- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and older. Slug from GET /addons/self/info, version from GET /info, hostname as fallback. - Shadow mode: the over-rating alarm and row say what would have been sent, the peak alarm no longer says the battery is giving all it can. - "controller" -> "the add-on" / "control". Settings named by their labels; four labels changed to match (Peak reserve, Battery level entity, Solar production ..., Reversed-sign solar entities). - Shadow banner and inverter link notes moved to messages.py and checked. - DOCS Notifications and Status page rewritten for home owners, with a "For installers" part each. Allowlist 168 -> 167. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
This commit is contained in:
+190
-109
@@ -2805,123 +2805,170 @@ it.
|
||||
|
||||
## Notifications
|
||||
|
||||
Each Home Assistant notification this add-on raises has a short title, one
|
||||
sentence (a red alarm may use three), and a **Details** link to the add-on
|
||||
documentation that names the section below. This section holds what the
|
||||
notification leaves out. The wording rule is `STYLE.md` in the repository; the
|
||||
texts live in `app/messages.py`. Every notification keeps a fixed
|
||||
`notification_id`, so a repeat replaces the card instead of adding one.
|
||||
The add-on tells you about a problem with a Home Assistant notification. Each
|
||||
one has a short title, one to three sentences, and a **Details** link to this
|
||||
page. The link opens the add-on's Documentation tab. Look for the section with
|
||||
the same name as the notification title below. A repeat of the same problem
|
||||
replaces the notification rather than adding a new one.
|
||||
|
||||
| Title | Severity | id |
|
||||
|---|---|---|
|
||||
| Battery is not keeping up | warning | `goodwe_integrator_bound` |
|
||||
| Power request too high | alarm | `goodwe_output_clamp` |
|
||||
| Load too high for battery | alarm | `goodwe_peak_saturated` |
|
||||
| Battery stopped limiting the peak | alarm | `goodwe_peak_soc_floor` |
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` |
|
||||
In **shadow mode** the add-on makes every decision but sends nothing: every
|
||||
inverter stays at 0 W. Notifications then say what the add-on *would* have
|
||||
sent.
|
||||
|
||||
### Battery is not keeping up
|
||||
|
||||
The grid-following loop's integrator reached its anti-windup bound
|
||||
(`integrator_max_w`): the controller has been asking for more than the battery
|
||||
delivers for a while. This is SAFETY-40, and it is **not** a fault. No command
|
||||
went over the rating and control keeps running. Short spells after a big load
|
||||
or solar step are normal. If it keeps coming back, check that the battery
|
||||
follows its commands. The bound and the command of that tick are in the add-on
|
||||
log (WARNING, reason code `OUTPUT_CLAMP`). See *The winding-loop alarm* for the
|
||||
full story.
|
||||
The battery gives less power than the add-on asks for. This is normal for a
|
||||
short time, for example just after a large load switches on or the sun comes
|
||||
out. It is not a fault, and control keeps running. If it keeps coming back,
|
||||
check that the battery is switched on, and that it is not empty (when it should
|
||||
give power) or full (when it should charge).
|
||||
|
||||
### Power request too high
|
||||
|
||||
The controller computed a command above a limit, and the command was cut to that
|
||||
limit before it was written. The notification names what was asked, what was
|
||||
sent, and which limit cut it: the configured inverter rating (`max_w`), the
|
||||
inverter's own limit (the setpoint device's range), or the inverter rating on
|
||||
the loop side. Asked always comes first. This is a **software fault** (the old
|
||||
wording was "BUG SIGNAL"). It is not the inverter failing to follow a legal
|
||||
command, which is the saturation freeze and does not alarm. Control keeps
|
||||
running. Report it with the add-on log, whose ERROR line carries the reason code
|
||||
`OUTPUT_CLAMP` and the full figures. See *The winding-loop alarm*.
|
||||
The add-on worked out a power request above what is allowed, and cut it back
|
||||
before sending it. The notification shows what was asked and what was sent,
|
||||
and which limit cut it: the “Inverter rating” setting, or the inverter's own
|
||||
limit. In shadow mode it shows what *would* have been sent. Control keeps
|
||||
running. This should never happen, so it is a software fault: please send the
|
||||
notification and the add-on log to your installer.
|
||||
|
||||
### Load too high for battery
|
||||
|
||||
The capacity-peak guard (SAFETY-07) is asking for everything the inverter can
|
||||
discharge, and the running 15-minute average is still projected over the peak
|
||||
limit. That 15-minute period will set or raise the month's billed peak
|
||||
(capaciteitstarief). The controller is not at fault: the house load is larger
|
||||
than the inverter. Switching off load in the next few minutes is the only thing
|
||||
that still changes the bill. The projection and the watts are in the add-on
|
||||
log. See *The capacity-peak guard*.
|
||||
Your home uses more power than the battery can supply, so this 15-minute
|
||||
period will go over your peak limit and raise this month's peak. The battery
|
||||
is already giving all it can. This is not a fault. Switch off large loads,
|
||||
such as an oven, a car charger or a heat pump, for the next few minutes. In
|
||||
shadow mode the battery gives nothing, so this can happen with a much smaller
|
||||
load.
|
||||
|
||||
### Battery stopped limiting the peak
|
||||
|
||||
Two words in this notification are settings. The **peak reserve** is
|
||||
*Peak guard will not discharge below (%)* (`peak_soc_floor`). The
|
||||
**cut-out level** is *Battery cut-out level (%)* (`bms_soc_floor`), where the
|
||||
battery's own system stops discharging.
|
||||
The add-on stopped using the battery to keep your peak down, so this
|
||||
15-minute period will go over your peak limit and raise this month's peak.
|
||||
Switch off large loads for the next few minutes. The notification says why,
|
||||
and what to do:
|
||||
|
||||
The peak guard wanted to discharge to hold the 15-minute peak, but it may not go
|
||||
below the peak reserve (`peak_soc_floor`, SAFETY-24). It also stops when the
|
||||
battery level cannot be read, or when an inverter's cut-out level is not set,
|
||||
because the reserve is graded against it. So this 15-minute
|
||||
period will go over the peak limit and set or raise the month's billed peak.
|
||||
Charging from the grid stays blocked meanwhile. On a site with several inverters
|
||||
the notification names the battery at its limit (SAFETY-32): each battery is
|
||||
graded against its own cut-out level (`bms_soc_floor`), and raising the other
|
||||
batteries' settings will not change this one.
|
||||
- **The battery is at its peak reserve.** The “Peak reserve” setting keeps
|
||||
that much charge back from peak limiting. Lower it if you accept a lower
|
||||
battery level.
|
||||
- **The battery level cannot be read.** Check the “Battery level entity”
|
||||
setting and that sensor in Home Assistant.
|
||||
- **A battery cut-out level is not known.** Fill in “Battery cut-out level”
|
||||
for each inverter in the settings.
|
||||
|
||||
⚠️ **The reserve binds the peak guard only (SAFETY-25).** It is not a
|
||||
whole-battery reserve. Ordinary self-consumption has no such floor and goes on
|
||||
discharging below it, down to the battery's own cut-out level. See *What
|
||||
`peak_soc_floor` does not protect*.
|
||||
The peak reserve only applies to keeping the peak down. Normal home use can
|
||||
still draw the battery below it, down to the battery cut-out level, where the
|
||||
battery switches itself off.
|
||||
|
||||
### Inverters working against each other
|
||||
|
||||
Two inverters were pushing power into each other: one discharging while another
|
||||
charged (SAFETY-31). **The meter cannot see this.** The two flows cancel at the
|
||||
P1 meter, so the site reads idle while both batteries cycle through two
|
||||
conversion stages. Every other guard reads that net figure, so none of them
|
||||
fires. The add-on has **stopped control and commands 0 W on every inverter**.
|
||||
If the grid reading does not move after that, one inverter is no longer
|
||||
listening to the add-on; this has happened on this hardware, once for
|
||||
6 h 25 min. Switch the inverters off at the isolator. The alarm is latched: a
|
||||
Home Assistant or add-on restart does not clear it, and the card is raised
|
||||
again every 5 min until you start control on the add-on page. The watts and the time
|
||||
window are in the add-on log; the *Circulating* line on the status page shows the
|
||||
live watts. See *The circulating-power alarm*.
|
||||
With several inverters, one was charging its battery from another. Your meter
|
||||
cannot see this, because the two flows cancel out, but it wastes energy. The
|
||||
add-on has stopped control and set every inverter to 0 W. If the grid power
|
||||
does not change after that, switch the inverters off at the isolator. A
|
||||
restart does not clear this. Find out why, then start control on the add-on
|
||||
page.
|
||||
|
||||
### An inverter is not delivering
|
||||
|
||||
One inverter has stood well short of its share of the site target for longer
|
||||
than the hold time (SAFETY-42), while the others have not. No other check sees
|
||||
this. A unit at 0 W is absent rather than pushing the wrong way, so the per-unit
|
||||
sign check and the circulation check stay quiet. **Nothing is commanded
|
||||
differently.** The guard only reports: commanding an inverter that has stopped
|
||||
listening achieves nothing, and the only fallback the add-on has is
|
||||
all-or-nothing. The other inverters keep regulating, and the site is short by up
|
||||
to the missing unit's rating. Check, in this order:
|
||||
With several inverters, one gives much less power than it is asked for, while
|
||||
the others do. Nothing is changed: control keeps running, and the other
|
||||
inverters carry on. Check, in this order:
|
||||
|
||||
1. Is the inverter answering on RS485 at all?
|
||||
2. Is its battery colder or emptier than its configured cut-out level
|
||||
(`bms_soc_floor`) says? If so, that setting does not describe this battery.
|
||||
3. Is anything else writing to it?
|
||||
1. Is the inverter on and connected?
|
||||
2. Is its battery empty or cold? If it is emptier than its “Battery cut-out
|
||||
level” says, that setting does not match this battery.
|
||||
3. Is anything else controlling it?
|
||||
|
||||
The alarm is latched and survives restarts. Control is still running, so to
|
||||
clear it, press *Start / stop control* twice (stop, then start) once you know
|
||||
why. See *A unit that stops DELIVERING is a third fault again*.
|
||||
A restart does not clear this. Once you know why, stop and then start control
|
||||
on the add-on page.
|
||||
|
||||
### Meter reading may be stuck
|
||||
|
||||
The meter keeps answering, but its value has not changed for longer than the
|
||||
hold time while the command stands at the power limit (SAFETY-18). The loop is
|
||||
regulating against a number that has stopped moving. The age is still fresh, so
|
||||
no other guard stops it. This is an alarm only: control keeps running and keeps
|
||||
following the reading. Held for a whole 15-minute period, it can set the month's
|
||||
billed peak. Check the meter; if it is stuck, stop control on the add-on page.
|
||||
The limit and command figures are in the add-on log. See
|
||||
*The frozen-meter alarm*.
|
||||
The meter keeps answering, but its value has not changed for a long time while
|
||||
the add-on asks the battery for full power. That usually means the meter
|
||||
reading is stuck. Control keeps running and keeps following the reading, so a
|
||||
stuck reading can raise this month's peak. Check the meter. If it is stuck,
|
||||
stop control on the add-on page.
|
||||
|
||||
### For installers: notifications
|
||||
|
||||
This part is for installers. The texts live in `app/messages.py` and follow
|
||||
`STYLE.md`. Every notification keeps a fixed `notification_id`, so a repeat
|
||||
replaces the card. The full figures and reason codes are on the ERROR or
|
||||
WARNING line of the add-on log.
|
||||
|
||||
| Title | Severity | id | Card |
|
||||
|---|---|---|---|
|
||||
| Battery is not keeping up | warning | `goodwe_integrator_bound` | SAFETY-40 |
|
||||
| Power request too high | alarm | `goodwe_output_clamp` | SAFETY-03 |
|
||||
| Load too high for battery | alarm | `goodwe_peak_saturated` | SAFETY-07 |
|
||||
| Battery stopped limiting the peak | alarm | `goodwe_peak_soc_floor` | SAFETY-24/25/32 |
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` | SAFETY-31 |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` | SAFETY-42 |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` | SAFETY-18 |
|
||||
|
||||
**The Details link.** Home Assistant 2026.2 and newer show add-on pages at
|
||||
`/config/app/<slug>/documentation`; 2026.5 removed the old
|
||||
`/hassio/addon/<slug>/documentation`, which 2026.1 and older still use. At
|
||||
start the add-on reads its slug from `GET /addons/self/info` and the Home
|
||||
Assistant version from `GET /info`, and builds the link for that version. If
|
||||
the version cannot be read it uses the new path. If the slug cannot be read it
|
||||
falls back to the container hostname, and outside an add-on the line names the
|
||||
section without a link. The documentation tab adds no heading anchors, so the
|
||||
link cannot jump to the section.
|
||||
|
||||
**Battery is not keeping up.** The grid-following loop's integrator reached its
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40). No command went over the
|
||||
rating. The log line is a WARNING with reason code `OUTPUT_CLAMP`. See *The
|
||||
winding-loop alarm*.
|
||||
|
||||
**Power request too high.** A computed command above a limit was cut before it
|
||||
was written (SAFETY-03). The limits are `max_w` (label “Inverter rating”), the
|
||||
setpoint device's own range, or the rating on the loop side. Asked always comes
|
||||
first. The old wording was "BUG SIGNAL". It is not the inverter failing to
|
||||
follow a legal command, which is the saturation freeze and does not alarm. In
|
||||
shadow mode the clamp still grades the decision (SAFETY-10), so the alarm can
|
||||
fire while 0 W is on the wire, and the text says "would have sent". ERROR line,
|
||||
reason code `OUTPUT_CLAMP`.
|
||||
|
||||
**Load too high for battery.** The capacity-peak guard (SAFETY-07) asks for
|
||||
everything the inverter can discharge and the running 15-minute average is
|
||||
still projected over the peak limit, so the month's billed peak
|
||||
(capaciteitstarief) goes up. In shadow mode the guard's projection is made on a
|
||||
plant that did not respond (SAFETY-47), and the text says so. See *The
|
||||
capacity-peak guard*.
|
||||
|
||||
**Battery stopped limiting the peak.** The peak guard may not discharge below
|
||||
`peak_soc_floor` (label “Peak reserve”, SAFETY-24). It also stops when the
|
||||
state of charge is unread, or when an inverter's `bms_soc_floor` (label
|
||||
“Battery cut-out level”) is missing, because the reserve is graded against it.
|
||||
Charging from the grid stays blocked meanwhile. With several inverters the
|
||||
notification names the battery at its limit (SAFETY-32), each graded against
|
||||
its own cut-out level. ⚠️ **The reserve binds the peak guard only
|
||||
(SAFETY-25).** Self-consumption has no such floor. See *What `peak_soc_floor`
|
||||
does not protect*.
|
||||
|
||||
**Inverters working against each other.** SAFETY-31. The flows cancel at the
|
||||
P1 meter, so every other guard, which reads that net figure, stays quiet. This
|
||||
has happened on this hardware once for 6 h 25 min. The alarm is latched,
|
||||
survives restarts, and is raised again every 5 min until control is started.
|
||||
The watts and the time window are in the log; the *Circulating power check*
|
||||
row shows the live watts. See *The circulating-power alarm*.
|
||||
|
||||
**An inverter is not delivering.** SAFETY-42. The unit stood well short of its
|
||||
share of the site target for longer than `delivery_hold_s`. A unit at 0 W is
|
||||
absent rather than pushing the wrong way, so the per-unit sign check and the
|
||||
circulation check stay quiet. The guard only reports: commanding an inverter
|
||||
that has stopped listening achieves nothing. Check first whether it answers on
|
||||
RS485. The alarm is latched and survives restarts; stop then start clears it.
|
||||
See *A unit that stops DELIVERING is a third fault again*.
|
||||
|
||||
**Meter reading may be stuck.** SAFETY-18. The value has not changed for
|
||||
longer than `meter_freeze_s` while the command stands at the power limit, and
|
||||
the age is still fresh, so no other guard stops it. Only `meter_source:
|
||||
homewizard_local` can tell a silent meter from an unchanged value. The limit
|
||||
and command figures are in the log. See *The frozen-meter alarm*.
|
||||
|
||||
## The Web UI
|
||||
|
||||
@@ -2938,27 +2985,61 @@ exactly the three buttons it always had.
|
||||
|
||||
## Status page
|
||||
|
||||
The banner at the top says in one line what matters most now. Below it, the
|
||||
**Commissioning** list has one short row per check: ✓ green is fine, ! amber
|
||||
needs a look, ✗ red needs action. The rows name settings in words, never a Home
|
||||
Assistant entity id. The full figures of any alarm are in the add-on log, on the
|
||||
ERROR or WARNING line of that alarm. The texts are in `app/messages.py`.
|
||||
The add-on page shows a banner at the top and a **Commissioning** list below
|
||||
it. The banner says in one line what matters most now. Each row of the list is
|
||||
one check: ✓ green is fine, ! amber needs a look, ✗ red needs action. Rows name
|
||||
settings by their label, never by a Home Assistant entity id.
|
||||
|
||||
In **shadow mode** the banner says so first, whatever else is going on: the
|
||||
add-on makes every decision but the battery is not controlled, and every
|
||||
inverter stays at 0 W. If the banner is red and says a safety stop stays on,
|
||||
one of the red rows below is a stop that will still be there when shadow mode
|
||||
ends. That row says how to clear it.
|
||||
|
||||
| Row starts with | What it tells you |
|
||||
|---|---|
|
||||
| Controller | When the controller last ran. Red when it has stalled: the control board then sets the inverter to 0 W. |
|
||||
| Meter | The grid reading, its age, readings refused, and how long its value has not changed. |
|
||||
| Stuck-meter check | Whether the frozen-meter alarm can run. It needs the HomeWizard local source (`homewizard_local`), an inverter rating, and a power range the inverter can reach. *The inverter's own limit* means the setpoint device's range sets the threshold, below `max_w`. |
|
||||
| Meter reading may be stuck | The frozen-meter alarm is on. See *Meter reading may be stuck* under Notifications. |
|
||||
| *month*: peak … | This month's peak, and how close it is to the soft limit. |
|
||||
| Peak guard, Load too high, Battery at its peak reserve | What the capacity-peak guard is doing. *Peak guard: off* means `meter_source` is `off`, so there is no 15-minute average to guard. |
|
||||
| Battery level, Battery power, Grid power | The reading of that sensor. *No usable reading* means the sensor is missing **or** its reading is held back as too old (a separate stale-reading row then says so). Check it in Developer Tools before replacing it. |
|
||||
| Inverter control | The setpoint entity, and the power range the inverter accepts. |
|
||||
| Power request too high, Battery is not keeping up | The two loop alarms, each with its own count since start. After an episode clears, the count stays, ending in *fine now*. See *The winding-loop alarm*. |
|
||||
| Direction check, Site direction check | The sign checks (SAFETY-02/30). *Opposite for 12 of 60 seconds* counts toward a stop. When it trips, the inverter, or every inverter for the site check, is set to 0 W until you start control. |
|
||||
| Circulating power check, Inverters worked against each other | SAFETY-31, only with several inverters. |
|
||||
| Delivery check, *name* is not delivering | SAFETY-42, only with several inverters. |
|
||||
| Solar production | The PV reading. Sources are numbered in the order of `pv_entities`. The *reversed-sign list* is `pv_invert_entities`. A strongly negative reading by day means that source's sign is reversed. |
|
||||
| Control | When control last ran. Red when it has stopped running: the control board then sets the inverter to 0 W. |
|
||||
| Meter | The grid reading, its age, how many readings were refused, and how long its value has not changed. |
|
||||
| Stuck-meter check | Whether the add-on can warn you about a stuck meter. |
|
||||
| Meter reading may be stuck | See *Meter reading may be stuck* under Notifications. |
|
||||
| *month*: peak … | This month's peak, and how close it is to your peak limit. |
|
||||
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. |
|
||||
| Battery level, Battery power, Grid power | The reading of that entity. *No usable reading* means the entity is missing, or its reading is too old. Check it in Developer Tools before replacing it. |
|
||||
| Inverter control | Whether the inverter can be controlled, and the power range it accepts. |
|
||||
| *name*: … cannot be controlled, commands refused, “Setpoint entity” is not set | Whether each inverter still takes commands. |
|
||||
| Power request too high, Battery is not keeping up | See those titles under Notifications. Each shows how often it happened since the add-on started, and *fine now* once it has cleared. In shadow mode the row says what *would* have been sent. |
|
||||
| Direction check, Site direction check | Whether each inverter's power goes the way it is told. *Opposite for 12 of 60 seconds* counts toward a stop. When it stops, the inverter, or every inverter, is set to 0 W until you start control. |
|
||||
| Circulating power check, Inverters worked against each other | Only with several inverters. See *Inverters working against each other*. |
|
||||
| Delivery check, *name* is not delivering | Only with several inverters. See *An inverter is not delivering*. |
|
||||
| Solar production | Your solar production. Sources are numbered in the order of “Solar production entities, per inverter”. A strongly negative reading by day means that entity reads the wrong way round: add it to “Reversed-sign solar entities”. |
|
||||
|
||||
### For installers: status page
|
||||
|
||||
The texts are in `app/messages.py`. The full figures of any alarm are on its
|
||||
ERROR or WARNING line in the add-on log.
|
||||
|
||||
- **Stuck-meter check: off** needs `meter_source: homewizard_local` (label
|
||||
“Where the meter reading comes from”), a `max_w` (“Inverter rating”) and a
|
||||
power range the inverter can reach. *The inverter's own limit* means the
|
||||
setpoint device's range sets the threshold, below `max_w`.
|
||||
- **Peak guard: off** means `meter_source` is `off`, so there is no 15-minute
|
||||
average to guard.
|
||||
- **Battery level / Battery power / Grid power** are `soc_entity`,
|
||||
`batt_entity` and `meter_entity`. *No usable reading* is SAFETY-56: missing
|
||||
**or** held back as stale, and a separate stale-reading row then says which.
|
||||
- **Inverter control** is the `setpoint_entity` and the range it accepts.
|
||||
- ***name* cannot be controlled** (red): every write was rejected for
|
||||
`LINK_STALE_S`, so the unit is dropped and the others carry its share
|
||||
(DEV-02). ***name*: commands refused** (amber) is the same before that limit.
|
||||
***name*: “Setpoint entity” is not set** (amber): a roster entry nobody can
|
||||
write, so the site refuses to run at part strength and holds 0 W.
|
||||
- **Direction check, Site direction check** are the sign checks (SAFETY-02/30).
|
||||
**Circulating power check** is SAFETY-31, **Delivery check** SAFETY-42.
|
||||
- **Solar production** reads `pv_entity` or `pv_entities` (TEL-11/12). The
|
||||
*Reversed-sign solar entities* setting is `pv_invert_entities` (TEL-14).
|
||||
- **Shadow mode** (SAFETY-10): the banner turns red when a latch is up
|
||||
(circulating power, or a site or per-inverter sign trip), and that latch keeps
|
||||
its own red row.
|
||||
|
||||
## Status entities
|
||||
|
||||
|
||||
Reference in New Issue
Block a user