SAFETY-93: the maintenance charge end hands back smoothly, with no grid charging at a high house
At N>=2, when a battery's maintenance charge ended, its watts stayed in the loop's start point and landed on the other battery (B 0 -> -1600 W in one cycle, charging from the grid at a 6000 W house). On the cycle a charge ends, the loop now starts from what the others stood at plus that battery's new command. N=1 and all identity digests unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1677,6 +1677,8 @@ While a full battery rests after its charge (the hold), it gives just enough
|
||||
to keep the 15-minute peak at that aim if the house needs it; with two
|
||||
batteries the other one gives first. The hold still ends on its clock
|
||||
(SAFETY-86).
|
||||
When a charge ends, the other batteries take over one slew step a cycle,
|
||||
and none starts charging from the grid (SAFETY-93).
|
||||
|
||||