UX-09: Details link for current HA, "would" in shadow mode, plain terms
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and older. Slug from GET /addons/self/info, version from GET /info, hostname as fallback. - Shadow mode: the over-rating alarm and row say what would have been sent, the peak alarm no longer says the battery is giving all it can. - "controller" -> "the add-on" / "control". Settings named by their labels; four labels changed to match (Peak reserve, Battery level entity, Solar production ..., Reversed-sign solar entities). - Shadow banner and inverter link notes moved to messages.py and checked. - DOCS Notifications and Status page rewritten for home owners, with a "For installers" part each. Allowlist 168 -> 167. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
This commit is contained in:
@@ -1065,7 +1065,7 @@ check("...and the status page says the guard is off, and why, rather than "
|
||||
"'idle' or a green row - the same answer SAFETY-18 already gives on a "
|
||||
"transport that cannot see it", len(off_rows) == 1
|
||||
and ": off" in off_rows[0]["text"]
|
||||
and "meter source" in off_rows[0]["text"]
|
||||
and "Where the meter reading comes from" in off_rows[0]["text"]
|
||||
and "idle" not in off_rows[0]["text"]
|
||||
and not off_rows[0]["ok"] and off_rows[0]["warn"])
|
||||
|
||||
@@ -2487,7 +2487,7 @@ rows25 = [r for r in c25.checks() if r.get("id") == "peak_guard"]
|
||||
|
||||
def _row_scope(text):
|
||||
"""SAFETY-25 in messages.row_peak_reserve()'s words."""
|
||||
return ("Home use still discharges below the reserve" in text
|
||||
return ("Home use still draws the battery below it" in text
|
||||
and "down to the cut-out level" in text)
|
||||
|
||||
|
||||
@@ -2531,8 +2531,8 @@ def _says_scope(body):
|
||||
"""SAFETY-25 in messages.peak_reserve()'s words: the reserve binds the peak
|
||||
guard only, and home use goes on discharging below it to the cut-out."""
|
||||
return ("The reserve only applies to keeping the peak down" in body
|
||||
and "normal home use can still discharge the battery below it" in body
|
||||
and "down to its cut-out level" in body)
|
||||
and "normal home use can still draw the battery below it" in body
|
||||
and "down to the battery cut-out level" in body)
|
||||
|
||||
|
||||
print(f" notification body tail: ...{_body25[-180:]}")
|
||||
|
||||
Reference in New Issue