SAFETY-78 review: card truth while the drain waits, more checks
- homeview: no "This one does not charge" while the draining battery waits (no floor then, so the other battery may charge from solar). - test_safety78: one wait line across a probe, a second episode logs again, the card while waiting, and a seeded sweep of the floor against every other claim (part 6). - DECISIONS: the wait case, and the measured N=1 peak and N=2 charge follow-ups. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -29,10 +29,16 @@ direction. Opposite splits stay forbidden.
|
||||
floor, and the wait is logged once per episode.
|
||||
- With battery modes on, no pack is a grid charger while another drains
|
||||
(`modetrade.decide(draining=)`, why `cycle`), and the other battery's card
|
||||
says why (`other_cycle`).
|
||||
says why (`other_cycle`). Not while the drain waits: no floor is filed
|
||||
then, so the other battery may charge from solar.
|
||||
- Not filed at N=1, where the drain is the site SET itself: byte-identical
|
||||
(`tools/safety78_identity.py`, which hashes the claims too).
|
||||
|
||||
**Not changed.** At N=1 a drain (60) still outranks the peak floor (50), so
|
||||
the peak guard does not add to a drain there. That is pre-existing and kept by
|
||||
the N=1 identity.
|
||||
**Not changed (measured in the PR #154 review, follow-ups).**
|
||||
- At N=1 a drain (60) outranks the peak floor (50), so the guard does not add
|
||||
to it: a 5000 W house imports 3000 W against a 2500 W limit, a 6000 W house
|
||||
4000 W. Pre-existing, kept by the N=1 identity.
|
||||
- At N=2 a maintenance CHARGE in a cheap window has the same stall: the
|
||||
charging pack's `hi = -floor` against the loop asking the other to give is
|
||||
refused on 141 of 261 cycles. The mirror fix is a site `hi`, which can meet
|
||||
the peak floor's `lo` (0 W), so it is not this card.
|
||||
|
||||
Reference in New Issue