act = "Switch off large loads, or lower the peak reserve."
|
||||
if others:
|
||||
return Notice(ID_PEAK_RESERVE, ALARM, T_PEAK_RESERVE,
|
||||
f"{why}, and the other batteries cannot keep this "
|
||||
f"15-minute period under your {watts(ceiling_w)} peak "
|
||||
f"limit alone. {act} Home use can still draw a battery "
|
||||
f"below its reserve, down to its cut-out level.")
|
||||
return Notice(ID_PEAK_RESERVE, ALARM, T_PEAK_RESERVE,
|
||||
f"{why}, so this 15-minute period will go over your "
|
||||
f"{watts(ceiling_w)} peak limit and raise this month's peak. "
|
||||
@@ -288,6 +301,24 @@ def meter_frozen(unchanged_s) -> Notice:
|
||||
f"stop control on the add-on page.")
|
||||
|
||||
|
||||
def maint_failed(kind: str, days: int, unit: str = "", slug: str = "") -> Notice:
|
||||
"""MAINT-13: a monthly cycle stopped before it was done. Said once."""
|
||||
full = kind == "charge"
|
||||
who = unit or "The battery"
|
||||
who_nl = unit or "De batterij"
|
||||
en = f"{who} did not {'fill up' if full else 'empty'}, so its cycle " \
|
||||
f"stopped and tries again in {days} days."
|
||||
nl = f"{who_nl} raakte niet {'vol' if full else 'leeg'}, dus de cyclus is " \
|
||||
f"gestopt en probeert het over {days} dagen opnieuw."
|
||||
return Notice(ID_MAINT_FAILED.format(slug=slug or "battery"), WARNING,
|
||||
T_MAINT_FAILED, en, body_nl=f"{T_MAINT_FAILED_NL}. {nl}")
|
||||
|
||||
|
||||
def row_maint_waits(until_text: str) -> str:
|
||||
"""MAINT-13: the status row while a failed cycle waits."""
|
||||
return f"Waits until {until_text} after a cycle that did not finish."
|
||||
|
||||
|
||||
# --- the status page (UX-08 phase 2b) ----------------------------------------
|
||||
# The rows of the Commissioning list and the banner at the top of the add-on
|
||||
# page. `main.py` decides WHEN a row shows and its colour (ok / warn / bad);
|
||||
@@ -405,6 +436,17 @@ def banner_shadow(latched: bool) -> str:
|
||||
return "Shadow mode: the battery is not controlled. Inverters stay at 0 W."
|
||||
|
||||
|
||||
def banner_ha_waiting() -> str:
|
||||
"""SAFETY-112: the Supervisor passes nothing on until Home Assistant has
|
||||
finished starting, so the add-on can neither read nor write."""
|
||||
return "Waiting for Home Assistant to finish starting"
|
||||
|
||||
|
||||
def row_ha_waiting() -> str:
|
||||
return ("Home Assistant is not answering, perhaps it is still starting. "
|
||||
"Control resumes by itself when it answers.")
|
||||
|
||||
|
||||
# Rows: control and the meter. "Control" is what the add-on does, as in
|
||||
# "start control" (STYLE.md section 4).
|
||||
def row_controller_starting() -> str:
|
||||
@@ -470,8 +512,9 @@ def row_peak_saturated(ceiling_w) -> str:
|
||||
|
||||
|
||||
def row_peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
packs=()) -> str:
|
||||
"""SAFETY-24/25/32. The second sentence is SAFETY-25 and must stay."""
|
||||
packs=(), others: bool = False) -> str:
|
||||
"""SAFETY-24/25/32. The last sentence is SAFETY-25 and must stay.
|
||||
`others`: as in `peak_reserve()` (SAFETY-87)."""
|
||||
if soc_unread:
|
||||
why = "Battery level cannot be read"
|
||||
elif floor_unknown:
|
||||
@@ -479,6 +522,10 @@ def row_peak_reserve(ceiling_w, *, soc_unread: bool, floor_unknown: bool,
|
||||
else:
|
||||
why = (f"{names(packs)} battery at its peak reserve" if packs
|
||||
else "Battery at its peak reserve")
|
||||
if others:
|
||||
return (f"{why}. The others cannot hold the {watts(ceiling_w)} peak "
|
||||
f"limit alone. Home use still draws it lower, to the cut-out "
|
||||
f"level.")
|
||||
return (f"{why}, so the {watts(ceiling_w)} peak limit will be passed. Home "
|
||||
f"use still draws the battery below it, down to the cut-out level.")
|
||||
|
||||
@@ -718,6 +765,15 @@ def row_pv_partial(missing, count) -> str:
|
||||
f"reading")
|
||||
|
||||
|
||||
def row_forecast_gap(day, missing, count) -> str:
|
||||
"""OPT-17. `day` is "today" or "tomorrow"; `missing` are the 1-based
|
||||
positions of the forecast entities with no usable reading."""
|
||||
which = names([str(n) for n in missing])
|
||||
many = len(missing) > 1
|
||||
return (f"Solar forecast for {day}: not used, source{'s' if many else ''} "
|
||||
f"{which} of {count} {'have' if many else 'has'} no reading")
|
||||
|
||||
|
||||
def row_pv_single_ignored() -> str:
|
||||
return f"Solar production: clear {PV_ONE}, the per-inverter list replaces it"
|
||||
|
||||
@@ -781,6 +837,12 @@ def row_peak_guard_blind(why: str) -> str:
|
||||
f"meanwhile")
|
||||
|
||||
|
||||
def row_peak_guard_unmeasured() -> str:
|
||||
"""SAFETY-90. Before the first reading; that part counts as high use."""
|
||||
return ("Peak guard: part of this 15-minute period was not measured, "
|
||||
"counted as high use")
|
||||
|
||||
|
||||
def row_peak_guard_on(floor_w, limit_w, *, shadow: bool = False) -> str:
|
||||
if shadow:
|
||||
return (f"Peak guard: would ask for {watts(floor_w)} to stay under "
|
||||
@@ -835,6 +897,8 @@ WHY_LIMIT = {
|
||||
"pack": "the battery level",
|
||||
"reserve": "the battery reserve",
|
||||
"maintenance": "battery maintenance",
|
||||
"charge": "battery maintenance",
|
||||
"hold": "battery maintenance",
|
||||
"refused": "a battery that refuses power",
|
||||
}
|
||||
|
||||
@@ -898,6 +962,7 @@ HINTS = {
|
||||
"peak_on": "Peak guard started",
|
||||
"peak_off": "Peak guard idle",
|
||||
"peak_blind": "Peak guard cannot read the meter well",
|
||||
"peak_gap": "Meter is back, the peak guard counts the missed time as high use",
|
||||
"peak_saturated": T_PEAK_SATURATED,
|
||||
"peak_reserve": T_PEAK_RESERVE,
|
||||
"meter_frozen": T_METER_FROZEN,
|
||||
@@ -906,6 +971,9 @@ HINTS = {
|
||||
"trade_charge": "Trading: charging while the price is low",
|
||||
"trade_give": "Trading: giving power while the price is high",
|
||||
"trade_off": "Trading: waiting for a better price",
|
||||
"forecast_read": "Solar forecast read, the day plan uses it",
|
||||
"forecast_none": "No solar forecast, so Leftover solar takes solar only",
|
||||
"forecast_no_tomorrow": "Tomorrow's solar forecast is not used, a source has no reading",
|
||||
"split": "The power split between inverters changed",
|
||||
"clash": "Two limits clash, inverters set to 0 W",
|
||||
"no_setpoint": "An inverter has no “Setpoint entity”, inverters stay at 0 W",
|
||||
@@ -924,11 +992,13 @@ HINTS = {
|
||||
"not_delivering_cleared": "{unit}: not-delivering alarm cleared",
|
||||
"maintenance": "Battery maintenance: {phase}",
|
||||
"maint_paused": "Maintenance charging paused to stay under the peak limit",
|
||||
"maint_failed": "The battery cycle did not finish, so it waits before trying again",
|
||||
"pack_on": "{unit}: battery switched on",
|
||||
"pack_off": "{unit}: battery switched off, it is asked for 0 W",
|
||||
"pack_mode": "{unit}: battery mode changed",
|
||||
"pack_sell": "{unit}: selling switched",
|
||||
"maint_off": "{unit}: maintenance stopped, the battery is switched off",
|
||||
"maint_waits": "{unit} cannot give power now, so its monthly cycle waits",
|
||||
"mode_fault": "{unit}: battery mode ignored because of a software fault",
|
||||
}
|
||||
|
||||
@@ -996,6 +1066,10 @@ def status_samples() -> list:
|
||||
("banner_setup_only", None, banner_setup_only()),
|
||||
("row_setup_only", AMBER, row_setup_only()),
|
||||
("banner_shadow", None, banner_shadow(True)),
|
||||
("banner_not_ready", None, banner_not_ready(
|
||||
{"text": row_ha_waiting(), "banner": banner_ha_waiting()})),
|
||||
("banner_ha_waiting", None, banner_ha_waiting()),
|
||||
("row_ha_waiting", RED, row_ha_waiting()),
|
||||
("row_controller_starting", GREEN, row_controller_starting()),
|
||||
("row_controller_ran", GREEN, row_controller_ran(2)),
|
||||
("row_controller_stalled", RED, row_controller_stalled(45, 30)),
|
||||
@@ -1009,6 +1083,9 @@ def status_samples() -> list:
|
||||
("row_peak_guard_off", AMBER, row_peak_guard_off()),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=False, packs=["inverter-b"])),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=False, floor_unknown=False, packs=["inverter-b"],
|
||||
others=True)),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
5000, soc_unread=True, floor_unknown=False)),
|
||||
("row_peak_reserve", RED, row_peak_reserve(
|
||||
@@ -1062,6 +1139,8 @@ def status_samples() -> list:
|
||||
"entity - it cannot be read in watts")),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2, 3], 3)),
|
||||
("row_pv_partial", AMBER, row_pv_partial([2], 2)),
|
||||
("row_forecast_gap", AMBER, row_forecast_gap("today", [2], 3)),
|
||||
("row_forecast_gap", AMBER, row_forecast_gap("tomorrow", [1, 2], 2)),
|
||||
("row_pv_single_ignored", AMBER, row_pv_single_ignored()),
|
||||
("row_pv_negative", AMBER, row_pv_negative(2, 3, -1500, False)),
|
||||
("row_pv_negative", AMBER, row_pv_negative(1, 1, -1500, True)),
|
||||
@@ -1077,6 +1156,7 @@ def status_samples() -> list:
|
||||
("row_peak_guard_idle", GREEN, row_peak_guard_idle(1300, 2500, True)),
|
||||
("row_peak_guard_idle", GREEN, row_peak_guard_idle(1300, 2500, False)),
|
||||
("row_peak_guard_quiet", GREEN, row_peak_guard_quiet()),
|
||||
("row_peak_guard_unmeasured", AMBER, row_peak_guard_unmeasured()),
|
||||
*(("row_peak_guard_blind", AMBER, row_peak_guard_blind(k))
|
||||
for k in BLIND_WORDS),
|
||||
("row_peak_guard_on", AMBER, row_peak_guard_on(1200, 2500)),
|
||||
@@ -1090,6 +1170,7 @@ def status_samples() -> list:
|
||||
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
|
||||
True)),
|
||||
("row_circulating_check", GREEN, row_circulating_check(0, 0, 60)),
|
||||
("row_maint_waits", AMBER, row_maint_waits("2026-10-13")),
|
||||
]
|
||||
|
||||
|
||||
@@ -1111,6 +1192,8 @@ def samples() -> list:
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False,
|
||||
packs=["inverter-b"]),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=False,
|
||||
packs=["inverter-b"], others=True),
|
||||
peak_reserve(5000, soc_unread=True, floor_unknown=False),
|
||||
peak_reserve(5000, soc_unread=False, floor_unknown=True),
|
||||
circulating(["inverter-a"], ["inverter-b"]),
|
||||
@@ -1118,6 +1201,8 @@ def samples() -> list:
|
||||
not_delivering("inverter-b", "inverter_b"),
|
||||
meter_frozen(600),
|
||||
meter_frozen(90),
|
||||
maint_failed("charge", 7),
|
||||
maint_failed("drain", 7, "inverter-b", "inverter_b"),
|
||||
]
|
||||
|
||||
|
||||
@@ -1172,6 +1257,11 @@ LABELS = {
|
||||
"batt_entity": "Battery power entity",
|
||||
"pv_entity": "Solar production entity",
|
||||
"pv_entities": "Solar production entities, per inverter",
|
||||
"pv_forecast_entity": "Solar forecast, today",
|
||||
"pv_forecast_tomorrow_entity": "Solar forecast, tomorrow",
|
||||
"pv_forecast_entities": "Several solar forecasts, today",
|
||||
"pv_forecast_tomorrow_entities": "Several solar forecasts, tomorrow",
|
||||
"solar_trust_pct": "Trust in the forecast",
|
||||
"p1_phase_import_entities": "Import entities per phase",
|
||||
"p1_phase_export_entities": "Export entities per phase",
|
||||
}
|
||||
|
||||
@@ -23,7 +23,11 @@ Roles (the page's Why line names them):
|
||||
|
||||
Rules that keep this safe (tests: test_modes_p3.py, test_price_run_fixes.py):
|
||||
* every range holds 0 W (a mode may forbid a direction, never force one);
|
||||
* a Solar first battery never charges from the grid (no forecast yet, P4);
|
||||
* a Solar first battery never charges from the grid;
|
||||
* P4: with a day plan (`targets`), a Leftover solar battery charges from
|
||||
the grid only up to its planned level, never above the ceiling; with
|
||||
none it takes solar only (P3 option A). Cheap hours only fills to the
|
||||
ceiling either way (`charge_to()`);
|
||||
* grid charging needs a measured peak guard that is clear and a measured
|
||||
headroom (SAFETY-45); the trade is sized to that headroom, whose aim is
|
||||
`peak_cap_w - peak_margin_w` (SAFETY-79). It starts only at START_W or
|
||||
@@ -42,13 +46,15 @@ Rules that keep this safe (tests: test_modes_p3.py, test_price_run_fixes.py):
|
||||
run in that direction: the refusal wins over the run. The one exception
|
||||
is its SAFETY-73 probe inside a cheap run (OPT-15): it is a charger then,
|
||||
pinned at PROBE_W by its own claim, so the others rest (one sign) and the
|
||||
card's "tries again every 15 minutes" holds in the run too.
|
||||
card's "tries again every 15 minutes" holds in the run too;
|
||||
* no grid charge while another battery drains for its monthly cycle
|
||||
(`draining`, SAFETY-78): it would charge against the drain.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
|
||||
from .packmode import (CHEAP_HOURS, GRID_CHARGE_MODES, LEFTOVER_SOLAR,
|
||||
SOLAR_FIRST)
|
||||
PLAN_CHARGE_MODES, SOLAR_FIRST)
|
||||
|
||||
OFF, HOUSE, HOLD, GIVE, SELL, CHARGE, REST = (
|
||||
"off", "house", "hold", "give", "sell", "charge", "rest")
|
||||
@@ -92,16 +98,38 @@ def _room_kwh(p: Pack, pct: float) -> float:
|
||||
return max(0.0, abs(pct - p.soc)) / 100.0 * float(p.capacity_kwh)
|
||||
|
||||
|
||||
def chargers(packs, ceiling_pct, done=(), probe=False) -> list:
|
||||
"""Batteries that may charge from the grid in a cheap run: the modes in
|
||||
`packmode.GRID_CHARGE_MODES` (Cheap hours only until P4's forecast).
|
||||
With `probe`, also one refusing to charge while its SAFETY-73 probe is
|
||||
open: its own P_SAFETY pin keeps it at PROBE_W (OPT-15)."""
|
||||
return [p for p in packs
|
||||
if p.use and p.idle and p.live and p.mode in GRID_CHARGE_MODES
|
||||
and p.soc is not None and p.soc < ceiling_pct
|
||||
and (p.refused >= 0 or (probe and p.probing))
|
||||
and p.name not in done]
|
||||
def charge_to(p: Pack, ceiling_pct, targets=None):
|
||||
"""The level this battery may charge to from the grid, or None.
|
||||
|
||||
`targets` is the day plan (`dayplan.plan()`: name -> level), or None
|
||||
when there is none (no forecast, stale, or not configured). With no plan
|
||||
this is P3 option A exactly: Cheap hours to the ceiling, the others never.
|
||||
With a plan, a Leftover solar battery charges only to its planned level
|
||||
(the sun fills the rest); a battery the plan leaves out, Cheap hours only
|
||||
included, gets the no-plan answer. Solar first never charges."""
|
||||
if p.mode in GRID_CHARGE_MODES:
|
||||
return float(ceiling_pct)
|
||||
if targets is None or p.name not in targets \
|
||||
or p.mode not in PLAN_CHARGE_MODES:
|
||||
return None
|
||||
t = targets[p.name]
|
||||
return None if t is None else min(float(ceiling_pct), float(t))
|
||||
|
||||
|
||||
def chargers(packs, ceiling_pct, done=(), targets=None, probe=False) -> list:
|
||||
"""Batteries that may charge from the grid in a cheap run: below the
|
||||
level `charge_to()` allows them (P4: the day plan's). With `probe`, also
|
||||
one refusing to charge while its SAFETY-73 probe is open: its own P_SAFETY
|
||||
pin keeps it at PROBE_W (OPT-15)."""
|
||||
out = []
|
||||
for p in packs:
|
||||
to = charge_to(p, ceiling_pct, targets)
|
||||
if (to is not None and p.use and p.idle and p.live
|
||||
and p.soc is not None and p.soc < to
|
||||
and (p.refused >= 0 or (probe and p.probing))
|
||||
and p.name not in done):
|
||||
out.append(p)
|
||||
return out
|
||||
|
||||
|
||||
def sellers(packs, floor_pct, done=()) -> list:
|
||||
@@ -113,11 +141,15 @@ def sellers(packs, floor_pct, done=()) -> list:
|
||||
and p.refused <= 0 and p.name not in done]
|
||||
|
||||
|
||||
def energy(packs, floor_pct, ceiling_pct, done_charge=(), done_sell=()):
|
||||
"""`(charge_kwh, charge_kw, sell_kwh, sell_kw)` for `priceruns.plan()`."""
|
||||
ch = chargers(packs, ceiling_pct, done_charge)
|
||||
def energy(packs, floor_pct, ceiling_pct, done_charge=(), done_sell=(),
|
||||
targets=None):
|
||||
"""`(charge_kwh, charge_kw, sell_kwh, sell_kw)` for `priceruns.plan()`.
|
||||
With a day plan the charge is each battery's shortfall, so the cheap run
|
||||
is only as long as the shortfall needs."""
|
||||
ch = chargers(packs, ceiling_pct, done_charge, targets)
|
||||
se = sellers(packs, floor_pct, done_sell)
|
||||
return (sum(_room_kwh(p, ceiling_pct) for p in ch),
|
||||
return (sum(_room_kwh(p, charge_to(p, ceiling_pct, targets))
|
||||
for p in ch),
|
||||
sum(abs(p.rating_w) for p in ch) / 1000.0,
|
||||
sum(_room_kwh(p, floor_pct) for p in se),
|
||||
sum(abs(p.rating_w) for p in se) / 1000.0)
|
||||
@@ -125,7 +157,8 @@ def energy(packs, floor_pct, ceiling_pct, done_charge=(), done_sell=()):
|
||||
|
||||
def decide(runs, now, packs, *, charge_ok, sell_ok, trade_why, price_now,
|
||||
headroom_w, floor_pct, ceiling_pct, house_w, charging_now=False,
|
||||
blocked=False, done_charge=(), done_sell=()) -> Tick:
|
||||
blocked=False, done_charge=(), done_sell=(),
|
||||
targets=None, draining=False) -> Tick:
|
||||
"""This tick's ranges, roles and site ask.
|
||||
|
||||
`runs` is the kept `priceruns.RunPlan` or None (no fresh prices).
|
||||
@@ -136,7 +169,9 @@ def decide(runs, now, packs, *, charge_ok, sell_ok, trade_why, price_now,
|
||||
`house_w` is the measured house (grid + batteries), or None.
|
||||
`charging_now` says last tick charged (then any headroom above 0 keeps
|
||||
it going); `blocked` that the guard or the headroom stopped a charge in
|
||||
this 15-minute period.
|
||||
this 15-minute period. `targets` is the day plan (`charge_to()`).
|
||||
`draining` says a battery drains for its monthly cycle, so none may
|
||||
charge from the grid (why "cycle").
|
||||
"""
|
||||
plan_on = runs is not None and runs.on
|
||||
in_cheap = plan_on and runs.cheap.holds(now) and runs.charge_useful()
|
||||
@@ -144,8 +179,10 @@ def decide(runs, now, packs, *, charge_ok, sell_ok, trade_why, price_now,
|
||||
in_sell = plan_on and runs.sell is not None and runs.sell.holds(now)
|
||||
|
||||
why = None
|
||||
ch = chargers(packs, ceiling_pct, done_charge, probe=True) \
|
||||
ch = chargers(packs, ceiling_pct, done_charge, targets, probe=True) \
|
||||
if in_cheap else []
|
||||
if ch and draining:
|
||||
ch, why = [], "cycle"
|
||||
charging = False
|
||||
if ch:
|
||||
need = 0.0 if charging_now else START_W
|
||||
|
||||
@@ -318,6 +318,13 @@ class QuarterAverager:
|
||||
with `roll=True` credits it into the next block as `add()` will."""
|
||||
return self._last_t
|
||||
|
||||
@property
|
||||
def held_since(self) -> datetime | None:
|
||||
"""SAFETY-90: when the held sample arrived (its `ingest_ts`), or None."""
|
||||
if self._last_t is None:
|
||||
return None
|
||||
return datetime.fromtimestamp(self._last_t, timezone.utc)
|
||||
|
||||
@property
|
||||
def offtake_avg_w(self) -> float:
|
||||
"""Average offtake over the part of the open block seen so far."""
|
||||
|
||||
@@ -46,10 +46,13 @@ SELL_KEY = "pack_sell" # OPT-11 P3: sell in the sell run
|
||||
# refused; the sell code in modetrade/priceruns stays, unreachable.
|
||||
SELLING_ENABLED = False
|
||||
|
||||
# The modes that may charge from the grid in a cheap run. Leftover solar joins
|
||||
# when the solar forecast exists (P4); until then it takes solar only (owner
|
||||
# decision 2026-09-29, option A).
|
||||
# The modes that may charge from the grid in a cheap run with no day plan.
|
||||
# Leftover solar takes solar only then (owner decision 2026-09-29, option A).
|
||||
GRID_CHARGE_MODES = (CHEAP_HOURS,)
|
||||
# OPT-11 P4: with a fresh solar forecast, the day plan (dayplan.py) lets
|
||||
# Leftover solar charge from the grid, by the shortfall only. Cheap hours only
|
||||
# ignores the plan (fills to the ceiling); Solar first never grid-charges.
|
||||
PLAN_CHARGE_MODES = (LEFTOVER_SOLAR,)
|
||||
|
||||
|
||||
def enabled(opts) -> bool:
|
||||
|
||||
@@ -183,6 +183,8 @@ guard passes its own tests while being switched off:
|
||||
record). Those seconds make the projection read LOW, which is the
|
||||
under-guarding direction. The threshold is `max_hold_s` itself - the point
|
||||
p1.py already stops trusting a held sample - not a new number.
|
||||
SAFETY-90: once readings are back, main.py counts those seconds
|
||||
(`fill_gaps()`), so this holds only while the gap lasts.
|
||||
|
||||
* FROZEN. SAFETY-18's conjunction, evaluated through `freeze.looks_frozen()`
|
||||
rather than re-written here. A frozen meter is the worst case of all: the
|
||||
@@ -397,7 +399,7 @@ function, so whichever way the owner answers, this file does not change and does
|
||||
not need re-testing. Nothing here indexes a phase.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from dataclasses import dataclass, replace
|
||||
|
||||
from . import messages
|
||||
from .arbiter import ACTUATOR_SITE, P_PEAK, Claim
|
||||
@@ -490,11 +492,18 @@ class PeakDecision:
|
||||
# floor refused to size it. Mutually exclusive with `saturated` by
|
||||
# construction: this branch asks for nothing, so it cannot have run out of
|
||||
# inverter. `soc_floor_reason` says WHICH of the two ways it bound.
|
||||
# SAFETY-87: at N>=2 it may ask the batteries above their reserve for
|
||||
# `able_w`, all they have, when that is not enough (`place_on_able()`).
|
||||
floor_limited: bool = False
|
||||
soc: float | None = None
|
||||
soc_floor: float | None = None
|
||||
soc_floor_reason: str | None = None
|
||||
reason: str = ""
|
||||
# SAFETY-87, N>=2 only: the batteries at or under their own reserve,
|
||||
# which give nothing for the peak, and what the others can give (None
|
||||
# when they are not asked). See `place_on_able()`.
|
||||
held: tuple = ()
|
||||
able_w: float | None = None
|
||||
|
||||
def explain(self) -> str:
|
||||
"""Idle: the status row's plain words (UX-08). Engaged: `reason`, the
|
||||
@@ -592,6 +601,57 @@ def blindness(projection, max_hold_s, frozen: bool) -> str | None:
|
||||
return None
|
||||
|
||||
|
||||
# SAFETY-90. Seconds of uncounted time below which nothing is filled: float
|
||||
# noise between the averager's sums and the wall clock, never a real gap.
|
||||
GAP_TOL_S = 1e-3
|
||||
|
||||
|
||||
def gap_w(ceiling_w, *seen_w) -> float:
|
||||
"""SAFETY-90: the watts a meter gap is counted at. The highest of the
|
||||
limit and `seen_w`, the import with the batteries at 0 W (grid + their
|
||||
discharge) just before and just after the gap; None entries are skipped.
|
||||
DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
|
||||
return max([float(ceiling_w)] + [float(w) for w in seen_w if w is not None])
|
||||
|
||||
|
||||
def fill_gaps(projection, *, tail_s, max_hold_s, unseen_s, gap_w, unseen_w,
|
||||
held_ws=0.0):
|
||||
"""SAFETY-90: `projection` with the seconds the averager did not count
|
||||
(a meter gap past `max_hold_s`) counted at `gap_w`, and those from before
|
||||
this run's first reading (`unseen_s`) at `unseen_w`. `held_ws` is added
|
||||
too: what the gap's first `max_hold_s`, credited at the reading before
|
||||
it, lacks to reach `gap_w`. Returns
|
||||
`(projection, gap seconds filled, unseen seconds filled)`.
|
||||
|
||||
`tail_s` is the age of the held reading: up to `max_hold_s` of it is left
|
||||
as before (the averager credits it once the next reading lands). Past
|
||||
that the gap is still open, nothing is filled and `blindness()` answers
|
||||
as before. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
|
||||
if projection.block_start is None or max_hold_s is None:
|
||||
return projection, 0.0, 0.0
|
||||
wall = float(projection.elapsed_s)
|
||||
tail = min(max(0.0, float(tail_s)), wall)
|
||||
if tail > float(max_hold_s):
|
||||
return projection, 0.0, 0.0
|
||||
covered = wall - uncovered_s(projection)
|
||||
missing = wall - covered - tail
|
||||
if missing <= GAP_TOL_S:
|
||||
missing = 0.0
|
||||
if held_ws <= 0.0:
|
||||
return projection, 0.0, 0.0
|
||||
unseen = min(missing, max(0.0, float(unseen_s)))
|
||||
gap = missing - unseen
|
||||
add_ws = gap * float(gap_w) + unseen * float(unseen_w) + float(held_ws)
|
||||
done = covered + missing
|
||||
return (replace(
|
||||
projection,
|
||||
projected_w=float(projection.projected_w) + add_ws / QUARTER_S,
|
||||
elapsed_w=((float(projection.elapsed_w) * covered + add_ws) / done
|
||||
if done > 0.0 else float(projection.elapsed_w)),
|
||||
covered_frac=(done / wall if wall > 0.0
|
||||
else float(projection.covered_frac))), gap, unseen)
|
||||
|
||||
|
||||
def discharge_permitted(soc, soc_floor) -> str | None:
|
||||
"""SAFETY-24. May the guard size a forced discharge, or why may it not?
|
||||
|
||||
@@ -733,6 +793,43 @@ def binding_soc_floor(packs, soc_floor):
|
||||
return max(floors)
|
||||
|
||||
|
||||
def reserve_split(packs, soc_floor) -> tuple[list, tuple]:
|
||||
"""SAFETY-87: `(packs the guard may spend, names of those it may not)`,
|
||||
each pack graded on its own floor by `pack_permissions()`."""
|
||||
perms = pack_permissions(packs, soc_floor)
|
||||
return ([p for p, (_n, why) in zip(packs, perms) if why is None],
|
||||
tuple(n for n, why in perms if why is not None))
|
||||
|
||||
|
||||
def place_on_able(decision, held, *, able_w, soc, soc_floor) -> PeakDecision:
|
||||
"""SAFETY-87: `decision` with the batteries in `held` (at or under their
|
||||
own reserve) giving nothing for the peak. `able_w`, `soc` and `soc_floor`
|
||||
describe the others, as `decide()`'s arguments do for the roster. A
|
||||
floor-limited decision is re-taken on them: they are asked for the need
|
||||
up to `able_w`, and it stays floor-limited only if that is not enough.
|
||||
`soc` and `soc_floor` keep the roster's verdict, as `decide()` echoed it.
|
||||
DECISIONS/SAFETY-87-guard-uses-able-batteries.md."""
|
||||
held = tuple(held)
|
||||
if not decision.floor_limited or decision.wanted_w is None \
|
||||
or discharge_permitted(soc, soc_floor) is not None:
|
||||
return replace(decision, held=held)
|
||||
wanted = float(decision.wanted_w)
|
||||
floor = min(wanted, float(able_w))
|
||||
head = (f"this 15-minute period heads for {decision.projected_w:.0f} W "
|
||||
f"against a {decision.ceiling_w:.0f} W limit "
|
||||
f"({decision.ceiling_from}), aiming at {decision.target_w:.0f} W. "
|
||||
f"At the peak reserve, so giving nothing for the peak: "
|
||||
f"{messages.names(held)}. The others are asked for {floor:+.0f} W")
|
||||
if floor >= wanted:
|
||||
return replace(decision, floor_limited=False, floor_w=floor,
|
||||
soc_floor_reason=None, held=held, able_w=float(able_w),
|
||||
reason=f"PEAK_GUARD: {head}")
|
||||
return replace(decision, floor_w=floor, held=held, able_w=float(able_w),
|
||||
reason=(f"PEAK_GUARD_FLOOR_LIMITED: {head}, all they can "
|
||||
f"give, but {wanted:+.0f} W was needed, so this "
|
||||
f"period may go over the limit"))
|
||||
|
||||
|
||||
def decide(projection, *, batt_w, cap_w, margin_w, reading, achievable_w, soc,
|
||||
soc_floor, max_hold_s=None, frozen: bool = False) -> PeakDecision:
|
||||
"""The whole guard. Pure: no clock, no I/O, no state carried between calls.
|
||||
@@ -866,6 +963,40 @@ def decide(projection, *, batt_w, cap_w, margin_w, reading, achievable_w, soc,
|
||||
if saturated else "")))
|
||||
|
||||
|
||||
# SAFETY-81. A quarter must end this many W over the real limit before
|
||||
# "Load too high for battery" fires. Above the guard's own landing error at
|
||||
# margin 0 (up to +5.7 W, SAFETY-79 test check 5), which margin 0 accepts.
|
||||
ALARM_MISS_W = 10.0
|
||||
# ...and for this long without a break, so a load that peaks for a few seconds
|
||||
# (a hob or heater cycling) is not read as the rest of the quarter.
|
||||
ALARM_HOLD_S = 10.0
|
||||
|
||||
|
||||
def load_too_high(projection, *, batt_w, ceiling_w, achievable_w) -> bool:
|
||||
"""SAFETY-81. May "Load too high for battery" fire? Only if, with the
|
||||
battery at full power from now on, the quarter still ends more than
|
||||
`ALARM_MISS_W` over the real limit (`ceiling_w`, not the aim).
|
||||
|
||||
This is the miss itself, in W of the quarter average, so it does not have
|
||||
`decide()`'s gain (900 / remaining): near a quarter's end that gain turns
|
||||
a watt over the aim into thousands of W wanted.
|
||||
|
||||
The load is the held meter reading plus `batt_w`. The caller passes the
|
||||
lower of this cycle's and the last cycle's battery reading, so a meter
|
||||
sample taken before the battery's last increase is not counted twice
|
||||
(DECISIONS/SAFETY-81-load-too-high.md). A real overload shows on the meter
|
||||
before the battery moves, so that filter costs it no cycle.
|
||||
"""
|
||||
remaining = QUARTER_S - float(projection.elapsed_s)
|
||||
if batt_w is None or remaining <= 0.0:
|
||||
return False
|
||||
rest = float(projection.held_w) + float(batt_w) - float(achievable_w)
|
||||
done_ws = (QUARTER_S * float(projection.projected_w)
|
||||
- max(float(projection.held_w), 0.0) * remaining)
|
||||
ends_w = (done_ws + max(rest, 0.0) * remaining) / QUARTER_S
|
||||
return ends_w - float(ceiling_w) > ALARM_MISS_W
|
||||
|
||||
|
||||
def charge_headroom_w(decision) -> float | None:
|
||||
"""SAFETY-45. The hardest this SITE may charge without putting the billed
|
||||
quarter over the ceiling, in W, positive - or None when nothing measured it.
|
||||
@@ -1063,5 +1194,6 @@ def claim(decision: PeakDecision) -> Claim | None:
|
||||
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
||||
reason=("blind" if decision.blind
|
||||
else "SoC floor" if decision.floor_limited
|
||||
and not decision.floor_w
|
||||
else "quarter peak"),
|
||||
actuator=ACTUATOR_SITE)
|
||||
|
||||
@@ -0,0 +1,350 @@
|
||||
"""OPT-11 P4: the solar forecast, read from a Home Assistant sensor.
|
||||
|
||||
Pure: HA state dicts and the time in, a `Forecast` (or None and why) out.
|
||||
main.py reads the entities; dayplan.py uses the answer. FCST-01 replaces
|
||||
this later with the add-on's own forecast (owner answer, 2026-09-27).
|
||||
|
||||
Two options name the sensors: `pv_forecast_entity`, the solar energy still
|
||||
to come TODAY, and `pv_forecast_tomorrow_entity`, TOMORROW's (optional; it
|
||||
is only needed for a cheap run before midnight). Supported, by the entities
|
||||
they create (DOCS.md lists them):
|
||||
|
||||
* Forecast.Solar (HA core): `sensor.energy_production_today_remaining` and
|
||||
`sensor.energy_production_tomorrow`. The state only; no hourly split.
|
||||
* Solcast PV Forecast (HACS `solcast_solar`):
|
||||
`sensor.solcast_pv_forecast_forecast_remaining_today` and
|
||||
`..._forecast_tomorrow`, with `detailedForecast` (or `detailedHourly`):
|
||||
`[{period_start, pv_estimate}]`, kW per period.
|
||||
* Open-Meteo Solar Forecast (HACS `open_meteo_solar_forecast`):
|
||||
`sensor.energy_production_today_remaining` / `..._tomorrow`, with
|
||||
`wh_period`: `{period start: Wh}`.
|
||||
|
||||
Any other sensor whose state is energy in Wh, kWh or MWh works too, as a
|
||||
state only. The unit is read, never guessed (the rule `pv.watts()` has).
|
||||
Without an hourly split, the day's energy is spread over a fixed bell from
|
||||
06:00 to 20:00 local time (`BELL_FROM_H`, `BELL_TO_H`).
|
||||
|
||||
A reading older than `FRESH_S`, or from before local midnight, is stale,
|
||||
and a stale or missing forecast is no forecast: the day plan is off and
|
||||
every mode acts as in P3 option A.
|
||||
|
||||
OPT-17: each day may instead name a list (`pv_forecast_entities`,
|
||||
`pv_forecast_tomorrow_entities`), summed by `read_sum()`. One member that is
|
||||
not usable makes that day's sum unusable, never a partial sum.
|
||||
DECISIONS/OPT-17-several-forecast-entities.md.
|
||||
"""
|
||||
|
||||
import math
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from .hass import BAD_STATES
|
||||
from .tariff import BILLING_TZ
|
||||
|
||||
KWH_PER = {"Wh": 0.001, "kWh": 1.0, "MWh": 1000.0}
|
||||
|
||||
# Stale after 3 h. The integrations above refresh at least hourly, so a
|
||||
# 2 h limit would flag a site whose hourly poll was missed once.
|
||||
FRESH_S = 3 * 3600.0
|
||||
|
||||
# The bell a state-only forecast is spread over, in local hours.
|
||||
BELL_FROM_H, BELL_TO_H = 6.0, 20.0
|
||||
|
||||
# Why there is no forecast (the page words are in ui_text `home_words`).
|
||||
NOT_SET, MISSING, UNIT, STALE, BAD = (
|
||||
"not_set", "missing", "unit", "stale", "bad")
|
||||
|
||||
# OPT-17: (single key, list key) per day. A set list replaces the single key;
|
||||
# the validator refuses both set for the same day.
|
||||
TODAY_KEYS = ("pv_forecast_entity", "pv_forecast_entities")
|
||||
TOMORROW_KEYS = ("pv_forecast_tomorrow_entity",
|
||||
"pv_forecast_tomorrow_entities")
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class Day:
|
||||
"""One day's forecast: `kwh` still to come (today) or in all (tomorrow),
|
||||
and the hourly split if the sensor has one: `((start, end, kwh), ...)`."""
|
||||
day0: datetime # local midnight, as UTC
|
||||
kwh: float
|
||||
periods: tuple = ()
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class Forecast:
|
||||
today: Day
|
||||
tomorrow: Day | None
|
||||
at: datetime # when the sensor last reported
|
||||
|
||||
def between(self, t0: datetime, t1: datetime) -> float | None:
|
||||
"""kWh the sun should give between `t0` (now or later) and `t1`.
|
||||
None when the span reaches the sunny hours of a day with no
|
||||
forecast (tomorrow, when its sensor is not set)."""
|
||||
if t1 <= t0:
|
||||
return 0.0
|
||||
last = self.tomorrow or self.today
|
||||
if t1 > last.day0 + timedelta(days=1, hours=BELL_FROM_H):
|
||||
return None
|
||||
total = 0.0
|
||||
for day in (self.today, self.tomorrow):
|
||||
if day is None:
|
||||
continue
|
||||
a = max(t0, day.day0)
|
||||
b = min(t1, day.day0 + timedelta(days=1))
|
||||
if b > a:
|
||||
total += _day_between(day, a, b, t0)
|
||||
return total
|
||||
|
||||
|
||||
def _local_hour(t: datetime) -> float:
|
||||
lt = t.astimezone(BILLING_TZ)
|
||||
return lt.hour + lt.minute / 60.0 + lt.second / 3600.0
|
||||
|
||||
|
||||
def _bell(h: float) -> float:
|
||||
"""Cumulative share of a day's sun by local hour `h` (0..1)."""
|
||||
if h <= BELL_FROM_H:
|
||||
return 0.0
|
||||
if h >= BELL_TO_H:
|
||||
return 1.0
|
||||
x = (h - BELL_FROM_H) / (BELL_TO_H - BELL_FROM_H)
|
||||
return (1.0 - math.cos(math.pi * x)) / 2.0
|
||||
|
||||
|
||||
def _hours_since(day0, t):
|
||||
return (t - day0).total_seconds() / 3600.0
|
||||
|
||||
|
||||
def _day_between(day: Day, a: datetime, b: datetime, now: datetime) -> float:
|
||||
if day.periods:
|
||||
out = 0.0
|
||||
for s, e, kwh in day.periods:
|
||||
lo, hi = max(a, s), min(b, e)
|
||||
if hi > lo:
|
||||
out += kwh * (hi - lo).total_seconds() / (e - s).total_seconds()
|
||||
return out
|
||||
# State only: `kwh` is what is left from `max(now, day0)` to the day's
|
||||
# end, spread over the bell.
|
||||
h_from = _hours_since(day.day0, max(now, day.day0))
|
||||
left = 1.0 - _bell(h_from)
|
||||
if left <= 1e-9:
|
||||
return 0.0
|
||||
share = (_bell(_hours_since(day.day0, b))
|
||||
- _bell(_hours_since(day.day0, a))) / left
|
||||
return day.kwh * max(0.0, share)
|
||||
|
||||
|
||||
def _parse_time(v):
|
||||
try:
|
||||
t = datetime.fromisoformat(str(v).replace("Z", "+00:00"))
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
return t if t.tzinfo else t.replace(tzinfo=timezone.utc)
|
||||
|
||||
|
||||
def _periods(attrs: dict, day0: datetime) -> tuple:
|
||||
"""The hourly split, if the sensor has one, for the day at `day0`."""
|
||||
d1 = day0 + timedelta(days=1)
|
||||
out = []
|
||||
for key in ("detailedForecast", "detailedHourly"):
|
||||
rows = attrs.get(key)
|
||||
if isinstance(rows, list) and rows:
|
||||
starts = []
|
||||
for r in rows:
|
||||
if not isinstance(r, dict):
|
||||
continue
|
||||
t = _parse_time(r.get("period_start"))
|
||||
try:
|
||||
kw = float(r.get("pv_estimate"))
|
||||
except (TypeError, ValueError):
|
||||
continue
|
||||
if t is not None and math.isfinite(kw) and kw >= 0:
|
||||
starts.append((t, kw))
|
||||
starts.sort()
|
||||
for i, (t, kw) in enumerate(starts):
|
||||
step = (starts[i + 1][0] - t if i + 1 < len(starts)
|
||||
else timedelta(minutes=30 if key ==
|
||||
"detailedForecast" else 60))
|
||||
if step <= timedelta(0) or step > timedelta(hours=1):
|
||||
step = timedelta(minutes=30 if key == "detailedForecast"
|
||||
else 60)
|
||||
if day0 <= t < d1:
|
||||
out.append((t, t + step,
|
||||
kw * step.total_seconds() / 3600.0))
|
||||
if out:
|
||||
return tuple(out)
|
||||
wh = attrs.get("wh_period")
|
||||
if isinstance(wh, dict) and wh:
|
||||
rows = []
|
||||
for k, v in wh.items():
|
||||
t = _parse_time(k)
|
||||
try:
|
||||
e = float(v)
|
||||
except (TypeError, ValueError):
|
||||
continue
|
||||
if t is not None and math.isfinite(e) and e >= 0:
|
||||
rows.append((t, e / 1000.0))
|
||||
rows.sort()
|
||||
for i, (t, kwh) in enumerate(rows):
|
||||
nxt = rows[i + 1][0] if i + 1 < len(rows) else t + timedelta(
|
||||
hours=1)
|
||||
if nxt - t > timedelta(hours=1) or nxt <= t:
|
||||
nxt = t + timedelta(hours=1)
|
||||
if day0 <= t < d1:
|
||||
out.append((t, nxt, kwh))
|
||||
return tuple(out)
|
||||
|
||||
|
||||
def _day(state, day0, now, *, today):
|
||||
"""`(Day, None)` or `(None, why)` from one sensor's state dict."""
|
||||
if state is None:
|
||||
return None, MISSING
|
||||
raw = str(state.get("state", "")).strip()
|
||||
if raw.lower() in BAD_STATES:
|
||||
return None, MISSING
|
||||
try:
|
||||
v = float(raw)
|
||||
except ValueError:
|
||||
return None, BAD
|
||||
attrs = state.get("attributes") or {}
|
||||
unit = str(attrs.get("unit_of_measurement") or "").strip()
|
||||
if unit not in KWH_PER:
|
||||
return None, UNIT
|
||||
kwh = v * KWH_PER[unit]
|
||||
if not math.isfinite(kwh) or kwh < 0:
|
||||
return None, BAD
|
||||
periods = _periods(attrs, day0)
|
||||
if periods and today:
|
||||
# The split is the whole day; keep what is still to come, scaled so
|
||||
# it adds up to the state (the state is what the integration says
|
||||
# is left).
|
||||
left = sum(k * max(0.0, min(1.0, (e - max(s, now)).total_seconds()
|
||||
/ (e - s).total_seconds()))
|
||||
for s, e, k in periods)
|
||||
if left > 1e-6:
|
||||
f = kwh / left
|
||||
periods = tuple((s, e, k * f) for s, e, k in periods)
|
||||
return Day(day0, kwh, periods), None
|
||||
|
||||
|
||||
def _reported(state):
|
||||
ts = [_parse_time(state.get(k)) for k in
|
||||
("last_reported", "last_updated", "last_changed")]
|
||||
ts = [t for t in ts if t is not None]
|
||||
return max(ts) if ts else None
|
||||
|
||||
|
||||
def entities(opts: dict, *, tomorrow=False) -> tuple:
|
||||
"""The forecast entities one day names, in configured order: the list
|
||||
if it has any entry, else the single key, else (). A repeated id is
|
||||
dropped, as `pv.entities()` does: it would count one forecast twice."""
|
||||
one, many = TOMORROW_KEYS if tomorrow else TODAY_KEYS
|
||||
listed = [e for e in (str(x or "").strip()
|
||||
for x in (opts.get(many) or [])) if e]
|
||||
if listed:
|
||||
return tuple(dict.fromkeys(listed))
|
||||
e = str(opts.get(one) or "").strip()
|
||||
return (e,) if e else ()
|
||||
|
||||
|
||||
def _bounds(now):
|
||||
here = now.astimezone(BILLING_TZ)
|
||||
d0 = datetime(here.year, here.month, here.day, tzinfo=BILLING_TZ)
|
||||
nd = d0.date() + timedelta(days=1)
|
||||
d1 = datetime(nd.year, nd.month, nd.day, tzinfo=BILLING_TZ)
|
||||
return d0.astimezone(timezone.utc), d1.astimezone(timezone.utc)
|
||||
|
||||
|
||||
def _today(state, day0, now):
|
||||
"""`(Day, at, None)` or `(None, None, why)` for one today sensor."""
|
||||
today, why = _day(state, day0, now, today=True)
|
||||
if today is None:
|
||||
return None, None, why
|
||||
at = _reported(state)
|
||||
# A reading from before local midnight is yesterday's "left today" (0
|
||||
# after sunset) until the integration refreshes: stale, not a dark day.
|
||||
if at is None or at < day0 or (now - at).total_seconds() > FRESH_S \
|
||||
or (at - now).total_seconds() > 300:
|
||||
return None, None, STALE
|
||||
return today, at, None
|
||||
|
||||
|
||||
def _tomorrow(state, day0, day1, now):
|
||||
"""`(Day, None)` or `(None, why)` for one tomorrow sensor."""
|
||||
t, why = _day(state, day1, now, today=False)
|
||||
if t is None:
|
||||
return None, why
|
||||
t_at = _reported(state)
|
||||
if t_at is None or t_at < day0 or (now - t_at).total_seconds() > FRESH_S:
|
||||
return None, STALE
|
||||
return t, None
|
||||
|
||||
|
||||
def read(today_state, tomorrow_state, now: datetime, *,
|
||||
configured=True):
|
||||
"""`(Forecast, None)` or `(None, why)`. `tomorrow_state` may be None
|
||||
(the option is not set, or the sensor is missing): the forecast then
|
||||
covers today only."""
|
||||
if not configured:
|
||||
return None, NOT_SET
|
||||
day0, day1 = _bounds(now)
|
||||
today, at, why = _today(today_state, day0, now)
|
||||
if today is None:
|
||||
return None, why
|
||||
tomorrow = None
|
||||
if tomorrow_state is not None:
|
||||
tomorrow, _w = _tomorrow(tomorrow_state, day0, day1, now)
|
||||
return Forecast(today, tomorrow, at), None
|
||||
|
||||
|
||||
def _sum(days):
|
||||
"""One Day from several members' Days. The hourly split is kept only if
|
||||
every member has one: the splits are then joined (`_day_between()`
|
||||
adds overlapping periods). Else the total goes on the bell."""
|
||||
if len(days) == 1:
|
||||
return days[0]
|
||||
periods = ()
|
||||
if all(d.periods for d in days):
|
||||
periods = tuple(sorted(p for d in days for p in d.periods))
|
||||
return Day(days[0].day0, sum(d.kwh for d in days), periods)
|
||||
|
||||
|
||||
def read_sum(today, tomorrow, now: datetime):
|
||||
"""OPT-17: `(Forecast or None, why, gaps)` over lists of
|
||||
`(entity, state)`, one per configured member, in configured order.
|
||||
|
||||
Each member is read exactly as `read()` reads one sensor, in its own
|
||||
unit. A member that is missing, unavailable, stale, not in an energy
|
||||
unit or bad makes that DAY unusable, as one such sensor does today: no
|
||||
today means no forecast, no tomorrow means today only. A partial sum
|
||||
would under-count the sun and mislead the day plan.
|
||||
|
||||
`gaps` is `((day, position, entity, why), ...)` for every unusable
|
||||
member (`day` "today" or "tomorrow", `position` 1-based), so the page
|
||||
and the log can name it. With one member per day the forecast is what
|
||||
`read()` gives (test_opt17.py proves it)."""
|
||||
if not today:
|
||||
return None, NOT_SET, ()
|
||||
day0, day1 = _bounds(now)
|
||||
gaps, days, ats, why0 = [], [], [], None
|
||||
for i, (ent, st) in enumerate(today, 1):
|
||||
d, at, why = _today(st, day0, now)
|
||||
if d is None:
|
||||
gaps.append(("today", i, ent, why))
|
||||
why0 = why0 or why
|
||||
else:
|
||||
days.append(d)
|
||||
ats.append(at)
|
||||
tdays = []
|
||||
for i, (ent, st) in enumerate(tomorrow, 1):
|
||||
t, why = _tomorrow(st, day0, day1, now)
|
||||
if t is None:
|
||||
gaps.append(("tomorrow", i, ent, why))
|
||||
else:
|
||||
tdays.append(t)
|
||||
gaps = tuple(gaps)
|
||||
if why0 is not None:
|
||||
return None, why0, gaps
|
||||
tday = _sum(tdays) if tomorrow and len(tdays) == len(tomorrow) else None
|
||||
# The oldest member's report is when the sum was last fully known.
|
||||
return Forecast(_sum(days), tday, min(ats)), None, gaps
|
||||
@@ -100,7 +100,7 @@
|
||||
}
|
||||
function renderPill() {
|
||||
const st = S.state || null;
|
||||
const dot = st ? ({ running: "", shadow: " warn", stopped: " warn", warning: " warn", alarm: " bad" }[st.kind] ?? " warn")
|
||||
const dot = st ? ({ running: "", shadow: " warn", stopped: " warn", warning: " warn", alarm: " bad", waiting: " warn" }[st.kind] ?? " warn")
|
||||
: (S.level === "ok" ? "" : S.level === "bad" ? " bad" : " warn");
|
||||
const words = st ? [st.pill, st.ran].filter(Boolean).join(". ") : S.setup_only === true ? t("setup_only.name") : S.banner;
|
||||
$("#pill").replaceChildren(h("span", { class: "dot" + dot, "aria-hidden": "true" }), h("span", {}, words));
|
||||
@@ -399,10 +399,13 @@
|
||||
$("#batt-how").hidden = !modes;
|
||||
const docs = $("#batt-docs");
|
||||
if (S.control && S.control.docs_url) { docs.href = S.control.docs_url; docs.hidden = false; } else docs.hidden = true;
|
||||
if (S.state && ["shadow", "stopped", "alarm"].includes(S.state.kind)) banner($("#batt-banner"), S.level, S.state.pill, S.state.sub, S.level === "bad" ? "alert" : null);
|
||||
if (S.state && ["shadow", "stopped", "alarm", "waiting"].includes(S.state.kind)) banner($("#batt-banner"), S.level, S.state.pill, S.state.sub, S.level === "bad" ? "alert" : null);
|
||||
else $("#batt-banner").replaceChildren();
|
||||
keepFocus(() => {
|
||||
$("#bcards").replaceChildren(...S.batteries.map(batteryCard));
|
||||
// OPT-11 P4: the solar forecast line under the cards.
|
||||
const sl = $("#batt-solar"), line = modes && S.solar ? S.solar.line : "";
|
||||
if (sl) { sl.textContent = line || ""; sl.hidden = !line; }
|
||||
if (simpleHost && simpleHost.isConnected) {
|
||||
simpleHost.replaceChildren(...(modes ? S.batteries.map(simpleRow)
|
||||
: [h("p", { class: "small muted", style: "margin:4px 0" }, t("batteries.modes_off.name") + ". " + t("batteries.description"))]));
|
||||
|
||||
@@ -101,6 +101,7 @@
|
||||
<a class="btn" href="#settings" data-t="batteries.settings"></a>
|
||||
</div>
|
||||
<div id="bcards"></div>
|
||||
<p class="small muted" id="batt-solar" hidden></p>
|
||||
<details class="grp" id="batt-how" hidden>
|
||||
<summary><span class="grow"><strong data-t="batteries.how.name"></strong><span class="small muted gdesc" data-t="batteries.how.description"></span></span><span class="chev" aria-hidden="true">›</span></summary>
|
||||
<div class="body small">
|
||||
|
||||
@@ -446,7 +446,17 @@
|
||||
e.textContent = ok ? e.dataset.kwNote.replace("{kw}", window.UX13.kw(mp.peak_w) + " kW") : "";
|
||||
});
|
||||
}
|
||||
// OPT-11 P4: the solar forecast card shows the add-on's forecast line.
|
||||
function fillSolar() {
|
||||
const st = window.UX13.status();
|
||||
const line = st && st.solar ? st.solar.line : "";
|
||||
document.querySelectorAll("#simple [data-solar-note]").forEach((e) => {
|
||||
e.textContent = line || "";
|
||||
e.hidden = !line;
|
||||
});
|
||||
}
|
||||
document.addEventListener("ux13:status", fillNotes);
|
||||
document.addEventListener("ux13:status", fillSolar);
|
||||
function simpleField(f) {
|
||||
const row = fieldRow(f, null, "simple");
|
||||
row.querySelector(".head").append(chip(f.applies));
|
||||
@@ -458,6 +468,7 @@
|
||||
const help = row.querySelector(".help");
|
||||
if (help) help.textContent = n.description;
|
||||
}
|
||||
if (f.note === "forecast") row.append(h("div", { class: "small muted", "data-solar-note": "", hidden: true }));
|
||||
return h("div", { class: "card" }, row);
|
||||
}
|
||||
function renderSimple() {
|
||||
|
||||
@@ -1232,6 +1232,16 @@ def static_plan(opts: dict, since: datetime, until: datetime, *,
|
||||
profile, "fallback" if provisional else "static")
|
||||
|
||||
|
||||
def static_gated(opts: dict, now: datetime) -> bool:
|
||||
"""MAINT-13: is a fixed tariff set up, so that a cheap window can hold a
|
||||
charge back? False for no profile or one that cannot be used."""
|
||||
try:
|
||||
return bool(static_plan(opts, now, now + timedelta(days=MEAN_WINDOW_DAYS),
|
||||
now=now).has_prices)
|
||||
except ProfileInvalid:
|
||||
return False
|
||||
|
||||
|
||||
def static_status(opts: dict, now: datetime):
|
||||
"""(cheap, words) for the status page and for main.py's cheap-window flag.
|
||||
|
||||
|
||||
@@ -94,6 +94,7 @@ DEFAULTS = {
|
||||
"phase_started": None,
|
||||
"last_completed": None,
|
||||
"last_start_attempt": None,
|
||||
"last_failed": None,
|
||||
"sign_tripped": False,
|
||||
"sign_reason": "",
|
||||
"circ_tripped": False,
|
||||
@@ -171,7 +172,7 @@ MAINT_SCHEMA_KEY = "maint_schema_version"
|
||||
# silently stop being migrated - the same property `UNIT_STORE_KEYS` gives the
|
||||
# SAFETY-02 pair.
|
||||
MAINT_UNIT_KEYS = ("phase", "phase_started", "last_completed",
|
||||
"last_start_attempt")
|
||||
"last_start_attempt", "last_failed")
|
||||
|
||||
|
||||
def unit_key(unit: str, key: str) -> str:
|
||||
|
||||
@@ -835,6 +835,22 @@ class PeakTracker:
|
||||
held_w=averager.held_net_w)
|
||||
|
||||
|
||||
def next_quarter(p: Projection, max_hold_s: float) -> Projection:
|
||||
"""SAFETY-91: `p` past its block's end, before the next block's first
|
||||
telegram: the next quarter, projected from the held reading (the averager
|
||||
credits it there). `p` itself otherwise, or when that reading is too old
|
||||
to be credited. DECISIONS/SAFETY-91-held-battery-last.md."""
|
||||
if p.block_start is None or p.elapsed_s < QUARTER_S \
|
||||
or p.elapsed_s * (1.0 - p.covered_frac) > float(max_hold_s):
|
||||
return p
|
||||
held = max(p.held_w, 0.0)
|
||||
return Projection(projected_w=held, elapsed_w=held,
|
||||
elapsed_s=p.elapsed_s - QUARTER_S, covered_frac=1.0,
|
||||
complete=True,
|
||||
block_start=p.block_start + timedelta(seconds=QUARTER_S),
|
||||
held_w=p.held_w)
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class _ClosedBlock:
|
||||
"""A block reconstructed from a checkpoint. Shaped like `p1.QuarterBlock` so
|
||||
|
||||
@@ -119,7 +119,7 @@
|
||||
"description": "Every setting, grouped by task.",
|
||||
"view": {"name": "Settings view", "simple": "Simple", "installer": "Installer"},
|
||||
"simple": {"description": "The choices a home owner makes.",
|
||||
"note": {"month_peak": {"description": "This month's peak so far: {kw}."}, "shadow": {"description": "Use Always on while you test a new installation."}},
|
||||
"note": {"month_peak": {"description": "This month's peak so far: {kw}."}, "shadow": {"description": "Use Always on while you test a new installation."}, "forecast": {"description": "With a forecast, a battery buys only what the sun will not give."}},
|
||||
"batteries": {"name": "Batteries"},
|
||||
"more": {"description": "Looking for the meter, inverters or prices?"},
|
||||
"installer": "Open the installer view"},
|
||||
@@ -267,6 +267,7 @@
|
||||
"shadow": "Shadow mode",
|
||||
"stopped": "Stopped",
|
||||
"alarm": "Needs you now",
|
||||
"waiting": "Waiting for Home Assistant",
|
||||
"warning": "Running, with a warning"
|
||||
},
|
||||
"banner_sub": {
|
||||
@@ -274,6 +275,7 @@
|
||||
"shadow": "The plans below say what the add-on would do.",
|
||||
"stopped": "Start control below when you are ready.",
|
||||
"alarm": "See Needs attention below for what to do.",
|
||||
"waiting": "Control resumes by itself when Home Assistant answers.",
|
||||
"warning": "See Needs attention below."
|
||||
},
|
||||
"tile": {
|
||||
@@ -327,6 +329,7 @@
|
||||
"leftover_alone": "No Solar first battery is on, so it gets solar first.",
|
||||
"covers_house": "It gives power to cover the house.",
|
||||
"other_refuses": "{name} refuses to give power, so this battery takes over.",
|
||||
"other_cycle": "{name} is emptying for its monthly cycle. This one does not charge.",
|
||||
"grid_charge": "Prices are low, so it charges from the grid.",
|
||||
"rests_charge": "Another battery charges from the grid, so it rests.",
|
||||
"selling": "Prices are high, so it sells to the grid.",
|
||||
@@ -334,8 +337,12 @@
|
||||
"saves": "Saves its power for {at}.",
|
||||
"saves_later": "Saves its power for higher prices.",
|
||||
"no_prices": "No prices, so it follows the house.",
|
||||
"no_spread": "Prices differ too little, so it follows the house."
|
||||
"no_spread": "Prices differ too little, so it follows the house.",
|
||||
"sun_fills": "Enough sun is forecast, so it does not charge from the grid.",
|
||||
"tops_up": "Too little sun is forecast, so it charges some from the grid.",
|
||||
"no_forecast": "No solar forecast, so it charges from solar only."
|
||||
},
|
||||
"solar": {"line": "Solar still to come today: {kwh}, we count on {count}. Updated {at}.", "no_forecast": "No solar forecast now, so Leftover solar charges from solar only.", "learning": "The add-on is learning your house's use. The plan starts after one full day."},
|
||||
"today": {
|
||||
"not_planned": "Not planned yet.",
|
||||
"no_runs": "No cheap or expensive hours left today.",
|
||||
@@ -405,6 +412,7 @@
|
||||
"step_in": "The batteries step in above {kw}.",
|
||||
"step_in_would": "The batteries would step in above {kw}.",
|
||||
"period": "This 15-minute period is heading for {kw}.",
|
||||
"period_unmeasured": "Part of this 15-minute period was not measured.",
|
||||
"prices": {
|
||||
"now": "Price now {eur} per kWh, all in.",
|
||||
"today": "Today: lowest {lo} at {lo_at}, highest {hi} at {hi_at}.",
|
||||
@@ -425,6 +433,7 @@
|
||||
"stopped": "Control is stopped. Every inverter is at 0 W."
|
||||
},
|
||||
"attn": {
|
||||
"home_assistant": "Home Assistant is not answering",
|
||||
"controller": "Control is not running",
|
||||
"meter": "Meter reading",
|
||||
"meter_frozen": "Meter reading may be stuck",
|
||||
@@ -443,6 +452,7 @@
|
||||
"delivery": "An inverter is not delivering",
|
||||
"estop": "Emergency stop",
|
||||
"pv": "Solar reading",
|
||||
"solar_forecast": "Solar forecast",
|
||||
"none": "Inverter connection"
|
||||
},
|
||||
"months": ["January", "February", "March", "April", "May", "June", "July", "August", "September", "October", "November", "December"]
|
||||
|
||||
@@ -114,7 +114,7 @@
|
||||
"description": "Elke instelling, per taak.",
|
||||
"view": {"name": "Weergave van de instellingen", "simple": "Eenvoudig", "installer": "Installateur"},
|
||||
"simple": {"description": "De keuzes die een eigenaar maakt.",
|
||||
"note": {"month_peak": {"description": "De piek van deze maand tot nu: {kw}."}, "shadow": {"description": "Kies Altijd aan terwijl u een nieuwe installatie test."}},
|
||||
"note": {"month_peak": {"description": "De piek van deze maand tot nu: {kw}."}, "shadow": {"description": "Kies Altijd aan terwijl u een nieuwe installatie test."}, "forecast": {"description": "Met een prognose koopt een batterij alleen wat de zon niet geeft."}},
|
||||
"batteries": {"name": "Batterijen"},
|
||||
"more": {"description": "Zoekt u de meter, de omvormers of de prijzen?"},
|
||||
"installer": "De installateursweergave openen"},
|
||||
@@ -230,8 +230,8 @@
|
||||
"zero_held": "Op 0 W gehouden",
|
||||
"zero_going": "Gaat naar 0 W",
|
||||
"verdict": {"held": "Op 0 W gehouden", "stopped": "Gestopt", "cycle": "Vandaag maandelijkse cyclus", "trade": "Handelt op prijs", "house": "Volgt het huis"},
|
||||
"pill": {"running": "Actief", "shadow": "Schaduwmodus", "stopped": "Gestopt", "alarm": "Heeft u nu nodig", "warning": "Actief, met een waarschuwing"},
|
||||
"banner_sub": {"running": "De batterijen volgen het plan hieronder.", "shadow": "De plannen hieronder tonen wat de add-on zou doen.", "stopped": "Start de regeling hieronder als u klaar bent.", "alarm": "Zie Vraagt aandacht hieronder voor wat u moet doen.", "warning": "Zie Vraagt aandacht hieronder."},
|
||||
"pill": {"running": "Actief", "shadow": "Schaduwmodus", "stopped": "Gestopt", "alarm": "Heeft u nu nodig", "waiting": "Wacht op Home Assistant", "warning": "Actief, met een waarschuwing"},
|
||||
"banner_sub": {"running": "De batterijen volgen het plan hieronder.", "shadow": "De plannen hieronder tonen wat de add-on zou doen.", "stopped": "Start de regeling hieronder als u klaar bent.", "alarm": "Zie Vraagt aandacht hieronder voor wat u moet doen.", "waiting": "De regeling gaat vanzelf verder zodra Home Assistant antwoordt.", "warning": "Zie Vraagt aandacht hieronder."},
|
||||
"tile": {"not_set_up": "Niet ingesteld", "no_reading": "Geen meting", "producing": "Produceert", "not_producing": "Produceert niet", "needs_solar": "Zonnemeting nodig", "not_adding_up": "Metingen kloppen niet", "using": "Verbruikt", "taking": "Neemt af van het net", "feeding": "Injecteert", "balanced": "In evenwicht", "giving": "Levert stroom", "charging": "Laadt", "resting": "Rust"},
|
||||
"now": {
|
||||
"no_reading": "Geen meting van deze batterij.",
|
||||
@@ -269,6 +269,7 @@
|
||||
"leftover_alone": "Geen batterij met Eerst zonne-energie staat aan, dus zij krijgt eerst zonne-energie.",
|
||||
"covers_house": "Ze levert stroom om het huis te dekken.",
|
||||
"other_refuses": "{name} weigert te leveren, dus deze batterij neemt het over.",
|
||||
"other_cycle": "{name} loopt leeg voor haar maandelijkse cyclus. Deze laadt niet.",
|
||||
"grid_charge": "De prijs is laag, dus ze laadt van het net.",
|
||||
"rests_charge": "Een andere batterij laadt van het net, dus deze rust.",
|
||||
"selling": "De prijs is hoog, dus ze verkoopt aan het net.",
|
||||
@@ -276,8 +277,12 @@
|
||||
"saves": "Spaart haar stroom voor {at}.",
|
||||
"saves_later": "Spaart haar stroom voor hogere prijzen.",
|
||||
"no_prices": "Geen prijzen, dus ze volgt het huis.",
|
||||
"no_spread": "De prijzen verschillen te weinig, dus ze volgt het huis."
|
||||
"no_spread": "De prijzen verschillen te weinig, dus ze volgt het huis.",
|
||||
"sun_fills": "Er is genoeg zon voorspeld, dus ze laadt niet van het net.",
|
||||
"tops_up": "Te weinig zon voorspeld, dus ze laadt wat van het net.",
|
||||
"no_forecast": "Geen zonneprognose, dus ze laadt alleen met zonne-energie."
|
||||
},
|
||||
"solar": {"line": "Nog verwachte zon vandaag: {kwh}, we rekenen op {count}. Bijgewerkt om {at}.", "no_forecast": "Nu geen zonneprognose, dus Overschot zonne-energie laadt alleen met zon.", "learning": "De add-on leert eerst het verbruik van uw huis. Het plan start na één volle dag."},
|
||||
"today": {
|
||||
"not_planned": "Nog niet gepland.",
|
||||
"no_runs": "Vandaag geen goedkope of dure uren meer.",
|
||||
@@ -342,12 +347,14 @@
|
||||
"step_in": "De batterijen springen bij boven {kw}.",
|
||||
"step_in_would": "De batterijen zouden bijspringen boven {kw}.",
|
||||
"period": "Dit kwartier gaat richting {kw}.",
|
||||
"period_unmeasured": "Een deel van dit kwartier is niet gemeten.",
|
||||
"prices": {"now": "Prijs nu {eur} per kWh, alles inbegrepen.", "today": "Vandaag: laagste {lo} om {lo_at}, hoogste {hi} om {hi_at}.", "none": "Geen prijzen voor vandaag."},
|
||||
"tomorrow": {"known": "De prijzen van morgen zijn binnen.", "unknown": "De prijzen van morgen komen meestal na 13:00."},
|
||||
"region": {"preset": "Heffingen en btw: {region}, cijfers van {year}.", "own": "Heffingen en btw: uw eigen bedrag."},
|
||||
"peak_not_covered": "Geen piekgrens: deze meter meet geen kwartieren.",
|
||||
"control": {"shadow": "Schaduwmodus: elke omvormer blijft op 0 W.", "running": "De regeling is actief.", "stopped": "De regeling is gestopt. Elke omvormer staat op 0 W."},
|
||||
"attn": {
|
||||
"home_assistant": "Home Assistant antwoordt niet",
|
||||
"controller": "Regeling is niet actief",
|
||||
"meter": "Meting van de meter",
|
||||
"meter_frozen": "Meter staat mogelijk vast",
|
||||
@@ -366,6 +373,7 @@
|
||||
"delivery": "Een omvormer levert niet",
|
||||
"estop": "Noodstop",
|
||||
"pv": "Meting van de zonnepanelen",
|
||||
"solar_forecast": "Zonneprognose",
|
||||
"none": "Verbinding met de omvormer"
|
||||
},
|
||||
"months": ["januari", "februari", "maart", "april", "mei", "juni", "juli", "augustus", "september", "oktober", "november", "december"]
|
||||
|
||||
@@ -129,7 +129,18 @@ GROUPS = (
|
||||
wizard=3),)),
|
||||
# OPT-11: the switch that turns battery modes on. Each battery's mode
|
||||
# and on/off switch are runtime state on the Batteries screen.
|
||||
Part("modes", (Field("battery_modes_enabled", TOGGLE),)),
|
||||
Part("modes", (
|
||||
Field("battery_modes_enabled", TOGGLE),
|
||||
# OPT-11 P4: the solar forecast; today's also on Settings, Simple.
|
||||
Field("pv_forecast_entity", ENTITY, kind="energy", simple=True,
|
||||
note="forecast"),
|
||||
Field("pv_forecast_tomorrow_entity", ENTITY, kind="energy"),
|
||||
# OPT-17: several forecast sensors per day, summed.
|
||||
Field("pv_forecast_entities", ENTITY_LIST, kind="energy"),
|
||||
Field("pv_forecast_tomorrow_entities", ENTITY_LIST,
|
||||
kind="energy"),
|
||||
Field("solar_trust_pct", SLIDER, "%", step=5),
|
||||
)),
|
||||
)),
|
||||
Group("tariff", (
|
||||
Part("", (
|
||||
|
||||
@@ -246,6 +246,10 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
12. `peak_margin_w` outside 0-500 W, not whole, or not below `peak_cap_w`.
|
||||
SAFETY-79; the Supervisor checks the range too, but not for sim/inject.py.
|
||||
|
||||
13. OPT-11 P4: `solar_trust_pct` outside 30-100 or not whole, or a solar
|
||||
forecast entity that is not a `sensor.` id. A trust of 0 or 500 % would
|
||||
make the day plan buy everything or nothing, which no one means.
|
||||
|
||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
|
||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||
@@ -324,9 +328,10 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
"""
|
||||
|
||||
import logging
|
||||
import re
|
||||
from typing import NamedTuple
|
||||
|
||||
from . import messages, pv
|
||||
from . import dayplan, messages, pv, solarfc
|
||||
from .arbitrage import enabled as arbitrage_on
|
||||
from .control import SLEW_RAIL_FRAC, LOOP_TICK_S, PLANT_SETTLE_S
|
||||
from .custom_formula import (
|
||||
@@ -1199,6 +1204,7 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None,
|
||||
|
||||
# --- 12. SAFETY-79: the margin the peak guard keeps under the limit -----
|
||||
problems += _margin_problems(opts)
|
||||
problems += _forecast_problems(opts)
|
||||
|
||||
# --- warnings: real, but not worth refusing over -------------------------
|
||||
integ = opts.get("integrator_max_w")
|
||||
@@ -1751,6 +1757,8 @@ def _entities_read(opts: dict) -> list[tuple[str, str, str]]:
|
||||
add("pv_entities" if solar else "pv_entity", list(pv.entities(opts)))
|
||||
for key in ("peak_forecast_entity", "price_now_entity", "price_avg_entity"):
|
||||
add(key, opts.get(key))
|
||||
for key in FORECAST_KEYS:
|
||||
add(key, opts.get(key))
|
||||
return out
|
||||
|
||||
|
||||
@@ -1790,6 +1798,20 @@ def _entity_notes(notes, opts: dict, entities: dict, bad=()) -> None:
|
||||
_advise(notes, "warn", (key,),
|
||||
f"{entity} reads in {unit}, but {S(key, where)} is "
|
||||
"taken as watts, so pick a sensor in W.")
|
||||
if key in FORECAST_KEYS and unit not in solarfc.KWH_PER:
|
||||
_advise(notes, "warn", (key,),
|
||||
f"{entity} does not read in kWh, so pick a solar "
|
||||
"forecast sensor in kWh.")
|
||||
today = solarfc.entities(opts)
|
||||
tomorrow = solarfc.entities(opts, tomorrow=True)
|
||||
if (today or tomorrow) and \
|
||||
opts.get("battery_modes_enabled") is not True:
|
||||
_advise(notes, "info", ("pv_forecast_entity",),
|
||||
"The solar forecast is used only with battery modes on.")
|
||||
if tomorrow and not today:
|
||||
_advise(notes, "warn", ("pv_forecast_tomorrow_entity",),
|
||||
"Tomorrow's forecast is used only with today's, so set "
|
||||
f"{S('pv_forecast_entity')} too.")
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
@@ -2045,6 +2067,50 @@ def _margin_problems(opts: dict) -> list[str]:
|
||||
return []
|
||||
|
||||
|
||||
TRUST_RANGE_PCT = (30, 100)
|
||||
# A Home Assistant sensor id; it goes into the /api/states/<id> path.
|
||||
_SENSOR_ID = re.compile(r"sensor\.[a-z0-9_]+")
|
||||
FORECAST_KEYS = solarfc.TODAY_KEYS + solarfc.TOMORROW_KEYS
|
||||
|
||||
|
||||
def _forecast_problems(opts: dict) -> list[str]:
|
||||
"""Rule 13 (OPT-11 P4): the trust is a whole percentage in range, and
|
||||
each forecast entity set is a sensor. OPT-17: a day names its forecast
|
||||
in the single key or in the list, not both."""
|
||||
out = []
|
||||
raw = opts.get("solar_trust_pct")
|
||||
trust = _number(opts, "solar_trust_pct", dayplan.DEFAULT_TRUST_PCT)
|
||||
lo, hi = TRUST_RANGE_PCT
|
||||
if trust is None or trust != int(trust) or not lo <= trust <= hi:
|
||||
out.append(f"{S('solar_trust_pct')} must be a whole number from {lo} "
|
||||
f"to {hi} %. It is {messages.shown(raw)}.")
|
||||
for one, many in (solarfc.TODAY_KEYS, solarfc.TOMORROW_KEYS):
|
||||
e = opts.get(one)
|
||||
if e is not None and e != "" and (
|
||||
not isinstance(e, str) or not _SENSOR_ID.fullmatch(e)):
|
||||
out.append(f"{S(one)} must be a sensor, like "
|
||||
f"sensor.energy_production_today_remaining. It is "
|
||||
f"{messages.shown(e)}.")
|
||||
raw = opts.get(many)
|
||||
if raw is None:
|
||||
raw = []
|
||||
if not isinstance(raw, list):
|
||||
out.append(f"{S(many)} must be a list of sensors. It is "
|
||||
f"{messages.shown(raw)}.")
|
||||
continue
|
||||
listed = [x for x in raw if x is not None
|
||||
and not (isinstance(x, str) and not x.strip())]
|
||||
for x in listed:
|
||||
if not isinstance(x, str) or not _SENSOR_ID.fullmatch(x):
|
||||
out.append(f"{S(many)} must list only sensors, like "
|
||||
f"sensor.energy_production_today_remaining. "
|
||||
f"It has {messages.shown(x)}.")
|
||||
if e and listed:
|
||||
out.append(f"Set {S(one)} or {S(many)}, not both. Keep the "
|
||||
f"list and clear the single one.")
|
||||
return out
|
||||
|
||||
|
||||