Merge release/1.0 (e3e4ba6) into opt15-price-run-fixes
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
clears the chargers, a probing refuser included, while a battery drains
(SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
(`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.
Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
until the quarter's first sample, as the old edge tick was not, so a
standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
drain and the day plan against the probe.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -285,32 +285,11 @@ cross-inverter `lo > hi` contradiction at `arbiter.py:114`. The only line this
|
||||
card changed there is **which** roster entry the claim is filed on: the one whose
|
||||
state machine produced the result, rather than `inverters[0]`.
|
||||
|
||||
## 6. FOUND AND NOT FIXED: the site loop still contradicts a drain at N>=2
|
||||
## 6. FIXED BY SAFETY-78: the site loop contradicted a drain at N>=2
|
||||
|
||||
Measured while wiring this card, and **pre-existing on `release/1.0` at
|
||||
`2d025ee`** — the same drain filed on `inverters[0]` produces the identical
|
||||
refusal with the two unit names swapped.
|
||||
|
||||
The maintenance SET **pins** its pack. The loop's target is a **site** claim.
|
||||
When the site target is *below* the pin — a 2000 W drain while the house imports
|
||||
less than that, which is most of a night — the only split that sums to the site
|
||||
target asks the sibling to **charge** while the maintained pack **discharges**,
|
||||
and `allocator.plan()` refuses it by name as circulating power. The refusal is
|
||||
correct and fails safe: the whole site goes to 0 W with an `ARBITER: REFUSED`
|
||||
line in the action log.
|
||||
|
||||
**The consequence an operator would see is a misdiagnosis.** The pack is held at
|
||||
0 W while its state machine believes it is draining, so after 12 h the DRAIN
|
||||
timeout fires and reports *"drain stuck"* — §12's words for a battery that is not
|
||||
following commands. The battery is fine; the site refused to allocate.
|
||||
|
||||
**Why it is not fixed here.** The fix is to change what the site loop's target
|
||||
*means* while a unit is pinned — regulate the meter using only the unpinned
|
||||
packs — which is loop and allocator territory and changes the integrator's
|
||||
subject. MAINT-05 moves which pack is pinned and nothing else about it. It is
|
||||
pinned as a running check (`test_maintenance.py` part 12) rather than left as a
|
||||
comment, so it cannot be forgotten or quietly tuned away, and it wants a card of
|
||||
its own.
|
||||
Found here and pre-existing: below the pin the other pack had to charge, the
|
||||
allocator refused it and the site sat at 0 W. Fixed by a site `drain` floor;
|
||||
see [[SAFETY-78]] (`DECISIONS/SAFETY-78-drain-at-two.md`).
|
||||
|
||||
## 7. FOUND AND NOT FIXED: `migrate_unit_keys()` has the same hole, and it is a LATCH
|
||||
|
||||
|
||||
@@ -0,0 +1,67 @@
|
||||
# MAINT-10 — the maintenance start hour is local time, default 19:00
|
||||
|
||||
Owner decision 2026-09-29 (option A). `maintenance_start_hour` was compared
|
||||
with the UTC hour, so the shipped 10 started at 12:00 in a Belgian summer and
|
||||
11:00 in winter. It is now read on the site's local clock, and the default moves
|
||||
to 19 so the drain runs into the evening and night rather than the solar day.
|
||||
|
||||
Evening drains meet higher house loads; SAFETY-83 (merged first) lets the
|
||||
peak guard outrank the drain.
|
||||
|
||||
## 1. Which zone
|
||||
|
||||
Home Assistant's `time_zone` (`GET /core/api/config`, 3 s budget) at startup,
|
||||
else the container's `TZ`, else UTC. One log line says which (WARNING only for
|
||||
UTC). Resolved once per start: a zone change in HA takes effect on the next
|
||||
add-on restart. HA can still be starting when the add-on starts (502 from the
|
||||
proxy, 2026-10-05); then `TZ` holds. HA pushes its zone to the Supervisor
|
||||
(hassio `push_config`), which stores it and sets it as the add-on's `TZ`
|
||||
(`docker/app.py`, Supervisor 2026.08.0), so the hour stays right. Only a `TZ` of
|
||||
UTC there logs a WARNING asking for a restart. No later re-resolve: the fallback
|
||||
already is HA's zone, so the rare UTC case gets a warning rather than more code.
|
||||
The add-on image has tzdata (checked in `amd64-base:3.20`); the CI image does
|
||||
not, so the tests grade DST on `tariff._EUTimezone` too.
|
||||
|
||||
## 2. DST
|
||||
|
||||
`maintenance.in_start_slot()` works from UTC instants only, so it does not
|
||||
depend on how a tzinfo resolves a missing or doubled wall time:
|
||||
|
||||
- normally the slot is the local hour `start_hour`;
|
||||
- clocks forward and the hour does not exist: the first hour after the jump;
|
||||
- clocks back and the hour happens twice: the first pass only. Without this an
|
||||
aborted start (90 min cooldown) would start again in the 120 min repeated hour.
|
||||
|
||||
Every day has exactly one 60 min slot for every hour 0-23: checked against
|
||||
zoneinfo for Europe/Brussels, America/New_York, America/Santiago (midnight
|
||||
transitions), Asia/Kathmandu (+05:45) and Australia/Lord_Howe (30 min DST)
|
||||
over all of 2026.
|
||||
|
||||
## 3. Existing installs
|
||||
|
||||
The Supervisor merges the shipped defaults under the STORED options, and saving
|
||||
the settings stores every key (the reference install's blob has all 76). So
|
||||
almost every existing install keeps its stored 10, which now means 10:00 local
|
||||
instead of 12:00 (summer) or 11:00 (winter). Only a blob without the key gets 19.
|
||||
The add-on does not rewrite a stored option: a silent migration would override
|
||||
an operator's choice with no way to tell it apart from the old default. A site
|
||||
that set an earlier hour to make up for UTC (17 for 19:00 summer) must set it
|
||||
back to 19 after the upgrade, or it starts two hours early. DOCS and the release
|
||||
note (drafted on the PR, for the version bump) say this.
|
||||
`tools/supervisor_shape_probe.py` §I measures this on Supervisor 2026.08.0.
|
||||
|
||||
## 4. Two inverters
|
||||
|
||||
`Controller` hands the same zone to every pack's `Maintenance`, so every pack's
|
||||
`wants_start()` reads the local hour. `arbitrate()` is unchanged: one pack
|
||||
cycles at a time, and the one that lost the slot starts in the first start
|
||||
slot after the other is done (a later day: a cycle outlasts its start hour). On the day the clocks go back, a pack freed during the second pass of
|
||||
a repeated hour does not start there. `test_maint10.py` part 10.
|
||||
|
||||
## 5. What does not change
|
||||
|
||||
Only the start decision (`Maintenance.wants_start`) and the Home screen's shown
|
||||
start time read the zone. `test_maint10.py` parts 9 and 10 run the real
|
||||
Controller at N=1 and N=2 with start hour 11 UTC against 13 Europe/Brussels (the
|
||||
same instant): every command, claim, reason and log line is identical. A
|
||||
`Maintenance` built without a zone reads UTC, as before.
|
||||
@@ -0,0 +1,109 @@
|
||||
# MAINT-13 - a full pack that stops at 98-99 % is not a failed charge
|
||||
|
||||
**Status: for review.** Tests: `test_maint13.py`. No option added; every number
|
||||
is a constant in `app/maintenance.py`.
|
||||
|
||||
**What happened (live, B).** The drain ended 2026-10-04 18:24 UTC and the charge
|
||||
began. It ran in pieces behind the price gate, reached 99 % at 2026-10-06 04:00,
|
||||
fell back to 98 % at 04:15 while the loop still asked about -1370 W, and never
|
||||
reached `maintenance_soc_target` 100. At 06:24 (2160 min = 36 h of wall clock
|
||||
after the charge began) it aborted "charge stuck at 98 %". `last_completed` was
|
||||
not set, so B was still due and would have drained again from 98 % to 11 % at the
|
||||
next start hour, with no notice. Three faults: a pack may never report 100 %
|
||||
while the BMS balances; a failed cycle came back the next day; and the 36 h
|
||||
counted hours the price gate kept the pack waiting.
|
||||
|
||||
## 1. The charge is complete when
|
||||
|
||||
1. SoC >= target (as before), or
|
||||
2. SoC >= target - 3 (`CHARGE_NEAR_FULL_PCT`) and the SoC has not beaten its
|
||||
best for 60 min (`CHARGE_STALL_MIN`) of allowed charging, or
|
||||
3. the charging time (`CHARGE_TIMEOUT_MIN`, 2160 min) runs out at SoC >= target - 3.
|
||||
|
||||
Then the usual HOLD follows and `last_completed` is set after it. Each of 2 and
|
||||
3 logs one plain line ("the battery takes no more charge at 98 %, so the charge
|
||||
counts as done", "charge time is up at 98 %, close enough to full ...").
|
||||
|
||||
**Why "SoC has not beaten its best", and not asked/delivered watts.** SoC is the
|
||||
one signal the live record gives us (99 at 04:00, 98 at 04:15); the asked power
|
||||
was -1370 W but no delivered figure was kept, so a watt threshold (X, Y) would be
|
||||
invented. SoC also covers the case where power flows but nothing is stored.
|
||||
**Why 3 points.** The card's band; at target 100 it is 97, and the live pack sat
|
||||
at 98-99. **Why 60 min.** A judgement, not a measurement: we have no per-minute record of
|
||||
the pack taking charge near full. The one live fact is 2 h 24 min (04:00 to
|
||||
06:24) without a new high, so 60 min is well inside it and long enough that a
|
||||
pack still creeping up (one new high within the hour) keeps resetting the wait.
|
||||
On the live run the rule fires after 60 gate-open minutes past the 99 %: 05:00
|
||||
UTC at the earliest, before 06:24 if the gate was open. If the pack turns out to
|
||||
step up more slowly than that, raise the constant. Falling back by one point
|
||||
does not reset the wait; only a new best does.
|
||||
|
||||
## 2. A failed cycle backs off 7 days
|
||||
|
||||
A drain stuck 12 h or a charge that times out below target - 3 is a failure
|
||||
(`FAIL_BACKOFF_DAYS` = 7). The machine goes IDLE as before, `last_failed` is
|
||||
stored, and `wants_start()` is false until 7 days later. The operator's forced
|
||||
start ignores it; a cycle that completes after the failure ends it. An operator
|
||||
abort, an interlock stop and a switched-off pack are not failures.
|
||||
|
||||
**Why 7 days, not the 28 day interval.** A judgement: a failure may have a
|
||||
short cause (several dull days with no cheap hours, a pack switched off), and
|
||||
waiting the full interval leaves the coulomb counter uncalibrated for a month
|
||||
more. A week is long enough that a bad pack costs one drain a week, with one
|
||||
notice a week, not one a day. **Cost.** A truly faulty pack still drains once a week until someone looks;
|
||||
the notice says so each time.
|
||||
|
||||
**Notice, once.** The tick that fails carries `failed`; the Controller sends one
|
||||
persistent notification "Battery cycle did not finish" (EN, with the Dutch
|
||||
below it; per pack at N=2). It is not repeated, and Home Assistant restarts
|
||||
wipe it, so the status page shows a "Maintenance paused" row with the date for
|
||||
as long as the wait lasts. The operator may also see the log lines.
|
||||
|
||||
## 3. The timeout counts only allowed time
|
||||
|
||||
`Controller._charge_gate_open()` says whether the pack may charge now. It is
|
||||
true when no price gate is set up (no price entities, no fixed tariff: nothing
|
||||
holds the charge back, and `cheap` is always false there), in a cheap window, or
|
||||
while the pack is really taking charge (battery power at or below -50 W, which is
|
||||
sun outside cheap hours). It is false only when a gate exists, is shut, and the
|
||||
pack is not charging; a pack asked for charge that delivers nothing then does not
|
||||
count, which is the case the clock cannot judge. A site with a price provider
|
||||
(TARIFF-11) and no fixed tariff counts as having no gate: the provider's plan
|
||||
reaches only the Tariff row, never `cheap`, so no cheap window ever opens a grid
|
||||
top-up there and only the sun charges the pack, as on a site with no tariff. Its
|
||||
time counts in full. When a provider plan starts to drive `cheap`,
|
||||
`_price_gated` must become true for it. Whether a fixed tariff is set up is
|
||||
worked out once an hour, not on every tick. Only open ticks add to `open_min`; one tick
|
||||
adds at most 5 min, so a gap (add-on down) adds nothing. The stall wait pauses
|
||||
while the gate is closed. The accounting is written to the state file at most
|
||||
every 5 min (`charge_track`); a restart loses at most that. A state file from
|
||||
before this change, or with no record for the current charge, starts from the
|
||||
wall-clock minutes so far, which is the old behaviour.
|
||||
|
||||
**Backstop.** A gated site whose gate never opens (no cheap hours, no sun) would never time
|
||||
out, so a charge also ends after 7 days of wall clock (`CHARGE_WALL_TIMEOUT_MIN`):
|
||||
complete at >= target - 3, a failure below.
|
||||
|
||||
**MAINT-12.** This is the smallest change that makes the timeout honest: one
|
||||
boolean in, one counter. MAINT-12's block plan can replace the boolean (the
|
||||
minutes it plans are the allowed ones) without touching the rest. Two things it
|
||||
must keep: the back-off is in `wants_start()`, so any new entry point (such as
|
||||
`price_forecast.begin_phase`, which is not wired today) must go through it or
|
||||
check `backoff_until()`; and `gate_open` must stay "the pack is allowed to
|
||||
charge now". The peak guard pausing the charge shaping is not seen as a closed
|
||||
gate: that time still counts.
|
||||
|
||||
## 4. What does not change, and what this does not cover
|
||||
|
||||
- The drain, the HOLD, the held-battery rules and `arbitrate()` are unchanged. A
|
||||
backed-off pack does not want a start, so at N=2 the other pack may take the
|
||||
slot. One pack at a time at N=1 and N=2.
|
||||
- `last_failed` is a maintenance key and moves with the others when a second
|
||||
inverter is added (`MAINT_UNIT_KEYS`). The charge record is not moved; it
|
||||
restarts from the wall-clock minutes.
|
||||
- It does not find out why a pack stopped. A pack that stops at 96 % and never
|
||||
gets near is still a failure.
|
||||
- The Dutch text is only in the notification. The status row and the log lines
|
||||
are English, like the rest of the status page.
|
||||
- It does not change the target: a site that wants a different stop point sets
|
||||
`maintenance_soc_target`.
|
||||
@@ -0,0 +1,68 @@
|
||||
# MAINT-14 - no SoC reading in a maintenance cycle
|
||||
|
||||
**Status: for review.** Tests: `test_maint14.py`. No option added; the one new
|
||||
number is a constant in `app/maintenance.py`.
|
||||
|
||||
**The fault.** `Maintenance.tick()` returned early when the SoC was `None`,
|
||||
before any timeout check. (1) A charge on a pack whose SoC reading was lost
|
||||
never ended: no timeout, no back-off, no notice, and the 7-day backstop of
|
||||
MAINT-13 sat behind the same return. (2) A drain kept commanding `discharge_w`
|
||||
with an unknown level, which breaks the TEL-08 rule that an unknown level never
|
||||
allows discharge.
|
||||
|
||||
## Rules
|
||||
|
||||
1. **Charge, no SoC.** The charge timeout (`CHARGE_TIMEOUT_MIN`, gate-open
|
||||
minutes) and the 7-day wall backstop still run. When one fires: if the last
|
||||
SoC seen was >= target - 3 the charge counts as done (the MAINT-13 "close
|
||||
enough to full" rule, HOLD follows); otherwise it fails: MAINT-13 back-off
|
||||
and its one notification. If no SoC was ever seen, it fails.
|
||||
2. **Drain, no SoC.** DRAIN holds at 0 W and owns the setpoint, exactly as HOLD
|
||||
does. The 12 h drain timeout still runs and fails as before.
|
||||
3. **SoC comes back.** Nothing is recorded; the drain continues at the drain
|
||||
rate, the charge carries on, and the stall wait of MAINT-13 restarts from
|
||||
what it was: it paused while the reading was missing, so a gap never counts
|
||||
as "no more charge".
|
||||
4. **HOLD** is unchanged (0 W).
|
||||
5. **Log.** One line when a drain starts holding for this reason ("the battery
|
||||
level is unknown, so the drain holds at 0 W until it is back"), and one line
|
||||
when the level has been missing for `NOSOC_NOTE_MIN` = 15 min. Both are said
|
||||
once per episode; the old line that repeated every tick is gone.
|
||||
|
||||
## Why
|
||||
|
||||
- **"Last seen", not "best seen".** A pack that was at 99 and then dropped to 50
|
||||
before the reading went is not close to full. Only the last reading counts.
|
||||
It is saved with the charge record (`charge_track.last`), and saved at once
|
||||
when the reading first goes missing, so a restart mid-gap still knows it
|
||||
(within the usual 5 min save interval otherwise).
|
||||
- **Failure when nothing was seen.** With no level we cannot call a pack full.
|
||||
The failure costs a 7-day wait and one notice; calling it done costs a
|
||||
missed balance and a month-long false "complete". The first is the honest one.
|
||||
- **Timeouts count the same minutes as with a reading.** Gate-open charging
|
||||
minutes only; the wall backstop for a gate that never opens.
|
||||
- **15 min.** A judgement. A poll glitch of a few minutes should not write a
|
||||
line; a reading lost for a quarter of an hour is worth one. Raise it if the
|
||||
action log shows noise.
|
||||
- **0 W, not "stop the phase".** Aborting a drain on a short gap would throw
|
||||
away the part already drained. Holding at 0 W loses nothing and the 12 h
|
||||
timeout is the limit.
|
||||
|
||||
## Cost
|
||||
|
||||
- A drain that loses its reading stops draining, and the 12 h clock keeps
|
||||
running. A gap of many hours can therefore fail a drain that was working. The
|
||||
back-off then applies (7 days).
|
||||
- A charge whose reading is lost early (last SoC below target - 3) fails at the
|
||||
timeout, even if the pack was in fact filling. The same 7-day wait applies.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- **HOLD with no SoC**: closed by MAINT-15 (`MAINT-15-hold-ends-without-soc.md`).
|
||||
- It does not tell the operator why the reading is missing (sensor, register,
|
||||
link). It does not reuse the stale-input gate; it is the cycle's own rule.
|
||||
- The charge itself is still driven by the control loop, which has its own
|
||||
handling of a missing SoC (TEL-08 for the loop is a separate card).
|
||||
- A restart loses at most 5 min of accounting, as in MAINT-13. The "unknown for
|
||||
long" line may be said again after a restart: the episode start is in memory.
|
||||
- Text added is two log lines, English only, like the other log lines.
|
||||
@@ -0,0 +1,47 @@
|
||||
# MAINT-15 - the balancing hold ends on time with no SoC reading
|
||||
|
||||
**Status: for review.** Tests: `test_maint15.py`. No option added.
|
||||
|
||||
**The fault.** `step()` sent every tick with no SoC to `_no_soc()`, and for
|
||||
HOLD that returned 0 W without the time check. A hold that lost its reading
|
||||
never ended: `last_completed` was never written and the next due date never
|
||||
moved. Harmless for power (0 W), but the cycle was stuck. This was left open
|
||||
in MAINT-14.
|
||||
|
||||
## Rule
|
||||
|
||||
1. **HOLD ends at `hold_min` whether or not there is a reading.** One helper,
|
||||
`Maintenance._hold()`, holds the time check and is used by both paths. When
|
||||
the time is up it writes `last_completed`, goes IDLE and logs the same
|
||||
"cycle COMPLETE" line. Before the time is up it commands 0 W as before.
|
||||
2. **Text.** The 15-min "no battery level" line in HOLD now reads "The hold
|
||||
still ends at its normal time." Still once per episode.
|
||||
|
||||
## Why
|
||||
|
||||
HOLD is reached only after the charge counted as done. Every entry into HOLD
|
||||
is in `step()` or `_no_soc()` and follows a charge that reached the target,
|
||||
stalled near full (MAINT-13) or timed out near full (MAINT-13/14). Nothing else
|
||||
sets the phase to HOLD (`_enter(HOLD` has four call sites, all after a done
|
||||
charge). The hold is a wait for the BMS to balance; it never needed the level.
|
||||
So a hold that ends with no reading is a completed cycle. The "cycle COMPLETE"
|
||||
line is true without a reading: it names minutes of hold, not a level.
|
||||
|
||||
## Cost
|
||||
|
||||
- If the level was lost during the hold, the cycle is recorded as complete
|
||||
without anyone seeing the final level. The charge had counted as done, so this
|
||||
is the same trust MAINT-14 already gives a charge that ends with no reading.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- It does not check that the pack is still full at the end of the hold.
|
||||
- It does not say why the reading was lost.
|
||||
- With a reading, nothing changes. `test_maint15.py` section 7 compares the new
|
||||
HOLD tick by tick with a frozen copy of the release/1.0 HOLD branch (phase,
|
||||
setpoint, owner, events, `last_completed`) at four `hold_min` values. A wider
|
||||
trace of the whole cycle (800 seeded runs against db9e231) was run outside the
|
||||
repo; its script and log are kept under `scratch/MAINT-15/` of the dev
|
||||
workspace, not in this repository.
|
||||
- A state file written by an older version with `phase: hold` loads and ends on
|
||||
time; the file is not changed in format.
|
||||
@@ -75,7 +75,8 @@ P1 is its section 6 P1, and the pull request lists what was measured.
|
||||
P2's 19.33; Solar first + Cheap hours only 19.57.
|
||||
- Not done in P3: the forecast (P4), and a headroom too short for the run
|
||||
moving the rest to the next cheap periods.
|
||||
- OPT-15 (TEST-23 findings on 5a4cdc2, `test_price_run_fixes.py`):
|
||||
- OPT-15 (TEST-23 findings on 5a4cdc2, merged up to e3e4ba6,
|
||||
`test_price_run_fixes.py`):
|
||||
- F1, a charge stopped at a quarter edge and latched for the quarter. The
|
||||
P1 averager opens a quarter only when a sample arrives, and the HA source
|
||||
builds one 0.35 s after the reading, so the cycle on the boundary still
|
||||
@@ -84,6 +85,15 @@ P1 is its section 6 P1, and the pull request lists what was measured.
|
||||
projects the quarter `now` is in (`PeakTracker.project(roll=True)`,
|
||||
crediting the held sample as the averager will), and only a measured
|
||||
stop latches. Modes off still reads the old block (identity).
|
||||
Since SAFETY-91, `next_quarter()` does the same for the guard at two
|
||||
inverters (no stop there without the roll, same banked quarters); the
|
||||
roll is what covers one inverter, where the old projection stops the
|
||||
charge at every edge. With modes on at one inverter the roll also removes
|
||||
the 1 s 0 W command at each quarter edge that SAFETY-81's sim showed, so
|
||||
its modes-on digests are re-pinned (modes off equal to e3e4ba6). A
|
||||
rolled projection is not graded by SAFETY-81's alarm (the old edge tick
|
||||
read "no seconds left"), so a standing overload is still notified once
|
||||
per quarter.
|
||||
- F2, -1120 W export at a charge end against -257 W modelled. The replay
|
||||
acted every 5 s on readings of that instant, and by then the lagged
|
||||
battery had nearly arrived, so it never acted on a reading that still
|
||||
@@ -93,21 +103,81 @@ P1 is its section 6 P1, and the pull request lists what was measured.
|
||||
reaches the target (or `EDGE_HOLD_S`, 18 s; to 36 s while the battery
|
||||
still moves). The replay gained `Lag` (dead time, reading age, the P1
|
||||
debounce, 1 s cycles). Charge end, 800 W house: -10 to -51 W over eight
|
||||
lag variants; without the hold -1370 W (meter 2 s).
|
||||
lag variants; without the hold -1370 W (meter 2 s). On e3e4ba6 the same
|
||||
numbers hold. The hold gives the loop the target as its grid, so it
|
||||
yields to SAFETY-95's drain tail, and any other claim that moves the
|
||||
command ends it.
|
||||
- F3, a charge refusal in a cheap run was never probed: the SAFETY-73 pin
|
||||
stands only while the site asks that way, and nothing asked to charge.
|
||||
Probing was chosen over changing the card: the probe is 200 W for 34 s
|
||||
each 15 min under the same peak gates, and it wins back the run. In its
|
||||
probe window the refusing battery is a charger, pinned at 200 W by its
|
||||
own claim, and the others rest. At one inverter SAFETY-52 already ends a
|
||||
charge refusal as soon as the house asks for power.
|
||||
- Not fixed, same on 5a4cdc2: with lagged readings a headroom-sized quarter
|
||||
own claim, and the others rest. A monthly drain (SAFETY-78) still comes
|
||||
first, and with a day plan a probing Leftover solar battery goes only to
|
||||
its planned level. At one inverter SAFETY-52 already ends a charge
|
||||
refusal as soon as the house asks for power.
|
||||
- Not fixed, same on e3e4ba6: with lagged readings a headroom-sized quarter
|
||||
banks up to 1.4 W over the aim (48.6 W under the cap), and a battery
|
||||
reading older than the meter can make a charge start look like a house
|
||||
over the aim, a real guard stop.
|
||||
- Review: an unmeasured stop that never latched let a headroom missing
|
||||
every other cycle flip the charge 1799 times in 30 min, so the second one
|
||||
in a quarter latches (at most 4 changes a quarter). House steps of +3 and
|
||||
+5 kW during the hold, N=1 and 2: the peak guard's floor ends the hold at
|
||||
once, and no banked quarter differs from the loop without the hold by
|
||||
more than +33 W (1342 W, far under the aim).
|
||||
in a quarter latches (at most 4 changes a quarter). A house that rises
|
||||
1, 2 or 3 kW as the charge ends, from 30 s into the quarter to 15 s
|
||||
before its end (two inverters, lagged readings): the hold adds at most
|
||||
+33 W to that quarter against the loop without it, and the most any
|
||||
quarter banks is 3431 W with the charge sized to the aim (3450 W; the cap
|
||||
is 3500 W). The import during the hold is the rise, below the charge's
|
||||
own, and a rise past that is the peak floor's, which ends the hold.
|
||||
|
||||
## P4: the solar forecast and the day plan (2026-09-29)
|
||||
- Input: a Home Assistant forecast sensor (`pv_forecast_entity`, kWh left
|
||||
today; `pv_forecast_tomorrow_entity` optional), read by `app/solarfc.py`.
|
||||
Supported shapes: Forecast.Solar (state only), Solcast (`detailedForecast`)
|
||||
and Open-Meteo Solar Forecast (`wh_period`). The unit is read, not guessed;
|
||||
older than 3 h is stale (one missed hourly poll must not flag it).
|
||||
- Trust: `solar_trust_pct`, default 70 (owner answer 5).
|
||||
- House use: nothing the add-on recorded fitted. `tariff.db` holds grid
|
||||
import per quarter, which the batteries shape. So `dayplan.HouseProfile`
|
||||
keeps grid + battery per local hour for 7 days in the store
|
||||
(`house_profile`), median per hour. It is net of the solar the house used,
|
||||
so the solar sum never takes it below the night median. Solar readings are
|
||||
not used (TEL-11). The first plan needs one day of it.
|
||||
- Verdict (`dayplan.plan()`): trust x sum max(0, forecast - house) x 0.95
|
||||
until the expensive run the cheap run is for. Solar first takes it first.
|
||||
- Leftover solar may then charge from the grid up to min(ceiling, floor +
|
||||
the house's use in the expensive runs / 0.95), less its sun share: only
|
||||
the shortfall.
|
||||
- Cheap hours only ignores the plan and fills to the ceiling (design
|
||||
section 1; review of #156, see the replay below).
|
||||
- Solar first never charges from the grid (owner, 2026-09-29).
|
||||
- The level is kept unless it moves by min(1 kWh, 10 %). With no plan
|
||||
(no, stale or failed forecast, no house profile, no capacity) every mode
|
||||
is P3 option A exactly: `test_modes_p4.py` part 1 pins 12 digests from
|
||||
5a4cdc2 (modes on, with and without an unavailable forecast).
|
||||
- The plan is made with the runs (every 15 min, or at once when the forecast
|
||||
comes or goes). A lost forecast drops the levels at the next cycle.
|
||||
- Not done: the design's scaling by measured solar from 10:00 (it needs the
|
||||
solar readings TEL-11 keeps out), the HA `goodwe_<inv>_plan` sensor, and
|
||||
FCST-01.
|
||||
- Replay (`tools/opt11p4_replay.py`, 16 recorded days, Solar first + Leftover
|
||||
solar, net EUR, lower is better; site solar rebuilt from the recording,
|
||||
forecast errors from Elia's day-ahead Belgian solar forecast):
|
||||
- year-earlier hourly prices: P2 19.33, P3 option A 19.44, old one-period
|
||||
trade 18.14, P4 19.15 (perfect forecast 19.14, 1.5 x too high 19.16,
|
||||
missing 19.44);
|
||||
- the days' real 2026 quarter-hourly prices (held out): P2 32.26, option A
|
||||
32.01, old trade 31.40, P4 29.19 (perfect 29.21, too high 29.28, missing
|
||||
32.01).
|
||||
- Solar first + Cheap hours only, skipping its sun share (the first
|
||||
build): 19.57 (same as P3) and 29.72 against P3's 29.41. The shorter,
|
||||
moved runs left B lower, so later midday top-ups rested A while the sun
|
||||
shone. Cheap hours now ignores the plan, which is P3 exactly.
|
||||
- A forecast of no sun at all gives 19.14 and 29.33. So nearly all of the
|
||||
gain is Leftover solar buying the evening's shortfall in the cheap run;
|
||||
the forecast itself was worth 0.14 EUR in 16 September days.
|
||||
- Bias: the site's solar is rebuilt from the same net use the replay
|
||||
plays, and "recorded" keeps its hourly shape and adds only the national
|
||||
daily error. Both favour P4; "national" (no house leakage) gives 29.25.
|
||||
No threshold was tuned to these days. The 2026-09-24 PV recording could not
|
||||
be replayed: it is only in the live Home Assistant.
|
||||
|
||||
@@ -0,0 +1,79 @@
|
||||
# OPT-17 - the solar forecast from several entities, summed
|
||||
|
||||
**Status: for review.** Tests: `test_opt17.py`. Two options added.
|
||||
|
||||
A site whose forecast comes as several Home Assistant sensors (one per
|
||||
inverter or roof side) had to build a template sensor to sum them. Now each
|
||||
day can list them.
|
||||
|
||||
## Options
|
||||
|
||||
- `pv_forecast_entities` and `pv_forecast_tomorrow_entities`: lists of
|
||||
sensors, default `[]`, the same shape as `pv_entities`.
|
||||
- `pv_forecast_entity` and `pv_forecast_tomorrow_entity` are unchanged. An
|
||||
install that uses them needs no edit.
|
||||
- **Why new keys, not "string or list" in the old ones.** Measured on
|
||||
Supervisor 2026.08.0 by `tools/supervisor_shape_probe.py` §J, as TEL-12's
|
||||
§G did for `pv_entity`. Declared as a list, each forecast key refuses the
|
||||
string an install already stores (`Invalid list for option
|
||||
'pv_forecast_entity'`), and a `[]` default does not rescue it. The one
|
||||
spelling that takes both, `match(.*)?`, also takes the integer 417 and
|
||||
shows a plain text box, so a second sensor cannot be added in the UI.
|
||||
- §J also shows: a 0.17.0 blob validates unchanged with the lists at `[]`;
|
||||
the lists render as repeatable fields; a downgrade drops them and keeps
|
||||
the single keys.
|
||||
- `[]` in `options:` is load-bearing, as for `pv_entities`.
|
||||
|
||||
## Rules
|
||||
|
||||
1. **One key per day.** Setting the single key and the list for the same day
|
||||
is refused at start, with one message: keep the list, clear the single one.
|
||||
The list can hold that entity too. (TEL-12 lets `pv_entities` replace
|
||||
`pv_entity` with a caution row. Here the brief asked for a refusal: a
|
||||
doubled or dropped forecast changes what a battery buys, and no install
|
||||
has both keys yet, so the refusal breaks nothing.)
|
||||
2. **Each member in its own unit.** Every member is read as one forecast
|
||||
sensor is today (`solarfc._day()`): Wh, kWh or MWh, never guessed. Then the
|
||||
day's kWh are added up. A repeated id counts once.
|
||||
3. **One member not usable means the day is not usable.** Missing,
|
||||
unavailable, unknown, stale, not an energy unit, or a bad number: that
|
||||
day's sum is not used, exactly as when the single sensor reads that way.
|
||||
No today means no forecast (P3 option A). No tomorrow means today only.
|
||||
4. **Hourly split.** If every member has a split, the splits are joined
|
||||
(overlapping periods add up). If any member has none, the sum is spread
|
||||
over the bell, as for a state-only sensor.
|
||||
5. **Time.** The forecast is as old as its oldest member.
|
||||
6. **One read.** All members of both days are read in one gather, inside the
|
||||
gather that reads the inverters, so a slow sensor does not delay control.
|
||||
7. **Shown and logged once.** With two or more members, each one not usable
|
||||
is named on the status page by its place in the list (STYLE.md: no entity
|
||||
ids on the page), as a caution row titled "Solar forecast" on Home. The
|
||||
action log names the entity id, once when the set of failing members
|
||||
changes.
|
||||
8. **One member is the single key.** A one-member list reads, plans, shows
|
||||
and logs exactly as the single key with that entity.
|
||||
|
||||
## Why
|
||||
|
||||
- A partial sum is a smaller number that looks real. Two of three inverters'
|
||||
forecasts read as a duller day, and Leftover solar would then buy grid
|
||||
energy the sun was going to give. TEL-12 took the same rule for the same
|
||||
reason. No forecast is a known state with a tested fallback.
|
||||
- The bell for a mixed list: joining one member's hours with another's total
|
||||
has no honest shape, and the bell is the existing state-only rule.
|
||||
|
||||
## Cost
|
||||
|
||||
- One flaky member costs the whole day's forecast. A site with three
|
||||
sensors loses the plan more often than one with a template sum that hides
|
||||
gaps.
|
||||
- Two more options (85).
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- No weighting or calibration per member; FCST-01 is still the own forecast.
|
||||
- Members on different integrations with different refresh times: each must
|
||||
be fresh (3 h) on its own; there is no wait for a lagging one.
|
||||
- The day plan itself, the trust and the house profile are unchanged.
|
||||
- The Batteries screen still says only "no solar forecast now". The member
|
||||
is named on the status page.
|
||||
@@ -0,0 +1,80 @@
|
||||
# SAFETY-103 - no swing on old battery readings after a drain ends
|
||||
|
||||
**Status: implemented 2026-10-08, for review.** Tests: `test_safety103.py`.
|
||||
|
||||
**The defect** (SAFETY-95 rig test, check 5, F1). While a battery settles
|
||||
from its ended drain, SAFETY-95 steers on the house's point: grid + every
|
||||
battery's reading - aim. The meter is 1 s old; a battery register can be
|
||||
10 s old (the SAFETY-90 register model). At E+13 A's reading said 1238 W
|
||||
(6.8 s old) while A was at 616 W, so the house looked ~620 W bigger: B went
|
||||
860 -> 1650 -> 870 W. B's own old reading does the same the other way.
|
||||
|
||||
**The rule** (`main.py`, `_track_reads()`, `_drain_grid_w()`, N>=2, only
|
||||
while a drain's tail settles):
|
||||
|
||||
1. Each cycle, per battery: the range its power can be in. That is its last
|
||||
changed reading, widened by every command on its wire since (a lagging
|
||||
battery moves from one toward the others, never beyond). A new reading
|
||||
starts the range again.
|
||||
2. A reading that changed this cycle is taken as it reads. So is the side a
|
||||
battery refuses (SAFETY-73): it is not heading that way.
|
||||
3. The house point is held (first cycle: the loop's start from SAFETY-95).
|
||||
It moves only as far as the meter proves: to the nearest value of grid +
|
||||
the batteries' ranges - aim.
|
||||
|
||||
So the loop no longer moves on a reading that has not caught up. A real
|
||||
house step still moves it, as soon as the meter shows more than the
|
||||
batteries can explain.
|
||||
|
||||
**Why not the tester's rule** ("a battery whose reading is older than its
|
||||
last command counts at its command"). B's command changes almost every
|
||||
cycle, so B is almost always at its command. That is the plain meter, which
|
||||
chases A's tail: B swings 1420 W. A lag model needs the plant's time
|
||||
constant, which is not known for a client's inverter. Measured on the plant
|
||||
below (N=2, 1200 W, A Off; swing = a move of the others later undone):
|
||||
|
||||
| rule | 10 s lag | 5 s lag | 20 s lag | surplus, 5 s lag |
|
||||
|---|---|---|---|---|
|
||||
| release/1.0 (readings) | 760 | 840 | 150 | 800 |
|
||||
| tester's: at the command | 1420 | 1020 | 1600 | 800 |
|
||||
| lag model, tau 10 s | 70 | 140 | 80 | 580 |
|
||||
| lag model, tau 5 s, plant 20 s | | | 600 | |
|
||||
| hold all window | 0 | 0 | 0 | 0 |
|
||||
| **this rule** | **0** | **0** | **0** | **130** |
|
||||
|
||||
Holding all window ignores a house step: a 2 kW kettle at E+5 s imported
|
||||
14.4 Wh over the next 30 s (release 11.5, this rule 11.3); 2 kW more sun
|
||||
exported 16.9 Wh (release 8.5, this rule 8.9).
|
||||
|
||||
**Before -> after** (`test_safety103.py`, `tools/safety103_plant.py`: 800
|
||||
W/s ramp, 10 s lag, meter 1 s, registers 10 s at the rig's phases, B idles
|
||||
at -100 W; summed swing of the others in the 23 s after the end):
|
||||
|
||||
| case | release/1.0 | after |
|
||||
|---|---|---|
|
||||
| rig check 5: N=2, 1200 W, A Off | B 1140 -> 850 -> 1630 -> 870, swing 760 W | B holds 1140 W |
|
||||
| N=3, 1200 W / 4000 W, A Off | 680 / 630 W | 0 / 0 W |
|
||||
| solar surplus, N=2 / N=3 | 890 / 740 W | 130 / 130 W |
|
||||
| lag 5 or 20 s, registers 5 or 10 s, N=2 and N=3 | | at most 10 W |
|
||||
| registers as fresh as the meter (1 s) | | rows byte-identical |
|
||||
| refusal end | | rows byte-identical |
|
||||
| N=1, every end | | rows byte-identical (also against the release/1.0 tree) |
|
||||
|
||||
**Cost.** In the window, a house change smaller than what the batteries
|
||||
could still be doing is not followed until a reading catches up (at most a
|
||||
register period) or the window ends (23 s). Under a surplus the others
|
||||
still swing up to 130 W, a third of a slew step.
|
||||
|
||||
**Not covered.**
|
||||
- Outside the drain tail the loop steers on the meter; readings only reach
|
||||
the saturation freeze (SAFETY-96), unchanged.
|
||||
- A lost link or a refusal ends the tail at once (A is out of the split, or
|
||||
reads ~0 W). The swing after them is the loop's own on a lagging plant,
|
||||
the same with 1 s registers and on release/1.0: under a surplus up to
|
||||
1.5 kW at N=2 and 3.9 kW summed at N=3; after a lost link about 1 kW
|
||||
even without one. Not this card.
|
||||
- A battery that overshoots its command, or a reading offset beyond the
|
||||
range, can put the true power outside the range; the meter then moves the
|
||||
point, as before.
|
||||
- The end cycle's start (SAFETY-95 step 2) still uses the readings; the
|
||||
batteries were steady during the drain, so they are current there.
|
||||
@@ -0,0 +1,96 @@
|
||||
# SAFETY-107 - a refusal held under another writer is learned once
|
||||
|
||||
**Status: for review.** Tests: `test_safety107.py`. One inverter only; nothing
|
||||
changes at N>1 (SAFETY-73's unit refusal has no "another writer" end).
|
||||
|
||||
**The defect** (MAINT-13 F5, MAINT-14 "seen again"). A full pack under a
|
||||
maintenance charge in a cheap window takes no charge. At N=1 the action log then
|
||||
showed "BATTERY REFUSES asked -2500 W ..." and "BATTERY REFUSES ENDED: another
|
||||
writer" every cycle: 548 + 548 lines in 15 min on the MAINT-13 rig head,
|
||||
652 + 651 in 12 min on its base, 33 + 32 in 60 s in MAINT-14's c2b. The 40-line
|
||||
log flooded and the hint under the buttons changed every second, so the
|
||||
MAINT-13 notice was gone at once.
|
||||
|
||||
**Cause** (`main.py`, the SAFETY-52 block before `compute()`). The end tested
|
||||
`self.target != self.loop_w`: the wire differs from the loop's ask. A held
|
||||
refusal makes the loop ask 0 W, so any claim that binds (the maintenance
|
||||
charge's `hi`, the peak guard's `lo`, a trade's SET) differs from it on every
|
||||
cycle. The refusal was ended against the same writer it had been learned
|
||||
against. `sat_count` is not reset by that end, so `compute()` learned the same
|
||||
refusal again in the same cycle. Nothing about the battery or the wire had
|
||||
changed; only the log and the hint did.
|
||||
|
||||
**Other writers.** The same flap comes from any writer that holds the wire
|
||||
while the loop is refused, as long as the evidence lasts: a trade (a SET at
|
||||
P_ARBITRAGE) into a full pack, and the peak guard over an empty pack: 335
|
||||
refusal lines in 15 min each at a 5 s meter (`test_safety107.py` part 2, run on
|
||||
release/1.0).
|
||||
A maintenance drain or hold does not flap: its SET resets `sat_count` each cycle.
|
||||
|
||||
**The rule** (`_refusal_update()`, `rejudged`). When another writer held the
|
||||
wire, the held refusal is judged afresh: `compute()` gets `refused=0` and no
|
||||
probe, exactly as before the change. Then:
|
||||
|
||||
1. it finds the same refusal against that writer's ask: the same episode
|
||||
continues, with no line and no hint. The probe clock restarts, as it did on
|
||||
the old end and start: a probe is the loop's ask, and it is not on the wire
|
||||
while another writer is;
|
||||
2. it does not: the refusal ends, logged "another writer", or "the battery
|
||||
gives power" when the reading shows it (it was "another writer" before);
|
||||
3. it finds the other direction: end, then a new start, as before. In
|
||||
practice 2 comes first: SAFETY-94's evidence restarts when the ask changes
|
||||
sign, so a writer that turns round ends the refusal at once and the other
|
||||
way is learned ~12 cycles later (`test_safety107.py` part 3e).
|
||||
|
||||
**Why this rule.** The end now means what SAFETY-52 meant by it: the refusal no
|
||||
longer describes what is on the wire, judged by the same test that learns it.
|
||||
`compute()` sees the same inputs as before and the state after each cycle is
|
||||
the same (`batt_refused`, `batt_refused_at`), so every command is unchanged.
|
||||
Keeping the held refusal into `compute()` instead (mutation M5) would also
|
||||
stop the lines, but it holds the loop at 0 W where the old law let it ask past
|
||||
a writer's limit, which changes commands; it also removes SAFETY-52's
|
||||
owner-decided "another writer" exit.
|
||||
|
||||
**Evidence.**
|
||||
- Differential trace (`goodwe/scratch/SAFETY-107/probe/trace.py`, not in this
|
||||
repo; the real Controller in the CI image, release/1.0 bf3ac79 against this
|
||||
tree): 300 seeds, N=1 (153) and
|
||||
N=2 (147), 1/2/5 s meter, full/empty/dead/healthy battery windows, a stepping
|
||||
house, maintenance charge with the cheap window opening and closing, P1 and
|
||||
the peak guard, trade windows, stop/start; 427 680 cycles, 294 seeds with a
|
||||
refusal held. Every command, site target, integrator, `sat_count`, refusal
|
||||
state and reason is identical. Refusal lines: 100 748 before, 2 188 after.
|
||||
- The card's case: 1 line in 15 min at N=1 and N=2, 1/2/5 s meter, house
|
||||
importing or exporting (release/1.0: 335-1 753 at N=1; N=2 was already 1).
|
||||
|
||||
**Mutations** (`tools/mutation_run.sh` on purged copies; reds in
|
||||
test_safety107 / test_refusal / test_refusal_units; trace = seeds of 300 whose
|
||||
commands differ from release/1.0):
|
||||
|
||||
| | mutation | reds | trace |
|
||||
|---|---|---|---|
|
||||
| M1 | `now == rejudged` -> `False` (every such cycle ends: the old flap) | 26 / 0 / 0 | 0 |
|
||||
| M2 | `rejudged` always 0 (another writer never ends it) | 5 / 1 / 2 | 29 |
|
||||
| M3 | the probe clock is not restarted on a continued episode | 1 / 0 / 0 | 2 |
|
||||
| M4 | a probe may open while rejudged | 0 / 0 / 0 | 0 |
|
||||
| M5 | the held refusal goes into `compute()` while rejudged | 2 / 1 / 2 | 27 |
|
||||
| M6 | an end while rejudged always says "another writer" | 1 / 0 / 0 | 0 |
|
||||
|
||||
M4 is equivalent: a probe matters only if `compute()` engages in that call,
|
||||
which needs `SETTLE_CYCLES` saturated against the writer, and each of those
|
||||
cycles restarted the clock. The line stays because it states the rule.
|
||||
|
||||
**Cost.** None in power. A takeover by a different writer while the battery
|
||||
still refuses is logged as an end and, ~12 cycles later, a new start against
|
||||
that writer (3 lines for the episode, `test_safety107.py` part 3a).
|
||||
|
||||
**Not covered.**
|
||||
- A perfectly flat reading under a writer. The stale-reading gate trips, stops
|
||||
the site and seeds the refusal (SAFETY-52 decision 3). After the stop the
|
||||
writer's ask returns fresh, `compute()` has no saturation history against it,
|
||||
so the refusal ends at the first cycle and the next trip seeds it again: 2
|
||||
lines per gate cycle (29 in 15 min, house exporting), the same as release/1.0.
|
||||
The gate cycle itself (0 W, then the writer's ask) is the cause; stopping it
|
||||
changes commands. None of the rig runs showed it: real readings move.
|
||||
- At N=1 a refusal shapes only the loop. A writer above it still asks the
|
||||
battery; at N>1 SAFETY-73's P_SAFETY claim binds every writer.
|
||||
@@ -0,0 +1,98 @@
|
||||
# SAFETY-112 - control waits for Home Assistant to finish starting
|
||||
|
||||
**Status: for review.** Tests: `test_safety112.py`, `test_messages.py`.
|
||||
Control is unchanged. The add-on now says plainly that it is waiting.
|
||||
|
||||
## Cause
|
||||
|
||||
The Supervisor's proxy refuses every add-on request with 502 until Core's
|
||||
state is `RUNNING`. The add-on reads every battery reading and writes every
|
||||
power request through that proxy, so it cannot control until then. Readings
|
||||
that are already live inside Home Assistant do not help.
|
||||
|
||||
Source, Supervisor 2026.08.0 (the image the live site ran at CFG-04):
|
||||
|
||||
- `supervisor/api/proxy.py`, `APIProxy.api()` (REST, used for reads and
|
||||
`number.set_value`) and `APIProxy.websocket()` both start with
|
||||
`if not await self.sys_homeassistant.api.check_api_state(): raise HTTPBadGateway`.
|
||||
- `supervisor/homeassistant/api.py`, `check_api_state()` returns
|
||||
`state.core_state == "RUNNING" or state.offline_db_migration`. The state
|
||||
comes from Core's `/api/core/state`.
|
||||
- Upstream `main` has the same gate in both handlers (read 2026-10-13).
|
||||
- A Core restart restarts only the Core container
|
||||
(`homeassistant/core.py`, `restart()`). The add-on keeps running.
|
||||
|
||||
The add-on itself has no wait. Nothing in `app/` reads Core's state or waits
|
||||
for an event. The loop reads its inputs every second, a 502 gives `None`,
|
||||
and missing inputs give 0 W. P1 backoff is not involved: the live site reads
|
||||
the meter straight from the HomeWizard (`homewizard_local`), not through Home
|
||||
Assistant.
|
||||
|
||||
## Measured
|
||||
|
||||
Repro stack `safety112-*`, all removed afterwards:
|
||||
|
||||
- Home Assistant 2026.9.4, as live.
|
||||
- A test integration whose `async_setup` sleeps, so Core stays `NOT_RUNNING`.
|
||||
- A fake meter and two fake inverters that update every 2 s from load.
|
||||
- The Supervisor's own `APIProxy` and `HomeAssistantAPI` from the 2026.08.0
|
||||
image. Only the add-on token lookup, Core's access token and the container
|
||||
check are stubbed.
|
||||
- The add-on on `meter_source: homewizard_local` against a fake HomeWizard.
|
||||
|
||||
Times are seconds after `docker restart` of Home Assistant:
|
||||
|
||||
| run | Core `NOT_RUNNING` | entities live in HA | Core `RUNNING` | proxy 502 | first write | wait from live readings |
|
||||
|---|---|---|---|---|---|---|
|
||||
| base 3050fa5, N=2 | 13.1 | 17.1 | 253.1 | 0.9-252.7 (1 132 requests) | 254.7 | 237.6 |
|
||||
| base 3050fa5, N=1 | 13.1 | 18.1 | 256.1 | 1.5-255.1 (573 requests) | 257.2 | 239.1 |
|
||||
| this change, N=2 | 12.2 | 17.2 | 313.2 | 1.4-312.5 (1 406 requests) | 317.6 | 300.4 |
|
||||
| this change, N=1 | 12.2 | 17.2 | 255.2 | 1.2-254.1 (571 requests) | 257.1 | 240.0 |
|
||||
|
||||
The first write comes 1.0-4.4 s after `RUNNING`, so the whole wait is the
|
||||
proxy's. With a 400 s sleep Core moved on at 300.88 s on its own (bootstrap's
|
||||
stage timeout), so one slow integration holds a start stage for about 5
|
||||
minutes. The whole start can take longer: the live one took 414 s.
|
||||
|
||||
Before this change the page said "Not ready — Battery level: no usable
|
||||
reading", which sends the reader to Developer Tools for an entity that is
|
||||
fine.
|
||||
|
||||
## Rule
|
||||
|
||||
1. No way around the Supervisor. The add-on still talks to Home Assistant
|
||||
only through the proxy.
|
||||
2. While the proxy does not answer on the API (`hass.OUTAGE.waiting()`), the
|
||||
first status row is red: "Home Assistant is not answering, perhaps it is
|
||||
still starting. Control resumes by itself when it answers." The banner
|
||||
reads "Not ready — Waiting for Home Assistant to finish starting". The Home
|
||||
pill reads "Waiting for Home Assistant", in English and Dutch.
|
||||
3. A safety stop, a stalled control loop or shadow mode keeps its own banner
|
||||
and state over the wait, because none of them clears by itself.
|
||||
4. The log has one WARNING when Home Assistant stops answering, an INFO line
|
||||
every 5 minutes while it is down, and an INFO line with the length of the
|
||||
wait when it answers again.
|
||||
5. Only the API counts. The meter websocket alone does not, because the meter
|
||||
has its own row.
|
||||
|
||||
## Why it is safe
|
||||
|
||||
The change is text only. `cycle()`, the writes, the heartbeat, the stand-down
|
||||
on shutdown and every watchdog are untouched. `test_safety112.py` part 3 shows
|
||||
the same targets and writes with the flag on and off, for N=1 and N=2.
|
||||
|
||||
## Open, for the owner
|
||||
|
||||
The add-on cannot control while Home Assistant starts. These ways around it
|
||||
were not taken:
|
||||
|
||||
- **Talk to Core directly with a long-lived token** (`http://homeassistant:8123`).
|
||||
Core's own API answers while `NOT_RUNNING`. In the repro `/api/core/state`
|
||||
answered from 12-13 s, and a direct `number.set_value` 10 s into
|
||||
`NOT_RUNNING` returned 200 and set the value. The cost is a secret stored
|
||||
at every client site, which `hass.py` exists to avoid.
|
||||
- **Talk to the control board directly** (ESPHome native API), so control
|
||||
does not need Home Assistant at all. This is a large change.
|
||||
- **Remove the slow start at the site.** On 2026-10-12 the Solis
|
||||
integration's discovery held the start. Fixing or disabling it shortens the
|
||||
wait there, but not on a client site with another slow integration.
|
||||
@@ -69,6 +69,8 @@ which does not run the startup gate) the absence costs a shave and never a pack.
|
||||
|
||||
## 3. DECISION 2 — the site verdict is the MAXIMUM of the packs' own floors
|
||||
|
||||
*At N>=2 one pack at its floor no longer stops the others: [[SAFETY-87]].*
|
||||
|
||||
`Controller.pack_floor_soc` — the **minimum** measured SoC, the emptiest pack —
|
||||
**is unchanged**, exactly as the card instructed. What changed is the floor it is
|
||||
graded against. `peakguard.binding_soc_floor()` reduces the roster's per-pack
|
||||
|
||||
@@ -0,0 +1,43 @@
|
||||
# SAFETY-78 - a maintenance drain at two inverters
|
||||
|
||||
**Status: DECIDED 2026-09-29.** Fixes MAINT-05 §6 (OPT-11 P1 F1, UX-13 P3
|
||||
check 5, OPT-11 P3 F4). Tests: `test_safety78.py`.
|
||||
|
||||
**The defect.** At N>=2 the drain pins its pack (a unit SET at
|
||||
`P_MAINTENANCE`) and the site target is split around the pin. Whenever the
|
||||
site target was below the pin, the other pack had to charge. The allocator
|
||||
refuses opposite directions (SAFETY-25 §0a, SAFETY-31), so the site went to
|
||||
0 W and logged `ARBITER: REFUSED` every cycle. That covers a house below the
|
||||
drain rate, a grid-charge trade, and a house above it too: after a refusal the
|
||||
loop restarts from 0 W and its 400 W slew step is below the pin again.
|
||||
|
||||
**The fix.** While a pack drains at N>=2, main.py files a site limit
|
||||
`drain`, `lo` = what the pin really places (`allocator.pin_w()`: the drain
|
||||
rate inside that pack's own hard limits), at `P_MAINTENANCE`. So the site
|
||||
target is never below the pin and the other pack only adds power in the same
|
||||
direction. Opposite splits stay forbidden.
|
||||
|
||||
- The order is the arbiter's own: a safety SET (100) outranks the limit and
|
||||
the pin, so everything parks; the peak floor (50) and the drain floor are
|
||||
both applied, so the higher wins; a trade or the loop below the drain is
|
||||
lifted to it.
|
||||
- Below the drain rate the drained pack exports the rest, as the drain does at
|
||||
N=1 (`maintenance.py`: "forced discharge, exports the surplus"). Holding it
|
||||
to the house load would make N=2 drain differently from N=1; that is an
|
||||
owner question, not this fix.
|
||||
- A draining pack that can place nothing (a refusal, a stale link) adds no
|
||||
floor, and the wait is logged once per episode.
|
||||
- With battery modes on, no pack is a grid charger while another drains
|
||||
(`modetrade.decide(draining=)`, why `cycle`), and the other battery's card
|
||||
says why (`other_cycle`). Not while the drain waits: no floor is filed
|
||||
then, so the other battery may charge from solar.
|
||||
- Not filed at N=1, where the drain is the site SET itself: byte-identical
|
||||
(`tools/safety78_identity.py`, which hashes the claims too).
|
||||
|
||||
**Not changed (measured in the PR #154 review, follow-ups).**
|
||||
- At N=1 a drain (60) outranked the peak floor (50): a 5000 W house imported
|
||||
3000 W against a 2500 W limit. Fixed by [[SAFETY-83]].
|
||||
- At N=2 a maintenance CHARGE in a cheap window has the same stall: the
|
||||
charging pack's `hi = -floor` against the loop asking the other to give is
|
||||
refused on 141 of 261 cycles. The mirror fix is a site `hi`, which can meet
|
||||
the peak floor's `lo` (0 W), so it is not this card. Fixed by [[SAFETY-84]].
|
||||
@@ -0,0 +1,63 @@
|
||||
# SAFETY-81 — no false "Load too high for battery" alarms
|
||||
|
||||
**Status: 2026-09-29, owner go for the card. Review kept the 10 W tolerance
|
||||
as a constant and added the 10 s hold.**
|
||||
|
||||
## Defect
|
||||
|
||||
The SAFETY-79 test (SAFETY-79-test-report.md, F1/F2) saw 6 false alarms in 7.
|
||||
The alarm fired whenever `decide()` clamped its floor to the rating
|
||||
(`saturated`). Three things set that while the quarter landed on target:
|
||||
|
||||
- **Double count.** `decide()` sizes from the held meter reading plus the
|
||||
battery reading. When the meter sample predates the battery's last increase,
|
||||
the increase is counted twice. It happens under noise, and at each quarter
|
||||
start, where the battery is back while the held sample is still the spike.
|
||||
- **The aim, not the cap.** `saturated` is graded against cap − margin, so at
|
||||
margin 50 noise needs 50 W less to trip it (F2).
|
||||
- **Last seconds.** The gain 900 / remaining turns a few W over the aim into
|
||||
thousands of W wanted, with the battery far from its rating.
|
||||
|
||||
## Decision
|
||||
|
||||
The alarm needs `saturated` and `peakguard.load_too_high()`: with the battery
|
||||
at full power from now on, the quarter still ends more than `ALARM_MISS_W`
|
||||
(10 W) over the real limit (`ceiling_w`). That is the miss itself, without the
|
||||
gain. The battery reading it uses is the lower of this cycle's and the last
|
||||
one's. It must hold for `ALARM_HOLD_S` (10 s). At most one notification per
|
||||
quarter, because near the threshold the test flickers with the meter; the
|
||||
ERROR log line is written for every episode.
|
||||
|
||||
**Why 10 W:** at margin 0 the guard itself lands up to +5.7 W over (SAFETY-79
|
||||
test, check 5), and those misses are real but tiny; the alarm would fire in
|
||||
the last second of most guarded quarters. The margin (default 50) is the fix
|
||||
for them. Cost: a real miss of 10 W or less is not alarmed; at a capacity
|
||||
tariff of the order of EUR 50 per kW a year, 10 W in one month is cents.
|
||||
Review measured +13 W on a 10 kW two-unit site at margin 0, not saturated, so
|
||||
no alarm: the tolerance only matters when the battery is at its rating. A
|
||||
constant, not an option: `peak_margin_w` is the owner's knob.
|
||||
|
||||
**Why the hold (review):** the test assumes the load now lasts the rest of
|
||||
the quarter. A load over cap + battery for ~5 s every 30 s (`sine4500_fast`,
|
||||
a cycling hob or heater) alarmed at each quarter start while the quarter
|
||||
landed under the aim. The hold stops that.
|
||||
|
||||
**Cost:** a real alarm comes 10-12 s later than on 5a4cdc2 (`step6500` at
|
||||
1211 s, not 1201 s); a slow ramp 20 s later (`ramp6500`), as it waits for the
|
||||
real cap. While the battery refuses or its reading is lost, the alarm waits
|
||||
until the quarter is lost even at full battery (27-60 s later in review runs);
|
||||
those faults have their own alarms. A load over cap + battery for more than
|
||||
10 s still alarms even if the quarter later lands under. `ALARM_HOLD_S = 0`
|
||||
removes the hold.
|
||||
|
||||
## Not changed: the 1 s spike itself
|
||||
|
||||
The cycle after a quarter boundary and before the new quarter's first meter
|
||||
sample still sees 0 s left, files no claim, and an Off battery drops to 0 W for
|
||||
one cycle. That is the same edge tick as OPT-15 F1, so it is left to OPT-15.
|
||||
Control is unchanged here: every command in `tools/safety81_sim.py` is
|
||||
byte-identical to 5a4cdc2 (test_safety81.py part 1).
|
||||
|
||||
The double count also moves control, not only the alarm: on a late sample the
|
||||
guard asks for the full rating for one cycle (edge4600 at 902 s: 2000 W where
|
||||
1150 W holds the aim). Left to a follow-up card.
|
||||
@@ -0,0 +1,34 @@
|
||||
# SAFETY-83 - the peak guard outranks the maintenance drain at N=1
|
||||
|
||||
**Status: DECIDED 2026-09-29 (owner go, P1).** Follows SAFETY-78's "Not
|
||||
changed" list. Tests: `test_safety83.py`.
|
||||
|
||||
**The defect.** At N=1 the drain is the site SET at `P_MAINTENANCE` (60). The
|
||||
peak floor is a limit at `P_PEAK` (50), and clause 2 applies only limits at or
|
||||
above the winner, so the floor was ignored and the house imported what the
|
||||
drain left. A 5000 W house under a 2500 W limit and a 2000 W drain banked
|
||||
3000 W quarters; on the owner's settings (limit 3500, drain 2500, margin 50) a
|
||||
breach starts at about 5950 W.
|
||||
|
||||
**The fix.** While a drain owns the setpoint at N=1 and the peak floor asks
|
||||
for more than the drain rate, `main.py` (`_peak_over_drain()`) refiles that
|
||||
peak claim at `P_MAINTENANCE`. The arbiter then applies it: the target is the
|
||||
floor, still inside the safety limits, and a safety SET (100) still parks
|
||||
everything. Where the floor is at or below the drain rate nothing changes.
|
||||
|
||||
- The order in effect is now the same at N=1 and N=2: safety limits and the
|
||||
SAFETY-73 refusal > peak guard (with the SAFETY-79 margin) > maintenance >
|
||||
modes > trade > loop (`arbiter.py`, beside the priorities).
|
||||
- The drain keeps counting: the battery discharges at least the drain rate on
|
||||
every cycle, so the cycle is not reset or stalled; it only ends sooner.
|
||||
- Below the drain rate the rest is still exported (owner, 2026-09-29).
|
||||
- Identity: `tools/safety78_identity.py --diff` against 35cdffe changes only
|
||||
cycles where the guard asked for more than the drain; after such an episode
|
||||
the commands are identical again and only the log and the idle loop's
|
||||
integrator differ. N=2 is unchanged.
|
||||
|
||||
**Not changed.**
|
||||
- Between the drain rate and the peak aim, the house still imports what the
|
||||
drain leaves (N=1 behaviour kept by the identity). At N=2 the loop covers it.
|
||||
- A maintenance HOLD (0 W, 120 min, battery full) still outranked the peak
|
||||
guard at N=1. Fixed by [[SAFETY-86]].
|
||||
@@ -0,0 +1,46 @@
|
||||
# SAFETY-84 - a maintenance charge at two inverters
|
||||
|
||||
**Status: DECIDED 2026-09-30.** Follows SAFETY-78's "Not changed" list.
|
||||
Tests: `test_safety84.py`; identity: `tools/safety84_identity.py`.
|
||||
|
||||
**The defect.** In a cheap window the charging pack files its own
|
||||
`hi = -charge` (P_MAINT_SHAPE). At N>=2 the loop's site target sat above it
|
||||
(a house to cover, or its 400 W slew step from 0 W), so the other pack had to
|
||||
give while this one charged. The allocator refuses opposite directions
|
||||
(SAFETY-31), so the site sat at 0 W whatever the house
|
||||
(`tools/safety84_identity.py` on 9d5b7d1: 436 of 480 cycles refused). N=1
|
||||
was fine.
|
||||
|
||||
**The fix.**
|
||||
- While a pack's own limits make it charge at N>=2, `main.py` files a site
|
||||
limit `charge`, `hi` = what that pack's own `hi` places
|
||||
(`allocator.hi_w()`, whole W as the allocator rounds). The site target is
|
||||
never above it, so the other pack only adds power in the same direction.
|
||||
Opposite splits stay forbidden. Mirror of SAFETY-78's `drain` floor.
|
||||
- Peak guard first (owner order, SAFETY-83). The charge is sized to the
|
||||
quarter's headroom under the aim (`charge_headroom_w()`, cap or banked peak
|
||||
minus `peak_margin_w`), so it charges less instead of stopping: the meter
|
||||
sits on the aim and the guard does not need to step in. Where the house
|
||||
alone is over the aim the guard engages, the shaping is suspended as before
|
||||
(`shaping_suspended()`) and no `charge` is filed, so the guard's `lo` and
|
||||
this `hi` never meet in one cycle (no `lo > hi`, no park at 0 W).
|
||||
Without the headroom sizing the aim still held (the suspension did it), but
|
||||
a battery gave power back on 285 of 540 cycles at a 3000 W house
|
||||
(test_safety84.py part 2).
|
||||
- A site stop (a safety SET above P_MAINT_SHAPE) sizes the charge to 0 W:
|
||||
the unit `hi` is a hard limit, so a charge under a 0 W stop needs the other
|
||||
pack to give. It was refused, with an ARBITER line, on most cycles of the
|
||||
stop (test_safety84.py part 4). The stop still parked the site at 0 W.
|
||||
- A pack that cannot take the charge (a refusal, a full pack, a stale link)
|
||||
files no ceiling; the other pack follows the loop.
|
||||
- Not filed at N=1: byte-identical (`tools/safety84_identity.py`, which hashes
|
||||
every claim, in and out of a cheap window and under a banked peak).
|
||||
|
||||
**Not changed.**
|
||||
- At N=1 the charge is not sized to the headroom: the guard still suspends it
|
||||
and the battery gives until the quarter is safe. The same sizing would fit
|
||||
there; that is an owner question, not this fix.
|
||||
- Outside a cheap window (`hi = 0`, solar only) nothing is filed, at any N.
|
||||
- A HOLD (later fixed by [[SAFETY-86]]) and the "Battery is not keeping up"
|
||||
alarm (SAFETY-85) are untouched. In the identity runs that alarm's log line
|
||||
comes as often at N=2 as at N=1 (2 in 480 cycles).
|
||||
@@ -0,0 +1,91 @@
|
||||
# SAFETY-85 - no false "not keeping up" while another owner sets the battery
|
||||
|
||||
**Status: implemented 2026-10-01, for review.** Tests: `test_safety85.py`.
|
||||
|
||||
**The defect.** "Battery is not keeping up" (SAFETY-40, `goodwe_integrator_bound`)
|
||||
fired about every 2.5 min during maintenance (drain, charge, HOLD) and under the
|
||||
peak guard, while the battery gave exactly what it was told. Each warning
|
||||
re-created the HA notification. Rig counts: 24 in an hour (SAFETY-83 F1), 43 in
|
||||
7 episodes (SAFETY-86), 35 in 16 (SAFETY-87), 12 in 6 (SAFETY-84). The page
|
||||
counter counted cycles (861), not episodes.
|
||||
|
||||
**Cause, measured on the real Controller.**
|
||||
- N=1: when a higher claim decides, `cycle()` re-seeds the integrator from the
|
||||
target each cycle, then `compute()` adds `gain * error` for a grid error the
|
||||
loop does not own. Target + kick crosses the rail and sets `i_clamped`. The
|
||||
carried integrator is not wound (SAFETY-48 caps the lead at one slew step),
|
||||
so control comes back one slew step at a time.
|
||||
- N>=2: a maintenance pin is a unit claim. The loop stays the site winner and
|
||||
winds to its rail for watts the pinned battery may not give. When the pin
|
||||
lifts, the site jumps: 2500 W in one cycle when a HOLD ends under a 4500 W
|
||||
house, 1390 W when a charge pin lifts (`s84 n2_charge_dear`, t=1800 s).
|
||||
|
||||
**Decision.** Three rules; the alarm, its text and its id are unchanged.
|
||||
1. **The loop's clamp counts only on a cycle the loop decided.** The winner is
|
||||
the loop. Its number is on the wire, or only a rating (`device`,
|
||||
`supervised`) cut it. No bound held it, and nothing was unmet.
|
||||
(`Controller._loop_alarm_input`.)
|
||||
2. **A battery another owner set to discharge alarms when it gives less than
|
||||
it was told.** This covers every battery on a cycle the loop did not
|
||||
decide, and a battery with its own pin otherwise. The test is more than
|
||||
`saturation_w` short of the least it stood at over `SHORT_CYCLES` cycles
|
||||
and `SHORT_SPAN_S` (the plant's measured settle, SAFETY-13/73), for
|
||||
`saturation_cycles` cycles in a row (`clamp.delivery_short`). It covers a
|
||||
real shortfall during maintenance or under the peak guard. Before, that
|
||||
shortfall was silent unless the kick happened to reach the rail (house
|
||||
1000 W, drain 2000 W, battery gives nothing: 0 warnings before, 4 in 10 min
|
||||
now).
|
||||
3. **At N>=2, while maintenance holds a battery, the loop is bounded** by
|
||||
OPT-11's `loop_bound()` (what the batteries may place). It does not wind,
|
||||
and control comes back one slew step a cycle. Why maintenance only: that is
|
||||
where the jump was measured and where the owner order puts maintenance
|
||||
above the loop. Other N>=2 limits (pack cut-out, SAFETY-73 refusal) keep
|
||||
the old law. Rule 1 still silences them (the target is unmet), so they no
|
||||
longer warn either.
|
||||
|
||||
Fixing the windup was chosen over only ignoring the wound part, because at
|
||||
N>=2 the wound integrator moves real watts at hand-back. At N=1 there was
|
||||
nothing to fix: re-seeding already prevents windup.
|
||||
|
||||
**What SAFETY-03/40 protect is kept.** With the loop in charge, the integrator
|
||||
bound still warns (a runaway, a house above the rating), and a saturated
|
||||
inverter under the loop's own command still does not alarm (SAFETY-03 AC 2):
|
||||
rule 2 grades only batteries another owner set.
|
||||
|
||||
**The counter.** `ClampWatchdog.bound_episodes` counts episodes that had a
|
||||
bound engagement. The status row shows it ("N times since start").
|
||||
`bound` (cycles) stays for the log and the tests.
|
||||
|
||||
**Re-pinned digests.** Every change is intended; nothing at N=1 moves a watt.
|
||||
|
||||
| digest | what changed |
|
||||
|---|---|
|
||||
| s78 `n1_drain_owner` | the false clamp rows are gone from the log; commands identical |
|
||||
| s78 `n2_drain`, s84 `n2_charge`, `n2_charge_banked`, s79 `n2_maint` (test_peak_margin) | loop reason (`mode-bound`), integrator and loop claim while bounded; commands identical |
|
||||
| opt11 `n2_maint` (test_modes) | A drops out at t=1655 s: B follows the house at once, 8 cycles differ (max 920 W) |
|
||||
| s84 `n2_charge_dear` | A's pin lifts at t=1800 s: 400 W a cycle, not a 1390 W jump; the surplus step after it; 98 cycles |
|
||||
|
||||
test_safety86's "without the ceiling the log floods" now needs the ceiling
|
||||
and the bound both removed: either one alone keeps the loop inside what the
|
||||
batteries can give. The `alarmed()` helpers in test_safety84/86 also read
|
||||
SAFETY-81's quarter stamp, because ALLOCATOR rows can push its row out of
|
||||
the 40-row log.
|
||||
|
||||
**Review (PR #163).** The first draft graded each battery against last
|
||||
cycle's command and graded charges too. On plantsim's battery (10 s lag) at
|
||||
the live 2 s meter, every drain or charge start warned once, and an N=2 drain
|
||||
or HOLD under the peak guard with a stepping house warned 15 times an hour. A
|
||||
maintenance charge tapering near full warned 11 times in 50 min, which
|
||||
SAFETY-42 section 7 had ruled out. With the settle window and discharge only:
|
||||
0 in all of those cases. A battery that gives nothing still warns, lagging
|
||||
or not. At a hypothetical 20 s lag, it warns at most twice an hour. The cost:
|
||||
a battery that does not take a charge another owner set is not named by this
|
||||
alarm (the same gap SAFETY-42 states; the charge has its 36 h timeout).
|
||||
`test_safety85.py` part 7.
|
||||
|
||||
**Not changed, open for the owner.**
|
||||
- With the loop in charge and the house above the batteries' total rating,
|
||||
it still warns (SAFETY-40). On the rig's 2 x 2000 W N=2, most of SAFETY-84's
|
||||
count came from houses of 4500 and 6500 W.
|
||||
- TEL-10's `Loop reason` reads `mode-bound` while the maintenance bound holds
|
||||
the loop, with modes off. DOCS lists the value with both meanings.
|
||||
@@ -0,0 +1,47 @@
|
||||
# SAFETY-86 - the peak guard outranks the maintenance HOLD
|
||||
|
||||
**Status: DECIDED 2026-09-30 (owner).** Follows SAFETY-83's "Not changed"
|
||||
list. Tests: `test_safety86.py`.
|
||||
|
||||
**The defect.** The HOLD (battery resting full after the maintenance charge)
|
||||
is a SET of 0 W at `P_MAINTENANCE` (60), above the peak floor (`P_PEAK`, 50),
|
||||
so the floor did not bind. At N=1 a 6500 W house banked 6500 W quarters and
|
||||
'Load too high' fired (SAFETY-83 rig test, check 4). At N=2 only the other
|
||||
battery gave: 4500 W against a 3950 W aim (SAFETY-84 rig test, check 6).
|
||||
|
||||
**The fix** (`main.py`, `_peak_over_hold()`).
|
||||
- N=1: during a HOLD a peak floor above 0 W is refiled at `P_MAINTENANCE`, as
|
||||
for a drain (SAFETY-83). The battery gives the floor; the Why reads "raised
|
||||
for the peak limit".
|
||||
- N>=2: the holding battery's pin is raised to the floor minus what the other
|
||||
live batteries may place (their hard `hi`, or their pin). The others give
|
||||
first, the holding one only the shortfall. Why this split and not the
|
||||
allocator's shares: the hold is maintenance and outranks the others' use
|
||||
(owner order), and the owner rule for an Off battery is the same, "give way
|
||||
only for the shortfall". A battery Off by its mode (P_MODE, below
|
||||
maintenance) therefore still gives before the holding one.
|
||||
- N>=2, while the holding battery gives: a site `hold` ceiling at the floor
|
||||
(P_MAINTENANCE), so the loop does not ask for watts the hold keeps back.
|
||||
Without it the moving pin re-logged the ALLOCATOR "could not be placed"
|
||||
row each cycle and filled the action log (review, PR #161).
|
||||
- Below the aim nothing changes: the floor is 0 W, the hold is 0 W, the rows
|
||||
are identical to before (test_safety86.py part 2).
|
||||
- A site stop (a SET above `P_PEAK`) decides alone: nothing is raised at N>=2,
|
||||
and the refiled floor at N=1 stays under `P_SAFETY`. If another battery is
|
||||
pinned to charge (a SAFETY-73 probe) the pin is not raised, so the site is
|
||||
never split both ways.
|
||||
- The hold resumes by itself: the rule is evaluated each cycle, so when the
|
||||
guard lets go the command is 0 W again.
|
||||
|
||||
**The level dips below the target: the hold finishes anyway.** Owner
|
||||
decision 2026-10-01: the HOLD ends on its clock (`maintenance_hold_min`) even
|
||||
when the peak guard pulls the level down; no top-up. A top-up would re-enter
|
||||
CHARGE (up to 36 h, `CHARGE_TIMEOUT_MIN`) and keep the site's one maintenance
|
||||
slot meanwhile.
|
||||
|
||||
**Not changed.**
|
||||
- The peak guard still grades the emptiest battery (SAFETY-32): at N=2 with
|
||||
B under `peak_soc_floor` the floor is limited and A holds even when it is
|
||||
full (SAFETY-87).
|
||||
- "Battery is not keeping up" during maintenance (SAFETY-85), the N=2 charge
|
||||
flapping (SAFETY-88) and the N=1 charge headroom sizing are untouched.
|
||||
@@ -0,0 +1,83 @@
|
||||
# SAFETY-87 - the peak guard uses every battery that can still give
|
||||
|
||||
**Status: DECIDED 2026-10-01 (owner card).** Follows SAFETY-86's "Not
|
||||
changed" list. Tests: `test_safety87.py`; identity:
|
||||
`tools/safety87_identity.py`.
|
||||
|
||||
**The defect.** At N>=2 the guard graded the emptiest battery against the
|
||||
highest floor ([[SAFETY-32]] §3). One battery under `peak_soc_floor` made the
|
||||
whole site floor-limited: the claim asked for 0 W and the reserve alarm fired,
|
||||
even with the other battery full. Measured: a maintenance charge (A at 11 %)
|
||||
raised the alarm 10 times while both batteries gave 2000 W and the quarter
|
||||
landed on the aim (SAFETY-84 rig test, check 3); a HOLD (A at 99 %, B at
|
||||
15 %) left A at 0 W and banked 4051 W, raising the month peak (SAFETY-86
|
||||
review; rig case 7a: 4563.8 W).
|
||||
|
||||
**The fix.**
|
||||
- `decide()` and its call are unchanged. At N>=2 `Controller._peak_on_able()`
|
||||
then grades each battery on its own floor (`peakguard.reserve_split()`).
|
||||
One at or under it is *held*. The others that are live and not refusing
|
||||
(SAFETY-73) are *able*.
|
||||
- A floor-limited decision is re-taken on the able batteries
|
||||
(`peakguard.place_on_able()`): their own permission (min SoC against max
|
||||
floor, among them), and a floor of `min(need, able_w)`. `able_w` is their
|
||||
rating plus the drain a held battery gives anyway (its maintenance pin).
|
||||
- The held batteries weigh 0 in the split while the site gives
|
||||
(`arbiter.resolve(reserve=)`), so the floor lands on the able ones. During a
|
||||
HOLD, a held battery is not counted among the "others" (`_peak_over_hold()`),
|
||||
so the holding battery covers the need.
|
||||
- Floor-limited now means: some battery is held and the able ones cannot hold
|
||||
the aim. The claim still asks them for `able_w`. The alarm fires only if
|
||||
they miss the real limit at full power for `ALARM_HOLD_S`, the same test as
|
||||
'Load too high' (`_reserve_short()`), so a one-cycle miss at a quarter's end
|
||||
is not an alarm. With nothing able (all held, or the rest refusing or
|
||||
dropped) it is the old state: 0 W, immediate alarm.
|
||||
- The alarm and the row name `held`, each battery graded on its own floor. The
|
||||
old code named batteries against the site's highest floor.
|
||||
- Page: the two peak rows carry `runs`. A red `runs` row gives the banner its
|
||||
title without "Not ready", and the Home page is not shown as held at 0 W.
|
||||
Rows that do stop control still outrank it.
|
||||
|
||||
**How SAFETY-32's concern is still covered.** SAFETY-32 took min(SoC) against
|
||||
max(floor) so the guard never sizes a forced discharge a battery's own BMS
|
||||
stops. Now no battery at or under its own floor is asked for the peak: it is
|
||||
graded on its own floor, and an unread SoC or unknown cut-out counts as held.
|
||||
The min/max pairing still decides permission, over the able batteries. The
|
||||
roster verdict `decide()` echoes (`soc`, `soc_floor`) is kept, so SAFETY-32's
|
||||
call-site and reduction checks still bite. What changed is only that one held
|
||||
battery no longer stops the others. One exception, with battery modes on: see
|
||||
Open.
|
||||
|
||||
**Maintenance pins beside a held battery** (review). A draining battery that
|
||||
may still give is raised from its drain rate towards its rating for the peak
|
||||
floor, after the others (`_drain_over_reserve()`; peak > drain), else the
|
||||
floor's rest landed on the held battery. In a HOLD, a held battery counts its
|
||||
own pin (a drain) among the others, and a held battery pinned to charge stops
|
||||
the raise (never split both ways).
|
||||
|
||||
**Before -> after** (test_safety87.py, rig of 2 x 2500 W, aim 3450 W):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| charge, A 11 %, house 4500 | 3 reserve alarms, quarter 3450 | 0 alarms, 3450 |
|
||||
| HOLD, A 99 % / B 15 %, house 5500 | A 0 W, B 2488 W, 3 alarms | A 2054 W, B 0 W, 0 alarms, 3450 |
|
||||
| HOLD, house 6500 | A 0 W, B 2488 W, 4051 W | A 2500 W, B 0 W, 4014 W, 1 alarm (A alone is short) |
|
||||
| HOLD, month peak 4000, house 6000 | A 0 W, B 2488 W, 3551 W, alarms | A 2054 W, B 0 W, 3950 (peak - margin), 0 alarms |
|
||||
| both under the reserve | alarm | alarm (unchanged) |
|
||||
| N=1, every scenario | | byte-identical |
|
||||
|
||||
**Open, for the owner.**
|
||||
- The loop still draws a held battery (SAFETY-25 option A: the reserve binds
|
||||
the peak guard only). It gives last, after the able ones. So with house 6500
|
||||
in the charge case, B alone cannot hold the aim, the alarm fires as
|
||||
specified, and the loop then lands the quarter on the aim from A. The text
|
||||
says "cannot keep … alone", not "will go over", so it stays true.
|
||||
- Battery modes on, A Off and B held: when B alone can place the floor, OPT-11
|
||||
keeps A resting and B gives it. When B cannot, A gives first. Making Off give
|
||||
before a held battery in the first case needs a third allocator tier. The
|
||||
same at N=3: A Off, B held, C able, floor 4000 W gives C 2500, B 1500, A 0.
|
||||
Until then, with modes on, a held battery can give for the peak.
|
||||
- The notification and row text live in `messages.py`, which has no NL layer
|
||||
yet (UX-19). The Home page text, which has NL, is unchanged.
|
||||
|
||||
**Not changed.** N=1. 'Load too high' (SAFETY-81). SAFETY-85, -88, -89, -90.
|
||||
@@ -0,0 +1,81 @@
|
||||
# SAFETY-90 - the peak guard goes on after a P1 meter gap
|
||||
|
||||
**Status: DEV 2026-10-05, for review.** Tests: `test_safety90.py`.
|
||||
|
||||
**The defect.** A meter gap longer than `meter_max_age_s` leaves seconds the
|
||||
quarter average does not count (`p1.QuarterAverager`, on purpose: a guess must
|
||||
not reach the bill record). `peakguard.blindness()` then called the projection
|
||||
blind for the rest of the quarter, so the floor was 0 W. During a HOLD the
|
||||
battery gave nothing and the quarter went over: SAFETY-86 rig case 7b, N=2,
|
||||
3964.8 W against a 3450 W aim, the month peak raised; N=1, 3701 W (review).
|
||||
The page still read "Keeping the grid near zero". At start-up mid-quarter the
|
||||
same rule left the start-up quarter blind, and a held battery was drawn as last
|
||||
resort (SAFETY-91 test, O2).
|
||||
|
||||
**The fix** (`peakguard.fill_gaps()`, `peakguard.gap_w()`,
|
||||
`Controller._fill_peak_gaps()`).
|
||||
- Once readings are back, every second of a silence longer than
|
||||
`meter_max_age_s` counts at `gap_w = max(the limit, the import just before
|
||||
the gap, the import just after it)`, where "import" is the grid plus the
|
||||
batteries' discharge, i.e. with the batteries at 0 W. The gap's first
|
||||
`meter_max_age_s`, which the averager credits at the last reading, is topped
|
||||
up to `gap_w` too. The guard then grades the quarter as usual, so it is not
|
||||
blind and gives what keeps the quarter at the aim.
|
||||
- **The bound.** The count is at or above the true import as long as, during
|
||||
the gap, the house load (less solar) stayed at or under the higher of the loads seen just
|
||||
before and just after it, or under the limit, and the batteries did not
|
||||
start charging (during a gap they hold their last command, then go to 0 W).
|
||||
It never counts the gap below the limit. A load that rises above all three
|
||||
only inside the gap is the one case it can miss.
|
||||
- **Cost of the bound.** It is conservative: with the house at 6500 W, a 30 s
|
||||
to 5 min gap lands the quarter 100-180 W under the aim (table below), paid in
|
||||
battery energy.
|
||||
- **While the gap lasts** nothing changes: the reading is too old to steer by,
|
||||
the guard is blind (floor 0 W) and the "inputs missing" stop sets 0 W, as
|
||||
before.
|
||||
- **Before the first reading** (start-up or restart mid-quarter) the
|
||||
add-on was down, so the batteries were at 0 W (it sets 0 W when it stops,
|
||||
the ESP32 watchdog after 30 s). Those seconds count like a gap, at
|
||||
`gap_w(the limit, the import seen first)`; after a restart the restored
|
||||
reading's held `meter_max_age_s` is topped up the same way. The bound is
|
||||
the gap's, with only the "after" side known. A load the batteries cannot
|
||||
make up then raises "Load too high", which is true: that quarter is going
|
||||
over. The page says so: the status row "Peak guard: part of this
|
||||
15-minute period was not measured, counted as high use" and the home line
|
||||
"Part of this 15-minute period was not measured." / "Een deel van dit
|
||||
kwartier is niet gemeten." until the quarter ends.
|
||||
*Review:* the first version counted them at the aim, with "nothing is
|
||||
known" as the reason. The first reading does show the load, and with the
|
||||
batteries at 0 W the import was that load, not the aim: a 60 s restart
|
||||
during a 6500 W HOLD landed 3653 W against 3450 W.
|
||||
- The bill record (`quarter_blocks`) is unchanged: it still banks only what
|
||||
was measured. The estimate steers the guard and is never banked.
|
||||
- The action log gets one `PEAK_GUARD_GAP` row per gap, with the seconds and
|
||||
the watts it was counted at.
|
||||
- No option. The threshold is `meter_max_age_s`, the limit and the aim are
|
||||
`peak_cap_w` and `peak_margin_w`.
|
||||
|
||||
**Before -> after** (`test_safety90.py`, quarter as the meter really averages
|
||||
it, gap starting 300 s in; 10 s battery lag; aim 3450 W):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| N=1 HOLD 6500 W, gap 30 s / 60 s | 3456.6 / 5329.2 | 3346.2 / 3272.2 |
|
||||
| N=1 HOLD 5500 W, gap 5 min | 4717.9 | 3330.6 |
|
||||
| N=2 HOLD, B able, 6500 W, gap 30 s / 60 s | 3456.6 / 3865.6 | 3346.3 / 3272.7 |
|
||||
| N=2 HOLD, B able, 5500 W, gap 5 min | 3745.4 | 3288.9 |
|
||||
| N=2 HOLD, B held, 5500 W, gap 60 s | 3254.9, B drawn 2500 W | 3335.4, B 0 W |
|
||||
| gap across the edge, next quarter, N=1 / N=2 | 4100.0 / 3621.2 | 3446.3 / 3382.2 |
|
||||
| house 3000 -> 6500 W inside a 60 s gap, N=1 | 5255.6 | 3368.3 |
|
||||
| house 6500 -> 2000 W late in a 5 min gap, N=1 | 3629.2 | 3145.1 |
|
||||
| start-up 450 s in, N=1, house 5000 W (batteries at 0 W before it) | 5000.0 | 3450.0 |
|
||||
| restart, down 60 s / 150 s, N=1, house 6500 W | 4039.1 / 5483.3 | 3450.0 / 3450.0 |
|
||||
| meter never drops, N=1 and N=2 | | rows identical |
|
||||
|
||||
**Not changed.** The late-reading edge (SAFETY-91 test, O1): a reading late by
|
||||
less than `meter_max_age_s` is not a gap, and the seconds since it are not
|
||||
counted in the projection (on any quarter, not only after a gap). Near a
|
||||
quarter's end the 900/remaining gain turns that into a large negative excess
|
||||
and the floor drops for a cycle or more. Counting those seconds at the held
|
||||
reading would fix it, but it changes every quarter's last seconds on a
|
||||
healthy meter; it is handed back as its own card.
|
||||
@@ -0,0 +1,74 @@
|
||||
# SAFETY-91 - a held battery is drawn only after the others are full
|
||||
|
||||
**Status: DECIDED 2026-10-01 (owner: held battery last, SAFETY-25 option A
|
||||
kept).** Follows SAFETY-87. Tests: `test_safety91.py`.
|
||||
|
||||
**The defect** (SAFETY-87 rig test, F1 and F2). At N>=2 a battery at or under
|
||||
its own peak reserve was held back (weight 0) only on cycles where the peak
|
||||
guard asked for power.
|
||||
- F1: B draining at 1000 W, A held at 15 %, house 5500. Once the grid was
|
||||
near zero the loop set the target, A had its normal weight and B's drain
|
||||
pin bound, so the loop drew A at 2500 W for the whole quarter (15.0 ->
|
||||
10.7 %) while B stayed at 1000 W. In the next quarter A reached its
|
||||
cut-out, and B stayed pinned at the peak floor (~2422 W), not its 2500 W.
|
||||
- F2: in a HOLD (A holding, B held), at a quarter's edge the guard saw a block
|
||||
with no seconds left and asked for nothing for one cycle. The HOLD's
|
||||
ceiling lapsed, A went back to 0 W and the loop's target went to B: 2500 W
|
||||
for 1 s.
|
||||
|
||||
**The fix** (`main.py`, N>=2 only).
|
||||
- `_held_back()`: the batteries at or under their own reserve while another
|
||||
can still give (live, not refusing), graded as in `_peak_on_able()`. They
|
||||
weigh 0 in every split where the site gives, not only for the peak. With
|
||||
nobody able (all held, or the rest refusing or dropped) nobody is held back
|
||||
and the split is as before.
|
||||
Review: once held back, a battery stays so until its SoC reads more than 1
|
||||
point above its reserve. A reading flipping 20/21 % otherwise swapped
|
||||
~1000 W between the batteries on each flip (grid +-500 W with A 10 s and
|
||||
B 3 s lag). The guard's own permission (SAFETY-87) is unchanged.
|
||||
- `_drain_rise()`: while a battery is held back, a draining battery's pin
|
||||
becomes a floor at its drain rate (`lo`), so it rises towards its rating
|
||||
before the held one gives. Not for a held battery's own drain, not under a
|
||||
site stop, not for a battery that is not live.
|
||||
- `tariff.next_quarter()`: past a block's end, before the next block's first
|
||||
telegram, the guard grades the next quarter, projected from the held
|
||||
reading (the averager credits it there). Not when that reading is too old
|
||||
to be credited (`max_hold_s`).
|
||||
|
||||
**What stays.** SAFETY-25 option A: once every able or draining battery is
|
||||
at full power, the loop still draws a held battery (`allocator._fill()`'s
|
||||
last-resort pass). With house 5500 and 2 x 2500 W, A still gives 2500 W
|
||||
after B is full. Nothing is placed on a battery at its cut-out: OPT-09's
|
||||
pack limit closes it (`hi = 0`), and the drain rise lets B take the rest.
|
||||
|
||||
**Before -> after** (`test_safety91.py`, 2 x 2500 W, lagging battery 10 s):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| B drain 1000, A held, house 4000 | A 2500, B 1000 | A 1500, B 2500 |
|
||||
| same, house 5500 | A 2500, B 1000 | A 2500, B 2500 (option A) |
|
||||
| cycles A asked while B not full | 612 of 900 | 0 |
|
||||
| A at its cut-out, house 5500: B | 1572 W mean | 2500 W, A 0 W |
|
||||
| HOLD, late telegram at the edge | A 0, B 2470 for 1 cycle | A 2050, B 0 |
|
||||
| idle, A held, house 2000 | A 1005, B 1005 | A 0, B 2020 |
|
||||
| N=1, every scenario | | byte-identical |
|
||||
|
||||
**Why N>=2 only.** At N=1 there is no other battery to give first. The edge
|
||||
roll would also fix the N=1 one-cycle dip at a quarter's edge (SAFETY-86
|
||||
rig, "A dropped to 0 W for 1 s"), but this ticket keeps N=1 byte-identical;
|
||||
extending it is a one-line change for a later ticket.
|
||||
|
||||
**Re-pinned.** `test_modes.py` `n2` and `n2_off`: from t=1600 battery A is
|
||||
at its 20 % reserve, so B carries the house and A gives last (100 of 540
|
||||
cycles differ). With SAFETY-87's held rule both are a5dddad's again, and the
|
||||
test grades that.
|
||||
Two fixtures changed with it: `test_safety87.py` part 10's "without the
|
||||
raise" run also turns off `_drain_rise()` (else B rises anyway), and
|
||||
`test_peakguard.py` 10g and `test_watchdog.py`'s two-inverter rig give
|
||||
their second battery a cut-out, as rule 8 requires (an unknown cut-out is held, so A alone would carry the cycle).
|
||||
|
||||
**Not changed.** The peak guard's own rules (SAFETY-87). A drain with
|
||||
nobody held stays a pin (SAFETY-78). An Off battery beside a held one
|
||||
(SAFETY-87 Open). The first cycle after start, before any quarter is
|
||||
measured, can still put the loop's first step on a held battery in a HOLD.
|
||||
SAFETY-88, -89, -90, -92, -93, -94.
|
||||
@@ -0,0 +1,60 @@
|
||||
# SAFETY-93 - the maintenance charge end hands back smoothly
|
||||
|
||||
**Status: implemented 2026-10-02, for review.** Tests: `test_safety93.py`.
|
||||
|
||||
**The defect** (SAFETY-85 rig test, check 4; also on 9358781). At N=2, when
|
||||
A's maintenance charge ended, B went 0 -> -1600 W in one cycle and charged
|
||||
from the grid with the house at 6000 W. The HOLD end was already smooth
|
||||
(SAFETY-85).
|
||||
|
||||
**Cause.** During the charge the site target holds A's charge (SAFETY-84's
|
||||
`charge` ceiling, -2000 W). At the end A gets its HOLD pin (0 W), but the
|
||||
loop starts its next step from last cycle's site target. The slew limit
|
||||
moves the site total by 400 W (-2000 -> -1600), and the only battery left
|
||||
to place it on is B. The same happens when the charge times out or the
|
||||
battery is switched Off (A free, its -2000 W shared out). With the charge
|
||||
suspended by the guard and A giving under the loop, B took A's share in
|
||||
one step (675 W).
|
||||
|
||||
**The fix** (`main.py`, `_reseed_charge_end()`, N>=2 only). On the cycle a
|
||||
battery leaves CHARGE, the loop's start point (`self.target`, and the
|
||||
integrator with it) is what the other batteries stood at plus that
|
||||
battery's new command: its pin (HOLD or abort, 0 W), or, if it is free, its
|
||||
last discharge (a charge stops). The loop then moves from there one slew
|
||||
step a cycle. The ending battery's own step (-2000 -> 0 W) is maintenance's
|
||||
pin, as before; it lowers the grid import. The end is kept until the loop
|
||||
next runs, so a missed poll on that cycle (the input hold) does not lose it.
|
||||
|
||||
Review: a charge also ends, for the site, when the battery is still in
|
||||
CHARGE but can no longer be placed: a stale link or a refusal (SAFETY-73)
|
||||
drops it, and its -2000 W landed on B the same way (B 0 -> -1600 W at a
|
||||
1200 W house). So the end is noted after the unit claims are filed: a
|
||||
battery leaves the charge when it leaves CHARGE, is not live, or its own
|
||||
claims contradict. The guard suspending the charge (SAFETY-84) is no end.
|
||||
|
||||
Why a start-point reseed, and not a per-battery slew in the allocator: the
|
||||
jump comes from one stale number at one edge, the kind of edge SAFETY-73
|
||||
(`_unit_refusal_end`) and OPT-11 P3 (`_reseed_run_edge`) already reseed.
|
||||
The change stays at that edge; nothing else at N>=2 moves.
|
||||
|
||||
**Before -> after** (`test_safety93.py`, 2 x 2500 W, 10 s lag, 2 s meter):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| rig case: house 6000, A charges 2000 to the end | B 0 -> -1600, charges 4 cycles | B 0 -> 400 -> 800 ..., never charges |
|
||||
| house 1200 | B 0 -> -1600 (2800 W from the grid) | B steps of 400, never charges |
|
||||
| charge times out / A switched Off | B 0 -> -1600 | B 0 -> 400 |
|
||||
| guard suspended the charge, A gives 1825 | B step 675 W | B step 395 W |
|
||||
| missed poll on the end cycle | B 0 -> -1600 a cycle later | B 0 -> 400 |
|
||||
| A dropped mid-charge (stale link, refusal), house 1200 | B 0 -> -1600 | B 0 -> 400 |
|
||||
| N=1, both charge ends above | | byte-identical |
|
||||
|
||||
No pinned digest moved: the 46 digests of `tools/*identity*.py` (N=1 and
|
||||
N=2) are byte-identical to f3e409c; none of their scenarios reaches a
|
||||
charge end.
|
||||
|
||||
**Not changed.** The peak guard's floor still moves the site in one step
|
||||
when it engages (a house step, a quarter edge): the guard outranks the slew
|
||||
(owner order). A HOLD pin still drops the holding battery to 0 W at once
|
||||
and SAFETY-86 gives way to the others first. SAFETY-88 (charge flapping
|
||||
above the aim) is untouched.
|
||||
@@ -0,0 +1,102 @@
|
||||
# SAFETY-94 - a battery that lags or reverses is not frozen or refusing
|
||||
|
||||
**Status: implemented 2026-10-03, for review.** Tests: `test_safety94.py`
|
||||
(rig: `tools/safety94_rig.py`). Also closes SAFETY-58. SAFETY-74 stays open.
|
||||
|
||||
## The defects
|
||||
|
||||
1. **Stale-reading gate (SAFETY-37).** Its 35 s ran from the register's last
|
||||
change. After a rest that clock was already past 35 s, so the first read
|
||||
after a new command tripped it, before the register could answer. Live
|
||||
2026-10-03 (0.14.0, N=2): 17:39:16 B and 17:39:25 A (load ramp after a
|
||||
rest), 19:00:04 A (drain start), 21:21:22 B (drain -> charge). Each was
|
||||
1 s after its command; each register answered within 11 s. This is
|
||||
SAFETY-58's shape.
|
||||
2. **Refusal at N=1 (SAFETY-52).** `compute()` engaged after `SETTLE_CYCLES`
|
||||
frozen cycles if the reading was under 100 W at that moment. The frozen
|
||||
cycles include a reversal through the battery's lag. At a 1 s meter the
|
||||
12th cycle comes as a battery reversing out of a charge passes 0 W
|
||||
(SAFETY-85 rig, O1: "gave -20 W for 13 cycles"). The refusal then held
|
||||
0 W, the battery settled at 0 W, never gave 100 W, and waited for the
|
||||
15-minute probe. N>1 already required 22 s in the band, so it was safe
|
||||
at a 10 s lag but not at 20 s.
|
||||
|
||||
## What changed
|
||||
|
||||
- **The gate counts only time the register was asked to move**
|
||||
(`freshness.Freshness._oblige`). A read counts the time since the last
|
||||
read when, at that read, the command is 250 W or more and has moved 250 W
|
||||
from where it stood at the register's last change. A register change
|
||||
(or a SAFETY-57 release) restarts the count. A command flapping in and
|
||||
out of the ask still adds up (frozen register, 0/1500 W every 5 s: trip
|
||||
at 69 s). The conjunction, `MOVE_W` and `RELEASE_S` are unchanged.
|
||||
- **The bound is unchanged at 35 s and now means what its derivation
|
||||
says.** The floor was always "how long a healthy register takes to answer
|
||||
a command": 6 s plant + 10 s publish + 1 s read = 17 s. The band
|
||||
`[2 x 17, 0.5 x 75] = [34, 37.5]` holds. Live answers measured: 1.4, 3,
|
||||
6 and 11 s after the command.
|
||||
- **Refusal evidence is the same at every roster size**
|
||||
(`main.Controller._gave_nothing`, SAFETY-73's count moved into a method).
|
||||
The reading must stay under 100 W, one way, while asked over 200 W, for 12
|
||||
cycles spanning 22 s. At N=1 `compute()` gets this as `gave_nothing` and
|
||||
needs it on top of its own freeze test. `None` (compute alone) keeps the
|
||||
old law.
|
||||
- **The evidence restarts when the reading moves 50 W towards the ask**
|
||||
(`REFUSED_PROGRESS_W`). A refusing battery reads flat (-3/-4 W live). Live
|
||||
readings wander by under 25 W at rest. A first-order lag crossing the band
|
||||
gains 50 W in at most 0.4 tau, so it cannot fill 22 s unless tau > 54 s.
|
||||
This also covers B, whose reading is 100 W below its power.
|
||||
|
||||
## Bounds and worst-case catch
|
||||
|
||||
| fault | before | after | budget |
|
||||
|---|---|---|---|
|
||||
| register frozen, then asked to move | 0-35 s after the ask (often 1 s) | 35 s after the ask (+1 read) | SAFETY-37: 35 s, under the 75/85 s consumer holds |
|
||||
| register frozen at rest reading ~0 W | stale 1 s after the ask | refused or stale, 0 W within 23-35 s | the same |
|
||||
| refusing battery, 1 s meter, N=1 | 11-16 s | 22-28 s | SAFETY-73's 22 s span (+ one 10 s publish) |
|
||||
| refusing battery, 2 s meter | 22-28 s | 22-28 s | unchanged |
|
||||
| refusing battery, 5 s meter | N=1 35-41 s, N=2 41-55 s | N=1 40-45 s, N=2 50-55 s | 12 cycles = 55-60 s |
|
||||
|
||||
Rig: `test_safety94.py` part 3. A release after SAFETY-57 still exposes
|
||||
the held number for one 35 s window of asking, so 35 < 75 < 85 still holds.
|
||||
|
||||
## Before -> after
|
||||
|
||||
- Live replay (part 1): 4 trips -> 0.
|
||||
- Refusing B (its -100 W idle reading): see SAFETY-97.
|
||||
- Rig, 10 s lag, N=1 and N=2, 1/2/5 s meters, two register shapes, 48 runs
|
||||
(part 2): before 27 stale trips and 1 refusal, after 0 and 0.
|
||||
- Reversals, lag 10 and 20 s, 1 s meter (part 2): before N=1 6 stale / 3
|
||||
refused, N=2 6 / 1; after 0 / 0.
|
||||
- 16-day loop capture (`test_freshness.py` part 8): 93 trips -> 59. Trips
|
||||
answered within 20 s: 21 -> 1. Two of the removed trips were not quick:
|
||||
a register held 351 s under a command hovering at the 250 W travel edge
|
||||
(under 35 s of asking before it moved; survivor 2's shape), and a
|
||||
refusing battery the gate had caught only on a passing ramp (SAFETY-52's
|
||||
refusal covers it).
|
||||
|
||||
## SAFETY-58 and SAFETY-74
|
||||
|
||||
- **SAFETY-58 is fixed** by this change: its card asks for the clock to
|
||||
start with the obligation and for the bound to be re-derived. Both are
|
||||
done above. `test_freshness.py` survivor 5 is now graded as closed.
|
||||
- **SAFETY-74 is not fixed.** A battery capped at 300 W with a perfectly
|
||||
flat reading, 5 s meter, house stepping: 50 trips/h at N=1 and 80 at N=2
|
||||
before, 37 and 60 after. With +-1 W dither: 0. A flat reading under a
|
||||
command that moved is exactly what the gate is for; telling "limited"
|
||||
from "frozen" needs a second signal (the meter, or SoC).
|
||||
|
||||
## Known gaps
|
||||
|
||||
- ~~B's standby offset (-95 to -118 W at idle) puts a refusing B outside the
|
||||
100 W band, so a refusing B never latched (review F1: at N=1 new, at N=2
|
||||
as before).~~ **Fixed by SAFETY-97 in the same PR:** the band is centred
|
||||
on each unit's learned idle reading. `SAFETY-97-idle-offset.md`.
|
||||
- A command that asks only part of the time (a fraction d) is caught after
|
||||
35 s of asking, which is 35/d s of wall time (0/1500 W every 5 s: 69 s).
|
||||
SAFETY-30's per-unit check restarts when its command stops opposing the
|
||||
held reading, which a lapsing ask normally does, so 35 < 85 holds there.
|
||||
SAFETY-31's circulation check (75 s) ignores the command, so its margin
|
||||
holds only while d >= 0.47.
|
||||
- A register frozen under a command that stays near the 250 W travel edge
|
||||
is caught late or not at all (survivor 2).
|
||||
@@ -0,0 +1,69 @@
|
||||
# SAFETY-95 - a maintenance drain that ends hands back smoothly
|
||||
|
||||
**Status: implemented 2026-10-06, for review.** Tests: `test_safety95.py`.
|
||||
|
||||
**The defect** (SAFETY-93 review, O1). At N=2, when A's drain ended (A
|
||||
switched Off, say) with the house at 1200 W, B went 0 -> +1600 W in one
|
||||
cycle and exported. It is the mirror of SAFETY-93 on the drain end.
|
||||
|
||||
**Cause.** During a drain the site target carries A's drain floor
|
||||
(SAFETY-78, `drain`, 2000 W) above what the house needs. At the end A's
|
||||
command drops (pin, Off, abort, stale link, refusal), but the loop slews
|
||||
from last cycle's target (2000 -> 1600) and only B is left to place it.
|
||||
Under a solar surplus B gave 1600 W into the export.
|
||||
|
||||
**The rule** (`main.py`, `_reseed_drain_end()`, `_drain_grid_w()`, N>=2
|
||||
only). On the cycle a drain ends:
|
||||
|
||||
1. The start point is what the others stood at plus A's new command (its
|
||||
pin, else 0 W; a dropped battery is sent 0 W), as SAFETY-93 does.
|
||||
2. If the house needs more, the start is raised to the house's own point
|
||||
(live batteries' readings + grid - target, as `_reseed_run_edge()`),
|
||||
but never above last cycle's start. So the others cover the house at
|
||||
once and never take over the drain's export.
|
||||
3. While A settles (SAFETY-96's window: within the deadband, at most
|
||||
`PLANT_SETTLE_DOWN_S`), the loop's error is the house's point minus its
|
||||
start, not the meter. The meter still shows A's tail and the others'
|
||||
climb; chasing it sent B down and then up again.
|
||||
4. Then the loop moves one slew step a cycle.
|
||||
|
||||
A drain ends when its battery leaves DRAIN, is not live, its claims
|
||||
contradict, or it will not give (SAFETY-73's limit outranks the pin
|
||||
without a contradiction, so the refusal is read from the battery; +1 only,
|
||||
as `_held_back()`). Today a contradiction on a drain only arises through
|
||||
a refusal; the clause stays because a contradiction sends A 0 W, which is
|
||||
an end (tested directly). The end is kept
|
||||
until the loop runs (a missed poll). A dropped draining battery is this
|
||||
rule's, not `_reseed_drop()`'s. Order in one cycle: drop/rejoin
|
||||
(SAFETY-96), charge end (SAFETY-93), drain end (this) last; each moves the
|
||||
start by its own battery, and the drain end's raise reads the start the
|
||||
others left.
|
||||
|
||||
**Why not SAFETY-93's rule alone** (step 1, then slew). Measured on the
|
||||
same plant: at 1200 W the grid imports 849 W and B goes to -465 W
|
||||
(charging) while the loop chases A's tail; at N=3 and 4000 W it imports
|
||||
784 W where base imports 42 W, as the others give up A's share of the house.
|
||||
The house point keeps the grid at its aim; the cap at last cycle's start
|
||||
keeps it from exporting.
|
||||
|
||||
**Before -> after** (`test_safety95.py`, 2500 W batteries, 10 s lag, 2 s
|
||||
meter; base = the same tree with the change taken out):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| drain done / Off / timeout, N=2, 1200 W | B 0 -> 1600, +390 W commanded export, grid then +559 W | B 0 -> 1210, grid within 40 W of its aim |
|
||||
| the same, N=3, 1200 W | B, C 0 -> 800, grid +695 W | 0 -> 605, grid +39 W |
|
||||
| the same, solar surplus | B gives 1600 W into the surplus | B never gives; site moves 400 W a cycle |
|
||||
| refusal, N=3, 1200 W | B, C step 1020 W, +2000 W commanded export | step 20 W, +70 W |
|
||||
| N=3, 4000 W | others take A's share at once | the same (grid +1 W, base +42 W) |
|
||||
| abort (site zeroed by the operator) | climbs from 0, grid +669 W | climbs from 0, grid +16 W |
|
||||
| stale link (board watchdog 25 s) | | as base, but N=3 4000 W: grid +676 W (base +786) |
|
||||
| N=1, every drain end | | byte-identical |
|
||||
|
||||
`tools/opt11_identity.py` n2_maint moved on purpose (A's drain refused at
|
||||
1655 s; B stays at the house's 1420 W instead of 2500 W). Re-pinned in
|
||||
`test_modes.py`. The other 45 digests are byte-identical.
|
||||
|
||||
**Not changed.** The peak guard's floor still binds (arbiter, after the
|
||||
loop). Held batteries still give last; the idle clamp and the freeze test
|
||||
are as they were. A charge end (SAFETY-93) and a trade end are unchanged.
|
||||
@@ -0,0 +1,59 @@
|
||||
# SAFETY-96 - a battery the loop cannot move does not freeze it
|
||||
|
||||
**Status: implemented 2026-10-06, for review.** Tests: `test_safety96.py`.
|
||||
|
||||
**The defect** (SAFETY-93 rig test). At N=2 the saturation freeze compares
|
||||
the site target with the site sum of the readings. After A's link went
|
||||
stale, A was out of the split but its reading (-2000 W, still charging) was
|
||||
in the sum: "saturation freeze (800 W vs -1903 W)", B held at 1200 W for
|
||||
~236 cycles until the circulation trip. After a charge timeout or Off at
|
||||
6000 W the loop froze ~14 s at 800 W while A came out of its charge. At a
|
||||
drop, B also took A's whole share in one step.
|
||||
|
||||
**The rule** (`main.py`, `_held_out_w()`, `_reseed_drop()`, N>=2 only).
|
||||
A battery is held out of the freeze test, counted at its command instead of
|
||||
its reading, while:
|
||||
|
||||
- it is out of the split (writes refused for `LINK_STALE_S`);
|
||||
- its last write was refused (its board may have gone to 0 W on its own
|
||||
watchdog);
|
||||
- it settles after a step the loop did not make: a charge end (SAFETY-93:
|
||||
HOLD, timeout, Off, refusal, stale link) or a rejoin (then every battery,
|
||||
as the split is made again). Settling ends when its reading is within the
|
||||
deadband of its command, or after `PLANT_SETTLE_DOWN_S` (23 s, the
|
||||
measured plant settle).
|
||||
|
||||
Its real power is not lost and not counted twice: the meter sees it, and
|
||||
the loop follows the meter. Only the freeze stops reading it as the loop's.
|
||||
The freeze still fires on the other batteries' own lag and on unplaced
|
||||
watts.
|
||||
|
||||
At a drop the battery's share leaves the loop's start point, so the others
|
||||
take over one slew step a cycle. At a rejoin it enters at its reading.
|
||||
|
||||
**Not a drop.** A missing reading or a stale register stops the site
|
||||
(`inputs_ok`), as before. A refused battery (SAFETY-73) stays in the sum:
|
||||
it is asked ~0 W and reads ~0 W. A watchdog-stopped battery (SAFETY-02/30)
|
||||
is pinned at 0 W and stays in the sum. New: no refusal is learned on a
|
||||
battery whose writes are refused; its board going to 0 W is no refusal. Its
|
||||
count is kept, not reset, so a link that refuses 1 write in 3 does not hide
|
||||
a battery that really refuses (review).
|
||||
|
||||
**Before -> after** (2 x 2500 W, 10 s lag, 2 s meter; freeze cycles not
|
||||
about the remaining battery's own lag):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| A drops while giving, A holds 1200 W | 128, B steps 1210 W | 0, B stays |
|
||||
| A drops while charging, A holds -2000 W | 78 | 0 (circulation trip stays: 4 kW goes round) |
|
||||
| A drops while charging, board to 0 W | 5 | 0 |
|
||||
| A drops then comes back, A holds 1200 W | 46, grid +1.1 kW | 0, grid within 250 W |
|
||||
| charge timeout at 6000 W | 7, B held at 400 W | 0, B climbs |
|
||||
| A switched Off at 6000 W | 6, B held at 800 W | 0, B climbs |
|
||||
| N=1, N=2 with no drop | | byte-identical |
|
||||
|
||||
**Not changed.** At a rejoin the allocator splits again at once (A 0 ->
|
||||
1205, B 2410 -> 1205 W); the site total does not step. A battery that keeps
|
||||
charging on its own after its link drops still trips the circulation check
|
||||
(it is real circulation). A trade end (`_reseed_run_edge`) still starts
|
||||
from the full site sum.
|
||||
@@ -0,0 +1,118 @@
|
||||
# SAFETY-97 - "gives nothing" is graded against each battery's idle reading
|
||||
|
||||
**Status: implemented 2026-10-04, folded into PR #171 (SAFETY-94), for
|
||||
review.** Owner decision 2026-10-04: the band's centre is clamped to
|
||||
+-75 W (see Bounds). Tests: `test_safety97.py` (rig: `tools/safety94_rig.py`).
|
||||
Closes SAFETY-94 review finding F1.
|
||||
|
||||
## The defect
|
||||
|
||||
B's power reading (board B's `inverter_ac_power`, 0x0518) shows -95 to -118 W
|
||||
at idle: its standby draw (the GoodWe app shows 0 W). A's shows -2 to -4 W.
|
||||
Every "the battery gives nothing" test was `|reading| < 100 W`, so a refusing
|
||||
B sat on the band's edge and never latched:
|
||||
|
||||
- N=2: never caught, before or after SAFETY-94.
|
||||
- N=1: the old one-instant check caught it in 17-105 s; SAFETY-94's shared
|
||||
rule (12 cycles in the band in a row) never did (review probe, 1200 s).
|
||||
|
||||
## Design
|
||||
|
||||
- **Offset source: learned per unit** (`app/idle.py`, `Inverter.idle`). No
|
||||
new option: a required one is a setup step every client gets wrong, and an
|
||||
optional one is a second source to reconcile. An override can be added
|
||||
later if a site needs one.
|
||||
- **When it learns:** control runs; the unit is not refused (unit or site),
|
||||
stale or sign-tripped; its command has been within 50 W (`IDLE_ASK_W`) for
|
||||
120 s (`IDLE_QUIET_S`, 6 lags of 20 s). A refusing battery is asked more
|
||||
than 50 W, and while refused it does not learn, so its refusal cannot be
|
||||
learned as idle. A capped battery under a big ask is not sampled either.
|
||||
- **How:** the first value is the mean of 120 s of samples; then it follows
|
||||
drift with a 30 min time constant. A sample beyond 250 W (`IDLE_SAMPLE_W`)
|
||||
is dropped (a register held at a giving value). The band is centred on
|
||||
the value clamped to 75 W (`IDLE_MAX_W`; owner decision below).
|
||||
- **Restart:** saved per unit (`unit/<name>/idle_w`, on first learn and each
|
||||
5 W move) and restored, clamped to 250 W. Without it a battery refusing from the
|
||||
start is never quiet, so never learned, so never caught.
|
||||
- **Until learned the idle reading is 0 W**: the rule as it was.
|
||||
|
||||
## Not chosen: the GoodWe LAN integration's DC battery power
|
||||
|
||||
Both inverters also appear through HA's GoodWe integration (B:
|
||||
`sensor.kelder_dyness_battery_power`, 0 W at idle; found read-only on the
|
||||
live HA 2026-10-04). Pointing `batt_entity` at it removes B's offset by
|
||||
configuration, but:
|
||||
|
||||
- the band must be safe without it: other installs may not have it;
|
||||
- it is polled over UDP on the inverter's Wi-Fi, a second channel that can
|
||||
drop while the board keeps reading (HW-01 lost both once); a missing
|
||||
reading stops the site;
|
||||
- SAFETY-37's 35 s bound is derived from the board's 10 s publish; the
|
||||
integration's poll interval (believed 10 s, not checked here) and latency
|
||||
are not measured;
|
||||
- DC power is not 0x0518, which SAFETY-30/31/42 were measured against.
|
||||
|
||||
It stays an install choice to test on the rig, not a code change here. With
|
||||
it, the learned idle reading is simply ~0 W.
|
||||
|
||||
## Where it applies
|
||||
|
||||
Every test of "gives nothing / gives / takes" now uses `reading - idle`:
|
||||
|
||||
| check | change |
|
||||
|---|---|
|
||||
| shared refusal evidence `_gave_nothing` (N=1 and N>=2) | centred |
|
||||
| N=1 engage and end in `compute()` (`idle_w`, the site sum) | centred |
|
||||
| N=1 end in `_refusal_update` | centred |
|
||||
| N>1 unit end (probe answered, takes the other way) | centred; uncentred, B's idle -100 W read as "takes 100 W" and ended a charge refusal at once |
|
||||
| stale-path refusal (`_refusal_from_stale`, N=1 and N>1) | centred |
|
||||
| SAFETY-42 "parked" (small ask, gives nothing) | centred |
|
||||
| SAFETY-37 stale gate | unchanged: it grades register changes against command travel, not a level |
|
||||
| SAFETY-57 release | unchanged: it reads the command only |
|
||||
| SAFETY-30 per-unit sign | unchanged: opposition needs both over 250 W; B's 100 W idle cannot make or hide one alone |
|
||||
| SAFETY-42 shortfall | unchanged: B reads ~100 W short at every power, which errs towards reporting (report only) |
|
||||
|
||||
## Bounds: owner decision 2026-10-04 (review R1)
|
||||
|
||||
Band: `|reading - centre| < 100 W`, centre = idle clamped to +-75 W.
|
||||
|
||||
- **Why a clamp under the band.** A wrong idle reading (taught during a
|
||||
rest while the reading shows something else, e.g. a grid top-up of a unit
|
||||
held at 0 W, or restored onto a swapped inverter) more than about 100 W off
|
||||
hid every refusal on that battery, at N=1 and N=2; with the first +-250 W
|
||||
clamp the rig missed a refusing A whenever the error was 110-250 W. At
|
||||
+-75 W the band always keeps 0 W +-25 W, so a battery reading about 0 W
|
||||
while refusing is caught whatever was learned or restored, and a wrong idle
|
||||
cannot refuse a healthy 0 W battery (its ask is over 200 W).
|
||||
- **The trade-off.** Options: keep +-250 W (covers idle readings to about
|
||||
+-350 W, any 100 W mis-learn hides refusals); clamp to +-75 W (chosen);
|
||||
"old band or centred band" (rejected: a correct B would need to give 200 W
|
||||
to answer its 200 W probe).
|
||||
- **Cost.** A battery whose idle reading is beyond about +-170 W is centred
|
||||
at most 75 W out, so its refusal falls outside the band: it behaves as in
|
||||
0.14.0 (not caught by this rule). B (-95 to -118 W) reads 20-43 W from its
|
||||
clamped centre. B is caught across -150..+90 W of error in its idle
|
||||
reading; learned 110 W or more too high it is missed, as in 0.14.0 at N=2.
|
||||
- A frozen register is still caught by the stale gate at 35 s of asking.
|
||||
- Recovery from a wrong value needs quiet time: tau 30 min.
|
||||
|
||||
## Catch times (rig, refusing from 200 s after a 400 s rest, +-4 W)
|
||||
|
||||
| refusing | meter 1 s | 2 s | 5 s |
|
||||
|---|---|---|---|
|
||||
| A, N=1 | 28 s (before 28) | 28 (28) | 65 (65) |
|
||||
| A, N=2 | 28 (28) | 28 (28) | 110 (110) |
|
||||
| B, N=1 | 28 (never) | 28 (never) | 65 (never) |
|
||||
| B, N=2 | 24 (never) | 24 (never) | 60 (never) |
|
||||
|
||||
A at N=2 on a 5 s meter is 110 s here because the rig's grid goes flat once
|
||||
A is cut, so the loop cycles on the 15 s floor; the same run on the PR before
|
||||
SAFETY-97 gives 110 s. B restored after a restart, refusing from the start:
|
||||
24 s; with nothing saved: never.
|
||||
|
||||
## Before -> after
|
||||
|
||||
- Healthy B with its offset, SAFETY-94's four scenarios, N=1 and N=2, 1/2/5 s
|
||||
meters, both register shapes, idle learned or restored (96 runs): 0 stale,
|
||||
0 refused. Reversals, lag 10/20 s, idle restored: 0.
|
||||
- Live replay (SAFETY-94 part 1): 0 trips (the gate is untouched).
|
||||
Reference in New Issue
Block a user