DOC-5: tell installers to turn on the Supervisor Watchdog
checks / unit (pull_request) Successful in 8m41s
checks / unit (pull_request) Successful in 8m41s
Since SAFETY-61 a dead control loop writes 0 W and exits 70. The Supervisor restarts a stopped add-on only when the per-install Watchdog toggle is on, and it defaults to off. One step in DOCS.md "Before you start", with a pointer to the DECISIONS file. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
6e6527224a
commit
02a822af98
@@ -16,6 +16,11 @@ You need:
|
||||
- A T-CAN485 (ESP32) flashed with `firmware/goodwe-master.yaml`
|
||||
- A grid-power sensor already working in Home Assistant, updating every ~5–10 s
|
||||
|
||||
After installing, turn on **Watchdog** on the add-on's Info tab. A crashed
|
||||
control loop stops the add-on at 0 W, and the Supervisor restarts it only when
|
||||
Watchdog is on (it is off by default). See
|
||||
`DECISIONS/SAFETY-61-control-task-death.md`.
|
||||
|
||||
## The safety model, in short
|
||||
|
||||
The inverter **holds its last command forever** — it has no meter-timeout. So:
|
||||
|
||||